background image

The information in this document is subject to change without notice

Copyright   1991 ~ 2012 KMW, INC.  All Rights Reserved

©

3

Document Revision V0.61 2013.01.15

Pages

R

Street Light 

(HR) 

Installation & Operation User Guide

Product Over

view

Product F

eatures

1) Scope Overview

This manual describes how to compose, install, and operate LED streetlamps.

2) LED Streetlamp Apparatus (LED Streetlight)

A streetlamp is a lamp that is installed on the side of least four-lane roads to improve traffic safety of vehi-
cles and civilians as well as traffic efficiency.

3) Usage
    

This is a traffic safety facility not only for expressways, streets, parking lots, and industrial facilities, but also  

     for the safety on motorways or sidewalks. It is roughly divided into road lamps, sidewalk lamps, overbridge   
     lamps, and high-mast lightings. The shape varies with the road feature and the beauty concept of your city 
     to give you a lot of choices.
     The HR product lineup is 85W, 110W, 150W and all of them are proud of their high lamp efficiency over 
     100 lm/W. The lamp efficiencies are 8,500 lm, 11,000 lm, and 15,000 lm, respectively.
     The light distribution type is diversified. It supports Type II-S, Type II-M, Type III-S, Type-III-M to enable
     streetlamp installation in all environments.

1) Vertically Arranged LED Module Method

HR adopted vertically arranged LED moduled unlike existing streetlamps. The vertically arranged LED mod-
ules can help to minimize the heat generating from the LED and further guarantee long life of the device  in 
the long run.

2) An Electronic Auto Switch Is Attached

On top of a product is installed an electronic Auto Switch. When the intensity of illumination reaches a certain 
level, the lamp will be automatically turned off first and then it will be automatically turned off while it is not 
securing an illumination with sufficient intensity. In other words, it is a very convenient function to automati-
cally turn on or off the lamp without operating the switch whenever necessary.

3) Converter (SMPS) Exchange without Tools

HR adopted the Locking Lactch type to the locking device in the SMPS enclosure part to open or close the 
enclosure without any tool when you are exchanging the SMPS. In addition, the internal SMPS is fixed not  
by bolts but not sockets for more comfortable maintenance.

4) Silver Nanoreflecting Plate

A nanoreflecting plate is expected to make effect on raising the intensity of illumination, i.e., improving the brightness 
when it is used for illumination. Although we install a lamp with lower wattage than those of the other companies, we 
can realize the intensity of illumination equivalent to or higher than them, eventually with more outstanding electricity-
saving effect.

Содержание HR 110W

Страница 1: ...HR R 85W 110W 150W Product Installation Operation User Guide http www kmwgigatera com Installation Operation User Guide Roadway Lighting LED...

Страница 2: ...ires Make sure the grounding is performed under Electricity Standards Using it for any voltage other than specified can cause failure or fire Do not use it in moist environment Be mindful of proper ve...

Страница 3: ...nts 1 Vertically Arranged LED Module Method HR adopted vertically arranged LED moduled unlike existing streetlamps The vertically arranged LED mod ules can help to minimize the heat generating from th...

Страница 4: ...the assumption an Electronic Auto Switch is installed to each product A product with an Electronic Auto Switch may look different from what it looks like in the brochure Although the other parts than...

Страница 5: ...1 2012 KMW INC All Rights Reserved 5 Document Revision V0 61 2013 01 15 Pages R Street Light HR Installation Operation User Guide HR Converter Detail Description No Item Purpose HR LED Streetlamp Conv...

Страница 6: ...Pages R Street Light HR Installation Operation User Guide Illumination Sensor Intensity Detail Description No Item Purpose HR LED Streetlamp Converter Lamp and Brightness Sensor Power Supply Device SM...

Страница 7: ...Operation User Guide HR DCM Converter Package 3 Built In DCM Type Dimming Control Once installed the DCM module will be synchronized with the LCS system for illumination control to enable the dimming...

Страница 8: ...ail Description No Item Purpose HR LED Streetlamp Converter Lamp and Brightness Sensor Power Supply Device SMPS DCM Data Control Module LCS Controllwe is not included Illumination Sensor In tensity Su...

Страница 9: ...ke sure the cutter blade doesn t enter deep enough to scratch the product surface Also be careful not to hurt yourself Once the box is open you will see a package fully covering the product Open the t...

Страница 10: ...he following figure If you don t use the Electronic Auto Switch skip the above step and jump to Step 10 Swing the receptacle horizontally and set it as close as to the north on the basis of the arrow...

Страница 11: ...tion against the direction nature may damage the lamp connection part The brightness sensor is optional and it may look different from what it looks like in the figure if it is bought by the user Alig...

Страница 12: ...w er cable wiring To begin with use your thumb to push the latch lock er upward and pull the lower part like the following figure When you zoom in the image the part that was hid den for easier descri...

Страница 13: ...tion User Guide Open the SMPS part and hang it on the hook before you start wiring InserttheACpowercablebehindthearmlikethefol lowing figure HR Model basically does not supply the AC power cable If ne...

Страница 14: ...bond them together Attach the lamp to the light pole like the fol lowing figure Once the lamp is installed use fixing bolts to fix it to the light pole When you remove the cap on top of the lamp as il...

Страница 15: ...t the time of power supply Use the twister to connect the two cores of the black cable N with each other like the following figure Each cable comes from the core after it is connected to the AC power...

Страница 16: ...o control the lighting sur face by 5 in vertical direction Please remember the default of the product is set to 0 when it is shipped out from the factory Do not disassemble the fixing bolt for angle s...

Страница 17: ...ng aligning its first and third bolt holes with the corresponding light pole holes and bolt parts together for fixing like the following figure Put the bolts through the points where both holes are al...

Страница 18: ...ing RF LED Provider 1521 E Orangethorpe Ave Ste A Fullerton CA 92831 U S A 183 6 Yeongcheon ro Dongtan myeon Hwaseong si Gyeonggi do Korea 1 714 515 1100 sales kmwgigatera com 82 31 370 8720 chriskim...