Setting
Range
Preset
p01 Backlight
Darkest 1 - 3 Brightest
2
Adjusts LCD screen brightness low to high
p02 Mileage Unit
0:Mile , 1:KM
0
Changes mileage between imperial and metric
p03 Voltage Level (V)
24, 36, 48, 60, 64
48
Sets battery voltage - do not change
p04 Dormancy Time
0:None , 1-60 (min of inactivity)
10
Sets amount of inactivity time before the e-bike automatically turns o
p05 PAS Gears/Levels
0:3 gear mode , 1:5 gear mode:
1
Sets number of PAS levels available to use
p06 Wheel Diameter
Varies by protocol - see below
5
(5S): wheel diameter value: 0:16”, 1:18”, 2:20”, 3:22”, 4:24”, 5:26”, 6:700C, 7:28” (P2): wheel diameter in inches (0.1”
increments) range: 5.0 ~ 50 This parameter is linked to the speedometer and needs to be entered correctly
p07 Speed Magnet Number
1-100
6
This parameter is linked to the speedometer and needs to be entered correctly. Ordinary hub motor: the
number of magnetic steel is input directly. High-speed motor: it is also necessary to calculate the deceleration
ratio, and the input data = the number of magnetic steel × deceleration ratio.
p08 Speed Limit
(5S):1-41km/h, (P2):1-100km/h,
32
Adjusts maximum speed, increasing speed limit will not change maximum motor output
p09 Throttle Start Setting
0:zero start , 1:non zero start
0
Determines whether the throttle can be used without pedaling (zero start) or only while pedaling (non zero
start).
p10 Drive Mode
0:PAS Only 1:Throttle Only 2:Both
2
Toggles method to activate motor. GIO Electric Peak runs using both regardless of this setting
p11 PAS Sensitivity
Lowest 1-24 Highest
2
Adjusts PAS sensitivity The higher the setting the less PAS will engage. This will result in slightly longer battery
life.
p12 PAS Start Strength
1-5
5
Adjusts the strength the PAS engages in
p13
Power Magnet Disc Type
5, 8, 12
12
Sets power magnet disc type specific to the installed motor, do not change
p14 Controller Current Limit (A)
1-20
15
Sets amperage limit for controller, do not change
p15 Controller Undervoltage
39
Sets undervoltage for controller, do not change
p16 Odometer Reset
Hold
(
▲
)
for over 5 sec in p16
NA
Resets the total mileage accumulated on your odometer
p17 Cruise Control
0:Enabled , 1:Disabled
0
Toggles the ability to turn cruise control on/o
p18 Display Speed Ratio
50%-150%
100
Sets display speed ratio
p19 PAS Level 0
0:0 lvl , 1:no 0 lvl
1
Toggles on/o
the option of PAS lvl 0, allows for non powered use of the e-bike while still using lights, display
instruments etc. Throttle will not work on PAS lvl 0!
p20 Protocol
0:Protocol 2 1:5S Protocol
1
Sets the communication language for your e-bike, do not change! Please note certain parameters above have
specific setting options by protocol for either Protocol #2 (P2) or 5S Protocol (5S)