Important Safety Information

Important Safety Information

Notes: 1) Save this Important Safety Information section 

in a readily accessible location.

2) Although Diesel Exhaust Fluid (DEF) is 

non-flammable, Diesel is flammable. Therefore, 
for DEF cabinets that are attached to Diesel 
dispensers, follow all the notes in this section 
that pertain to flammable fuels.

This section introduces the hazards and safety precautions 
associated with installing, inspecting, maintaining, or servicing 
this product. Before performing any task on this product, read 
this safety information and the applicable sections in this 
manual, where additional hazards and safety precautions for 
your task will be found. Fire, explosion, electrical shock, or 
pressure release could occur and cause death or serious injury, 
if these safe service procedures are not followed. 

Preliminary Precautions

You are working in a potentially dangerous environment of 
flammable fuels, vapors, and high voltage or pressures. Only 
trained or authorized individuals knowledgeable in the related 
procedures should install, inspect, maintain, or service this 
equipment

.

Emergency Total Electrical Shut-Off

The first and most important information you must know is how 
to stop all fuel flow to the pump/dispenser and island. Locate 
the switch or circuit breakers that shut off all power to all fueling 
equipment, dispensing devices, and Submerged Turbine 
Pumps (STPs). 
 

Total Electrical Shut-Off Before Access

Any procedure that requires access to electrical components or 
the electronics of the dispenser requires total electrical shut off 
of that unit. Understand the function and location of this switch 
or circuit breaker before inspecting, installing, maintaining, or 
servicing Gilbarco equipment.

Evacuating, Barricading, and Shutting Off

Any procedure that requires access to the pump/dispenser or 
STPs requires the following actions:

• An evacuation of all unauthorized persons and vehicles 

from the work area 

• Use of safety tape, cones, or barricades at the affected 

unit(s)

• A total electrical shut-off of the affected unit(s)

Read the Manual

Read, understand, and follow this manual and any other labels 
or related materials supplied with this equipment. If you do not 
understand a procedure, call the Gilbarco Support Center at 

1-800-800-7498. It is imperative to your safety and the safety 

of others to understand the procedures before beginning work.

Follow the Regulations

Applicable information is available in National Fire Protection 
Association (NFPA) 30A; 

Code for Motor Fuel Dispensing 

Facilities and Repair Garages

, NFPA 70; 

National Electrical 

Code (NEC)

, Occupational Safety and Health Administration 

(OSHA) regulations and federal, state, and local codes. All 
these regulations must be followed. Failure to install, inspect, 
maintain, or service this equipment in accordance with these 
codes, regulations, and standards may lead to legal citations 
with penalties or affect the safe use and operation of the 
equipment.

Replacement Parts

Use only genuine Gilbarco replacement parts and retrofit kits 
on your pump/dispenser. Using parts other than genuine 
Gilbarco replacement parts could create a safety hazard and 
violate local regulations.

Safety Symbols and Warning Words

This section provides important information about warning 
symbols and boxes.

Alert Symbol 

 This safety alert symbol is used in this manual and on 

warning labels to alert you to a precaution which must be 
followed to prevent potential personal safety hazards. Obey 
safety directives that follow this symbol to avoid possible injury 
or death.

Signal Words

These signal words used in this manual and on warning labels 
tell you the seriousness of particular safety hazards. The 
precautions below must be followed to prevent death, injury, or 
damage to the equipment:

DANGER

:

 

Alerts you to a hazard or unsafe practice 

which will result in death or serious injury.

WARNING

: Alerts you to a hazard or unsafe practice 

that could result in death or serious injury. 

CAUTION

 with Alert symbol: Designates a hazard or 

unsafe practice which may result in minor injury.

CAUTION

 without Alert symbol: Designates a hazard or 

unsafe practice which may result in property or 
equipment damage.

Working With Fuels and Electrical Energy

Prevent Explosions and Fires

Fuels and their vapors will explode or burn, if ignited. Spilled or 
leaking fuels cause vapors. Even filling customer tanks will 
cause potentially dangerous vapors in the vicinity of the 
dispenser or island.

DEF is non-flammable. Therefore, explosion and fire safety 
warnings do not apply to DEF lines.

The EMERGENCY STOP, ALL STOP, and 
PUMP STOP buttons at the cashier

s station 

WILL NOT shut off electrical power to the 

pump/dispenser. This means that even if you 
activate these stops, fuel may continue to flow 
uncontrolled. 
You must use the TOTAL ELECTRICAL 

SHUT-OFF in the case of an emergency and not 
the console

s ALL STOP and PUMP STOP or 

similar keys.

!

WARNING

!

!

!

!

Содержание Passport MDE-3839

Страница 1: ...s Commission FCC Warning 5 Hazardous Zones 5 UL Approvals System Requirements and Component Specifications 5 Before Installing Passport System 6 Parts List 9 Appendix Procedure to Change POSIFLEX Moni...

Страница 2: ...Administration POS Point of Sale RAS Remote Access Service RFID Radio Frequency Identification STP Submersible Turbine Pump SZR Secure Zone Router UL Underwriters Laboratories UPS Uninterruptible Pow...

Страница 3: ...safety of others to understand the procedures before beginning work Follow the Regulations Applicable information is available in National Fire Protection Association NFPA 30A Code for Motor Fuel Dis...

Страница 4: ...victim for example baby teenager middle age elderly Whether or not victim has received first aid for example stopped bleeding by pressure and so on Whether or not a victim has vomited for example if...

Страница 5: ...manufacturer could void the user s authority to operate this equipment The long term characteristics or the possible physiological effects of radio frequency electromagnetic fields have not been inves...

Страница 6: ...0 Altitude Sea level to 10 000 Thermal printers must use Gilbarco specified paper Operating Environment Aspect Limits Temperature 22 to 131 F 30 to 55 C Relative Humidity 5 to 95 non condensing Altitu...

Страница 7: ...re a Warranty Return Materials Authorization Form for more information refer to MDE 2149 Warranty Return Materials Authorization to ship with the device Note Gilbarco recommends that returned equipmen...

Страница 8: ...e cables between the equipment Do not route data cables in the same conduit as AC wiring or near sources of interference such as fluorescent lights compressor wiring and so on Do not coil bend or tie...

Страница 9: ...cure Zone Router SZR 0 N A 1 S 1 S UPS PA03310004 UPS 6 USB Cable and 6 Power Cord included for V4 and later 1 O 1 O 1 O EDH2 PA0419000X Dispenser Hub Power Supply and two 6 LAN Patch Cords included 0...

Страница 10: ...nitec bag of 5 only packed in Combined and Standalone Install Kits 0 N A 1 Ref N A 1 Ref N A Q13180 16BS Gender Mender Code A Wash 3 bag of 5 only packed in Combined and Standalone Install Kits 0 N A...

Страница 11: ...he Cable Harness Assembly 1 O 1 O 0 N A Customer Display PA03270103A PA03270400 Customer Display 4 Serial Cable and DC Cable 8 to 115 VAC Wall Power Supply included 1 S 1 S 0 N A Touchscreen Monitor w...

Страница 12: ...ional O Qty Standard S Optional O Notes 1 USB to RS 232 Converter choose 16 port converter if Tank Monitor is required for the order 2 CAT5 cable must be ordered separately XX 10 25 and 50 maximum rec...

Страница 13: ...0 N A 1 O SZR PA0424000X SZR with 6 inch DC Power Supply Cord 0 N A 1 O QWERTY Keyboard and Mouse Q13181 09 USB QWERTY Keyboard and Mouse 1 S 1 S UPS PA03310004 UPS 6 USB Cable and 6 Power Cord includ...

Страница 14: ...0 Customer Display Serial Cable 4 and DC Cable 8 to 115 VAC Wall Power Supply included 1 S 1 S PIN Pad with Card Reader PA0411000XXX PA0412000XXX PA0420000XXXX PIN Pad with Card Reader 9 RS 232 Cables...

Страница 15: ...CWS MWS Standalone MWS Q11121 07 Power Strips 1 1 1 Q11121 10 Power Strips 0 1 0 Q13180 20B Gender Mender at USB Converter Bag of 5 Server Environmental Management Console EMC Price Sign Car Wash GSM...

Страница 16: ...ange POSIFLEX Monitor LM 3110E Resolution Setting To change the resolution setting proceed as follows 1 Connect the power cable and power up the monitor From the Control Panel navigate to the Display...

Страница 17: ...the Advanced tab A new window with multiple tabs open see Figure 3 Figure 3 Selecting Advanced Tab 4 Navigate to the Intel HD Graphics Control Panel tab Set values as shown in figure and click Apply s...

Страница 18: ...nd brands are the property of their respective owners and are for identification purposes only Use of these names logos and brands does not imply endorsement 2020 Gilbarco Inc 7300 West Friendly Avenu...

Отзывы: