Gima D 351 Скачать руководство пользователя страница 9

                                                                                 Impulse sealer GIMA D 351

 

 

 7 

 

VII. 

MAINTENANCE  

 
 

 

        

  IT CAN BE EFFECTUATED ONLY BY TRAINED TECHNICIANS 

 
 

      

 

ALWAYS

 

UNPLUG THE POWER SUPPLY CABLE (n° 1 pict. 1) 

 
 
 
1)   machine opening procedure : 
 
            
To access top the inner components it is needed to remove the cover (n° pict. 2) of the machine. 
            Do as follows : 
 
 

         a) extract the cutter knob (n° 4 pict. 2) in vertical direction  

b)  unscrew the two rear screws (n° 4 pict. 1) and the two lower screws (n° 2 pict. 3)  
c)  Remove the cover (n° 3 pict. 2) of the pivoted plain , after to have unscrewed  its fixing  
     screws (n° 5 pict. 2) 

 

           

  

PAY ATTENTION TO THE CUTTER BLADE (n° 4 pict. 3)

 

 

d)  unthread in front , the cover from the machine  

 
 
 
2)   glass-PTFE protective cloth (n. 24 pict. 7) 
 
    The protective cloth could be damaged for normal use , for too long sealing time, or for the casual introduction  
    of any tools between the bars. 
  
    For the replacement proceed as follows: 
  

a)  set the pivoted plain  (n°3 pict. 6) on the max opening using the adjustment opening bars ball  

     grip (n°1 pict. 3) located underneath the base of the machine, loosen its locknut. 

                 b)     unscrew and remove  the two screws (n° 1 pict. 6)  
                 c)     extract the lower sealing bar (n° 8 pict. 2) from the machine  

      To work more softly , unplug the two power supply cable (n° 30 pict. 7) from the tails of the bar.  

d)   replace the old cloth with a new one. The original spare clothes have adhesive bands to facilitate the       
         application     

 
 

 

 

 

It is very important that the bags do not make any crumples  

 
 

e)  fit back the sealing bar proceeding on the contrary.   
f)  before tighten the two screws (n. 1 pict. 6 ), be sure that the bar perfectly leans on its own 

     stands (n° 2 pict. 6) 

 

 
 
 

Содержание D 351

Страница 1: ...D 351 IMPULSE HEAT SEALER v 1 5...

Страница 2: ...USE page 4 VII MAINTENANCE page 7 VIII LIST OF THE INTERNAL PARTS page 12 IX ELECTRICAL DIAGRAMS 230 Vac page 13 X LIST OF THE SPARE PARTS FOR THE NORMAL MAINTENANCE page 14 XI LIST OF THE SPARE PARTS...

Страница 3: ...the sealing area anything except the bag to be sealed Do not introduce in any opening of the heat sealer machine metallic objects to avoid electrical shocks To guarantee a constant and regular functio...

Страница 4: ...0V 50 60 Hz mono phase Max absorption 900 W only during the sealing Dimensions width mm 439 height mm 175 dept mm 311 Weight Kg 18 CONSTRUCTION AS PER CEI EN 60204 1 RULES IV INSTALLATION Use the mach...

Страница 5: ...ntification data plate 2 main switch 4 rear cover fixing screws 5 pivoted plain pict 2 1 cover 2 spool rolls 3 pivoted plain cover 4 cutter knob 5 pivoted plain cover fixing screws 6 pivoted plain kno...

Страница 6: ...right value according to the bags to seal see SUGGESTED SEALING TIME Introduce the mouth of the bag between the bars to let a free edge quite mm 20 over the seal Through the pivoted plain knob n 6 pic...

Страница 7: ...ire heating during its use to avoid high heating storing up in case of rapid sealings sequence Than the set time about the a case is suitable only for the first and or second sealing a first sealing o...

Страница 8: ...tter knob n 4 pict 2 to one the two edges to allow the spool in feed Place the spool on the rolls n 2 pict 2 and introduce the spool edge through the slit as shown in the pict 5 till it will exit betw...

Страница 9: ...h could be damaged for normal use for too long sealing time or for the casual introduction of any tools between the bars For the replacement proceed as follows a set the pivoted plain n 3 pict 6 on th...

Страница 10: ...tools or any other solid objects between the bars For the replacement follow the upper instructions till the point c removing the protective cloth too Then a unscrew the two screws n 28 pict 7 b remov...

Страница 11: ...6 pict 8 or n 7 pict 2 could consume or damage For the replacement proceed as follows a extract the cutter knob n 4 pict 2 in vertical direction b remove the pivoted plain cover n 3 pict 2 after unscr...

Страница 12: ...knob n 4 pict 2 in vertical direction b remove the pivoted plain cover n 3 pict 2 after unscrewing the two screws n 5 pict 2 c Move the cursor n 34 pict 9 totally on the left and remove it from its p...

Страница 13: ...does not work a Set the main switch n 2 pict 1 in position OFF 0 b extract the fuses from the fuse box see below and replace them with other of the same kind and with the same value pict 10 7 pivoted...

Страница 14: ...3 electric supply socket 51 electronic timer board 4 line fuses box 52 EMQ ant jamming filter 12 lower sealing bar 53 command panel board 48 opening pivoted plain spring 54 electromagnet resistance st...

Страница 15: ...agnet CP command panel MTR heating starting micro switch EL electromagnet R strap resistance F ant jamming filter SC electronic safety board FC9 flat cable 9 pins TC electronic timer board FL fuses 4...

Страница 16: ...mmand panel MTR heating starting micro switch EL electromagnet R strap resistance F ant jamming filter SC electronic safety board FC9 flat cable 9 pins TC electronic timer board FL fuses 6 3 AF TR tra...

Страница 17: ...screw 06032 29 pict 7 4 compensation spring 20011 16 pict 8 1 complete upper mobile bar 20005 32 pict 8 3 pressure rubber 48002 35 pict 9 1 blade XI LIST OF THE SPARE PARTS FOR THE EXTRAORDINARY MAINT...

Страница 18: ...pted The closing bar control micro switch is interrupted Set the hand wheel as shown on page 5 Put in contact with the manufacturer Replace the resistance after checking electrical circuit as shown on...

Страница 19: ...parts not manufactured by GANDUS the warranty is conditioned by the one provided by the supplier For the duration of the warranty too if the heat sealer is subject to any intervention by our personne...

Отзывы: