Capricorn PLUS Installation Note 

 

 

DCP0000273(B) 

This installation note is applicable for SkyEdge II-c Capricorn PLUS CPE. The Capricorn PLUS CPE hardware 

includes two parts to achieve high performance capabilities: the Modem (Capricorn Pro/MEC-based) and the Compute 

Node that supports most of the Capricorn Pro/MEC data processing features.  

 

To install the SkyEdge II-c Capricorn MEC CPE, the installer must:  

 

Be trained in how to install the SkyEdge II-c Capricorn PLUS CPE 

 

Be familiar with the SkyEdge II-c Capricorn PLUS VSAT Installation Manual DC-54TS005(A) 

 

Have the CPE configuration parameters available

 

 

The SkyEdge II-c Capricorn PLUS CPE is meant to be installed in a 19-inch rack. The CPE should be inserted in the 

rack and secured using rack-mount ears.  

The CPE can be installed with either front or rear panel facing forward. By default, the CPE is supplied with rack-

mount front ears secured to the front panel. The installation kit includes an additional pair of rack-mount back ears for 

securing to the CPE rear panel to install the CPE with the rear panel facing forward. 

 

Unpacking Guidelines 

1.

 

Unpack the Capricorn PLUS CPE unit and its accessories. 

2.

 

Compare with the supplied BOM and verify that all the items are supplied in good condition.

 

 

 

VSAT AC and DC power supplies are provided by Gilat. If the power to the VSAT is not 

through an AC or DC adaptor (e.g., batteries, solar panels, rectifier ETC), the power solution 

must be approved by the Gilat Technical Support.

 

 

 

C

AUTION

 

  T

HE 

CPE

 MUST BE GROUNDED PRIOR TO INSTALLATION BY ATTACHING ONE END OF THE GROUNDING CABLE 

TO THE GROUNDING  STUD ON THE REAR OF THE 

CPE,

 AND THE OTHER END TO THE SITE MAIN GROUND 

CONNECTION

.

 

18AWG

 GROUNDING CABLE SHOULD BE USED

  T

HE 

CPE

 MUST BE CONFIGURED PRIOR TO ATTACHING THE 

RF

 CABLES

 

T

HE POWER CABLE MUST BE DISCONNECTED FROM THE 

CPE

 PRIOR TO CONNECTING THE 

RF

 CABLES

.

 

 

 

 

General Precautions 

 

Do not block the ventilation openings of the CPE or place any object on top of the CPE.

 

 

Do not place the CPE in a location that would deviate from typical ambient environmental conditions 

of temperature, humidity, and moisture.

 

 

  

 

Warning 

B

EFORE INSTALLING THE UNIT

,

 VERIFY THAT THE ANTENNA IS GROUNDED SO AS TO PROVIDE PROTECTION 

AGAINST VOLTAGE SURGES AND STATIC CHARGES

S

ECTION 

810

 OF THE 

US

 

N

ATIONAL 

E

LECTRICAL 

C

ODE

,

 

ANSI/NFPA

 

70,

 AND 

S

ECTION 

54

 OF THE 

C

ANADIAN 

E

LECTRICAL 

C

ODE PROVIDE INFORMATION WITH REGARD TO PROPER GROUNDING OF THE MAST AND 

SUPPORTING STRUCTURE

,

 GROUNDING OF THE LEAD

-

IN WIRE TO AN ANTENNA DISCHARGE UNIT

,

 SIZE OF 

GROUNDING CONDUCTORS

,

 LOCATION OF ANTENNA DISCHARGE UNIT

,

 CONNECTION TO GROUNDING ELECTRODES 

AND REQUIREMENTS FOR THE GROUNDING ELECTRODE

.

 

 

Setting Output Voltage 

1.

 

Select the power according to the BUC you intend to use before connecting the power to the VSAT. 

2.

 

The VSAT's default output voltage setting is 24V. The output voltage test must be performed (step 4). 

3.

 

Using a flat screwdriver, set the right-side output voltage to 48V, and the left side output voltage to 24V. 

4.

 

Turn on the VSAT and verify that the LED that signals the output voltage is the selected 24V or 48V 

5.

 

Turn off the VSAT and start the installation. 

Содержание SkyEdge II-c Capricorn PLUS

Страница 1: ...ical Support CAUTION THE CPE MUST BE GROUNDED PRIOR TO INSTALLATION BY ATTACHING ONE END OF THE GROUNDING CABLE TO THE GROUNDING STUD ON THE REAR OF THE CPE AND THE OTHER END TO THE SITE MAIN GROUND CONNECTION 18AWG GROUNDING CABLE SHOULD BE USED THE CPE MUST BE CONFIGURED PRIOR TO ATTACHING THE RF CABLES THE POWER CABLE MUST BE DISCONNECTED FROM THE CPE PRIOR TO CONNECTING THE RF CABLES General P...

Страница 2: ...the LAN ports are operational Connecting Grounding Cable Connect the grounding cable GND from the CPE to the approved site Connecting Power Cable Warning TO REDUCE THE RISK OF ELECTRIC SHOCK DISCONNECT ALL POWER CORDS BEFORE SERVICING THE UNIT The Capricorn PLUS CPE is powered with a 48VDC external power source The CPE power connection uses the optionally supplied Gilat power cables CB000912 that ...

Страница 3: ... 30dB Symbol Rate 256Ksps Duration 60 second 6 Click Activate The specified frequencies represent the worst case scenario requiring the modem to use lower attenuator values for driving the BUC to maximum output power 7 Measure the BUC output power and then from the webpage click Deactivate to cease transmission of the test signal Ideally the BUC should be powered at least 5 10 minutes prior to tak...

Страница 4: ...TX Out port of the modem and connect the RF cable P N CB052230 Cable RF Type RF Type RG6 LF20cm to the other port of the attenuator If the attenuator has an F Type male connector connect the attenuator directly to the modem If the attenuator has two F Type female connectors use the short cable provided with the modem to connect the attenuator to the modem CAUTION IT IS HIGHLY RECOMMENDED TO POWER ...