7
1
System out line
・
“GSK” is the torque control type nut runner system what has the function necessary to tightening of the screw
and locating.
・
This system has the name specified as GSK and it can be divided into the controller section, IF unit
section(Interface) and AC nut runer section.
Controller section
・
Tightening accuracy :
3σ±2
%
・
GSK series improved a conventional GSS series, that was realized downsized, model integration and
processing speed Improvement by the capacity rise of CPU and a memory
・
Tightening program sets the rotation number and torque control, facilitating the wide variety of tightening
patterns.
・
High-speed and highly accurate tightening control is provided by combinig the position control and the torque
control.
・
Self diagnosis function displays the program number/operating condition/alarm information on the front LED
display.
・
Three setup methods are provided to setup the tightening program: the input method from the setup personal
computer, exclusive display and that from the controller front panel.
・
It is easy even for beginners to set up and input because the automatic setup and input function has been
installed.
IF unit section
・
IF unit is the communication device to communicate with the external unit such as the sequencer/display/setup
personal computer/printer or other equipment.
・
GSK system allows you to check the information related to the tightening control such the setting
data/tightening results by connecting a personal computer to the IF unit.
・
It is possible to check the information by connecting to a printer without inputting the data such as the
setting/tightening results into a personal computer.
・
Communication setting is applicable to both specifications of PIO and SIO.
・
One IF unit is always required by set of controller.(2 units for 31 axes or more).
Содержание GSK Series
Страница 1: ...Instruction Manual GSK GSKW Controller November 2017 GIKEN INDUSTRIAL CO LTD The 3rd edition...
Страница 16: ...15 Size Interface dimensions Standard type GSK IF...
Страница 17: ...16 Controller dimensions Standard type GSK 4 GSKW 4...
Страница 18: ...17 Controller dimensions Standard type GSK 5 7...
Страница 19: ...18 Controller dimensions T type GSK T5 T7...
Страница 20: ...19 Controller dimensions Standard type GSKW 5...
Страница 21: ...20 Controller dimensions T type GSKW T5...
Страница 22: ...21 Dimensions display Model GSK D1 Panel cut out dimensions Back Side Front Under...
Страница 23: ...22 Wire connection Wiring reference diagram M net ver GSKW Controller system wiring reference diagram...
Страница 24: ...23 M net ver GSK Controller system wiring reference diagram...
Страница 28: ...27 External connection diagram I F unit Connected equipment standard and T type...
Страница 50: ...49 Setting...
Страница 58: ...57 Reverse tightening reference waveform...
Страница 62: ...61...
Страница 63: ...62 Gradient calculation method...