1.3 Attentions 

•  Keep the Electrocardiograph away from dust, vibration, corrosive

 

substances, explosive materials, high temperature and moisture.

•  If the Electrocardiograph gets wet, please stop operating it.

•  When it is carried from cold environment to warm and humid 

 

environment, please do not use it immediately.

•  Do not operate keys on front panel with sharp materials.

•  Do not have the product immerged in liquid.

•  When cleaning the device with water, the temperature should be lower

 

than 60°.

•  The design of the instrument is considered sufficiently with the safety 

 

requirement, but the observation of the patient and the instrument 

 

can not be ignored.

•  The instrument has normal useful life for five years since the first 

 

electrified use.

•  The instrument dose not have low-voltage alarm function, it only shows

 

the battery energy, please change the battery when the battery energy 

 

is used out.

2 OVERVIEW

Through the broading market investigation, our company assembles a lot 

of talents in the following majors: the appearance design of the product, 

structure design, transmission structure design, and circuit design, they 

produced ECG successfully after their deep research and reduplicate tests. 

This equipment adopts the thermal recording mode (the key point of thermal 

recording technique is the core component---thermal recording probe. 

The thermal recording probe is the high-tech component with advanced 

component integrated technology, integrating a large amount of heating 

elements (8points/millimetre) and its controlled circuit based on the ceramic 

basal body. It doesn’t have the false difference which caused by non- 

linearity, damping, and incongruence of pen warmth of the traditional hot 

pen ECG. In the frequency response which is the important index of affecting 

the descriptive authenticity, the product can reach 0.05-150Hz frequency 

response which is the world level, aslo the equipment has advanced digital 

baseline drifting filter, Alternating Current filter, and Myo- electricity 

disturbance filter. The sampling rate of lead signal is 800Hz, 

the closure frequency of low pass filter machine with guards against mixes 

folds is (-3dB) 220Hz. The sampling rate is higher than the standard of not 

lower than 500Hz which made by American AHA Association and European 

CSE Association.

ENGLISH

Содержание ecg80a

Страница 1: ...rs doivent lire et bien comprendre ce manuel avant d utiliser le produit ATENCI N Los operadores tienen que leer y entender completamente este manual antes de utilizar el producto M 33257 M Rev 0 12 1...

Страница 2: ...to the respective chapters for details Please read the Manual very carefully before using this equipment These instructions describe the operating procedures to be followed strictly Failure to follow...

Страница 3: ...4 TECHNICAL SPECIFICATIONS 7 5 ACCESSORIES 8 6 INSTALLATION 8 6 1 Sketch on each side and accessory 8 6 2 Electrode placement 9 6 3 Paper loading 11 7 OPERATING GUIDE 11 8 THE NOTICE OF THE BATTERY OP...

Страница 4: ...arth According the Standard IEC60601 this device is belonged to internal electrical power source CF applied part it is applied for cardiac examination This device is safe and reliable Please select th...

Страница 5: ...cture design transmission structure design and circuit design they produced ECG successfully after their deep research and reduplicate tests This equipment adopts the thermal recording mode the key po...

Страница 6: ...ECG waveform using thermo sensitive printer at the same time waveforms also can be frozen at any time It has manual and automatic modes to be chosen and Chinese English operation interface it is easy...

Страница 7: ...ulating equipment the silver and silver chloride chest electrode and heart electric conductance line of our company can be chosen If the defibrillating time surpassed 5 there needs to use disposable c...

Страница 8: ...relevant regulation according to IEC60601 1 One lithium rechargeable battery DC 7 4V lithium rechargeable battery The battery can keep on working for more than four hours when it is fully charged ECG...

Страница 9: ...29 Bottom View Back View 6 2 Electrode placement Advice Set the chest electrode first then the limb electrode 6 2 1 Elettrodo del petto AC Power Patient Cable Connector Battery Battery button ENGLISH...

Страница 10: ...cal gel coating should be separated and the touching chest electrode may result in short circuit 6 2 2 Limb electrode Place the electrode on the hand and leg clean the positions around to which limb e...

Страница 11: ...and protrudes 2cm in the top of the recording paper 7 OPERATING GUIDE 7 1 The instrument starts self checking after its turning on In the self checking process 7 2 The instrument will show the followi...

Страница 12: ...it will show NORM when the leads collecting signals normally and OVER when the leads fall off or the collected signals too big and results in system saturation 3 Leads state indication When the leads...

Страница 13: ...enu Interfaccia Inglese 1 Short menu Press to enter this interface Press to choose the relevant items and the item just turning then press button to set the information and then press to return 2 Cont...

Страница 14: ...glish Chinese etc Demo ON OFF choose ON in demo when it dose not need to be actual checked 8 THE NOTICE OF THE BATTERY OPERATING 1 This device includes hermetical chargeable lithium battery which need...

Страница 15: ...ot full The battery is only power supply and its power is exhausted The battery is charging 5 If the battery is full but the power of battery is exhausted within 10 minutes Please change new battery I...

Страница 16: ...ths Inspect and maintain of Lead electrode 1 The state of leads can be checked by multimeter please check the leads according to following list If the resistance between electrode and relevant insert...

Страница 17: ...e electrocircuit when the battery is over discharged 2 Check the AC power voltage The instrument has the function of protecting the electrocircuit when its overvoltage 3 Check AC interference check th...

Страница 18: ...ectrodes 2 Verify the electrode attachment and patient cable wire performance 3 Check the cleaning of electrode and patient skin Daub enough ECG medical gel on the electrodes and patients 4 Keep the p...

Страница 19: ...enough 5 The connection between patient cable and electrodes is not well 1 The batteries are drained 2 Patient moves 1 There is the filthy matter in the print head face 2 Paper problem 1 Checking ECG...

Страница 20: ...acknowledgment shortcut menu Function Key Pause On Function Key System Menu Function Key Print Function Key Calibrate AC power is on no battery or full of battery The battery solely powered and the b...

Страница 21: ...s product meets high qualitative standards both as regards the material and the production The warranty is valid for 12 months from the date of supply of GIMA During the period of validity of the warr...

Отзывы: