6. Operation

.22.

Selecting the “User-Def” menu will access to the following submenu (see Figure 6.12), 

Figure 6.12

Press the UP/DOWN keys to scroll through items. Press the ENTER key to edit the 

highlighted item. Press the UP/DOWN keys again to change the setting. Press the ENTER 

key to save the setting. Press the ESC key to cancel changes and returns to the previous 

menu.

       OV-V: 262V
       UN-V: 210V

OV-V: 240---270V

UN-V: 180---210V

OV-G-F: 60.3

62.0Hz(50.3---52.0Hz)

UN-G-F: 57.0

59.5Hz(47.0---49.5Hz)

Below is the setting range for “User-Def”. Using this function, the limits can be changed 

manually.

6.5.2 Grid ON/OFF

This function is used to start up or stop the power generation of Solis Single Phase 

Inverter (see Figure 6.13).

      Grid ON

        Grid OFF

Figure 6.13 Set Grid ON/OFF

Screens can be scrolled manually by pressing the UP/DOWN keys. Press the ENTER key 

to save the setting. Press the ESC key to return to the previous menu. 

6.5.3 Clearing Energy

NOTE: 

Please, set "Grid ON" to start up the inverter after the settings (refer to 
Section 6.5.2). Otherwise the inverter won't start up.

NOTE:

The " User-Def" function can be only used by the service engineer and 
must be allowed by the local energy supplier.

6.6 Arc fault(for AFCI version)

Solis Single Phase Inverter can integrate with AFCI module which can detect the arc in DC 

circuit. If arc fault happen, it can only be removed manually. 

During start up inverter will check AFCI module. If the check is OK, inverter will start 

normally. If the check is fail, LCD will show below:

Figure 6.16 AFCI check fail

       AFCI Check Fail

       Restart<ESC>

Press <ESC> for 3 seconds

, the inverter will restart. If the fault happen again, please turn

off inverter to restart. If the fault still happen, please contact us.

This function is used to set the new password for menu “Advanced info.” and “Advanced 

information” (see Figure 6.14).

Maintenance or replacement could clear or cause a different value of total energy. Use this 

function could allow user to revise the value of total energy to the same value as before. If 

the monitoring website is used the data will be synchronous with this setting automatically. 

(see Figure 6.15).

Press the DOWN key to move the cursor, Press the UP key to revise the value. Press the 

ENTER key to execute the setting. Press the ESC key to return to the previous menu. 

Enter the right password before set new password. Press the DOWN key to move the 

cursor, Press the UP key to revise the value. Press the ENTER key to execute the setting. 

Press the ESC key to return to the previous menu. 

6.5.3 New Password

6.5.4 Calibrate Energy

Figure 6.14 Set new password

Figure 6.15 Calibrate energy

YES=<ENT> NO=<ESC>

Password: 0000

YES=<ENT> NO=<ESC>

Energy:0000000kWh

6. Operation

Содержание Solis Series

Страница 1: ...Xiangshan Ningbo Zhejiang 315712 P R China Tel 86 0 574 6578 1806 Fax 86 0 574 6578 1606 Email info ginlong com Web www ginlong com Please record the serial number of your inverter and quote this whe...

Страница 2: ...ont Panel Display 3 2 LED Status Indicator Lights 3 3 Keypad 3 4 LCD 4 Installation 4 1 Select Location for the Inverter 4 2 Mounting the Inverter 4 3 Electrical Connections 5 Start Stop 5 1 Start the...

Страница 3: ...S Solis 5K 2G US Figure 1 2 Bottom side view DC Switch Water drill hole DC input AC input RS 485 Wiring box LCD display 4 buttons LED lights 6 Operation 6 1 Main Menu 6 2 Information 6 3 Settings 6 3...

Страница 4: ...WARNING WARNING symbol indicates important safety instructions which if not correctly followed could result in serious injury or death Improper use may result in potential electric shock hazards or b...

Страница 5: ...To startup the inverter the Grid Supply Main Switch AC must be switched on before the solar panel s DC isolator shall be switched on To stop the inverter the Grid Supply Main Switch AC must be switche...

Страница 6: ...talled in a confined space 9 NOTE Nothing should be stored on or placed against the inverter 300mm 500mm 500mm 300mm 300mm 300mm 300mm Figure 4 1 Inverter Mounting clearance 3 3 Keypad 3 4 LCD There a...

Страница 7: ...2 The steps to mount the inverter on the wall are given as follows 1 Locate the wall studs in the desired location and align the wall mount bracket over the studs Mark the mounting holes For masonry...

Страница 8: ...of the output voltage of PV array matches the DC and DC symbols Warning Before connecting inverter please make sure the PV array open circuit voltage is within the limit of the inverter Otherwise the...

Страница 9: ...on local requirement the inverter will start to generate power The green LED will be on continually and the LCD displays GENERATING WARNING Do not touch the surface when the inverter is operating It m...

Страница 10: ...n Menu Pressing the ENTER key locks Figure 6 2 a or unlocks Figure 6 2 b the screen 5 2 Stop the Inverter Figure 6 2 Locks and Unlocks the Screen of LCD b a 17 16 6 Operation 6 1 Main Menu During norm...

Страница 11: ...n Menu The screen will require the password as below The default password is 0010 Please press down to move the cursor press up to select the number 18 6 3 Settings The following submenus are displaye...

Страница 12: ...access the following options 1 Select Standard 2 Grid ON OFF 3 New Password 4 Calibrate Energy NOTE To access to this area is for fully qualified and accredited technicians only Please follow 6 4 to...

Страница 13: ...integrate with AFCI module which can detect the arc in DC circuit If arc fault happen it can only be removed manually During start up inverter will check AFCI module If the check is OK inverter will...

Страница 14: ...8 1 Alarm Message OV G V UN G V OV G F UN G F G IMP NO GRID OV DC OV BUS UN BUS GRID INTF INI FAULT OV TEM GROUND FAULT Failure description Over grid voltage Under grid voltage Over grid frequency Un...

Страница 15: ...Solis 1 5K 2G US 26 NEMA 4X 70 400Vdc THD 3 96 8 13 F 140 F 339W 657H 164D mm 13 3W 25 9H 6 5D inch 9 8kg 21 6lb CAN CSAC22 2 N107 1 UL1741 UL1998 UL1699B FCC part 15 Class B CAN CSAC22 2 N107 1 UL17...

Страница 16: ...4 for240V rated Solis 3 6K 2G US 29 2 2 2 2 THD 3 THD 3 97 5 97 5 339W 657H 172 5D mm 13 3W 25 9H 6 8D inch 15kg 33 1lb 15kg 33 1lb 339W 657H 172 5D mm 13 3W 25 9H 6 8D inch NEMA 4X 13 F 140 F NEMA 4X...

Страница 17: ...ed Solis 4K 2G US 30 THD 3 THD 3 97 8 97 8 339W 657H 172 5D mm 13 3W 25 9H 6 8D inch 17kg 33 1lb 17kg 33 1lb 339W 657H 172 5D mm 13 3W 25 9H 6 8D inch NEMA 4X 13 F 140 F NEMA 4X 13 F 140 F CAN CSAC22...

Страница 18: ...183 228 for208V rated 211 264 for240V rated Solis 5K 2G US 2 1 and 2 THD 3 97 8 17kg 33 1lb 339W 657H 172 5D mm 13 3W 25 9H 6 8D inch NEMA 4X 13 F 140 F CAN CSAC22 2 N107 1 UL1741 UL1998 UL1699B FCC...

Отзывы: