The sensor cable can be installed in three different ways. In-wall routing (Figure 4), surface-
mounted routing (Figure 5), and with appropriate covers plugging the sensor cable into the
cover (Figure 6).
i
The sensor cable must not be too long, because otherwise interference from other loads
and cables may occur. This may result in malfunctions. Therefore use only shielded cables,
and connect the shielding to earth. The total length must not exceed 20 m; avoid proximity
to other electrical facilities.
Connecting sensors to terminal block
i
If the sun and glass break sensor are used at the same time, an adapter must be used.
The adapter is connected to a cover with sensor evaluation or to the insert via the
3-pole terminal block. The adapter has two sockets for connecting the sensor plug.
Figure 3: Connection to the terminal block
o
Connect sensors as shown in connection diagram (Figure 3). The glass break sensor is
connected on the left and in the middle, and the sun sensor is connected on the right and
in the middle.
For the sensors, the "ground" is identified.
For the adapter and the extension cable, the "sun" is identified. The "ground" is the middle
cable.
i
Interchanging the connections will result in malfunctions.