34
V
e
rsio
n 2,
06
.0
8.
201
0 / M
o
d
u
leV
e
rs
io
n 1.
0
Taking measurements
Gigaset N870 IP PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / measure.fm / 8/24/18
Example of a measurement log for measuring the synchronisation overlap
The result of the measurement is that the signal strength is sufficient for synchronisation
everywhere. Base station E only receives base station D with sufficient quality.
Here, a sensible synchronisation hierarchy would be:
Measur-
ing
point
Base station A
Base station B
Base station C
Base station D
Base station E
A
-52 dBm/100%
-40 dBm/100%
-58 dBm/100%
----
B
-50 dBm/100%
-48 dBm/100%
----
-70 dBm/92%
C
-42 dBm/100%
-46 dBm/100%
-50 dBm/100%
----
D
–60 dBm/100%
-----
-48 dBm/100%
-64 dBm/100%
E
----
-68 dBm/94%
----
-62 dBm/100%
Sync level 1
Base station C
Sync level 2
Base stations A, B and D
Sync level 3
Base station E