CAUTION

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the 

electrical installation of the building.

When Installing the Unit
•  Never plug in nor remove the power supply plug with 

wet hands, as doing so may cause electric shock.

•  When unplugging the power supply cord, be sure to 

grasp the power supply plug; never pull on the cord 

itself. Operating the unit with a damaged power sup-

ply cord may cause a fire or electric shock.

•  When moving the unit, be sure to remove its power 

supply cord from the wall outlet. Moving the unit with 

the power cord connected to the outlet may cause 

damage to the power cord, resulting in fire or elec-

tric shock. When removing the power cord, be sure 

to hold its plug to pull.

•  Do not block the ventilation slots in the unit’s cover. 

Doing so may cause heat to build up inside the unit 

and result in fire.

•  Avoid installing the unit in humid or dusty locations, 

in locations exposed to the direct sunlight, near the 

heaters, or in locations generating sooty smoke or 

steam as doing otherwise may result in fire or elec-

tric shock.

When the Unit is in Use
•  Do not place heavy objects on the unit as this may 

cause it to fall or break which may result in personal 

injury and/or property damage. In addition, the object 

itself may fall off and cause injury and/or damage.

•  Make sure that the volume control is set to mi-

nimum position before power is switched on. 

Loud noise produced at high volume when power is 

switched on can impair hearing.

•  Do not operate the unit for an extended period of 

time with the sound distorting. This is an indication 

of a malfunction, which in turn can cause heat to ge-

nerate and result in a fire.

•  Contact your dealer as to the cleaning. If dust is al-

lowed to accumulate in the unit over a long period of 

time, a fire or damage to the unit may result.

•  If dust accumulates on the power supply plug or in 

the wall AC outlet, a fire may result. Clean it perio-

dically. In addition, insert the plug in the wall outlet 

securely.

•  Switch off the power, and unplug the power supply 

plug from the AC outlet for safety purposes when 

cleaning or leaving the unit unused for 10 days or 

more. Doing otherwise may cause a fire or electric 

shock.

Содержание GGM IPAW215D

Страница 1: ...DRESS GGM IPAW215D USER MANUAL www gigamedia net Please follow the instructions in this manual to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference ...

Страница 2: ...cury Pb Lead To facilitate the treatment and recycling of used batteries you can return them to your dealer deposit them in a collection bin provided for this purpose or return them to your municipal waste which is obliged to recover them WEEE regulation This product is covered by the WEEE II Directive Directive 2012 19 EU It should not be thrown in the trash or dumped Substances in the product ma...

Страница 3: ...cluding the unit itself on the power cord as doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is ap plied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth ter minal to avoid electric shock Never ground to a gas pipe as a catastrophic di...

Страница 4: ... near the heaters or in locations generating sooty smoke or steam as doing otherwise may result in fire or elec tric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to...

Страница 5: ... time for audio acquisition playback and pagingl is less than 30mS 05 Built in play acquisition ondemand module to achieve real time play the audio from media library on demand 06 Built in 2 30W digital amplifier with less heat but higher efficiency and CD level sound quality 07 One MIC input one line input one line output suitable for local public address broadcast 08 Priority functions 1 Network...

Страница 6: ...r remote control receiver port 02 Display Screen display all the current operating functions 4 2 REMOTE CONTROL 01 Additional button 02 PREV PREV button 03 Hang up button 04 Number button button 05 Enter button 06 Next Move next button 07 Cancel pause play button 08 Volume down button 09 Volume up button 10 Menu button ...

Страница 7: ...switch signal and short circuit signal is controlled by the green light mode of IP software 04 LAN and RJ45 interface to connect PC host Ethernet switch network 05 MIC input port 06 MIC and AUX Volume adjustment knob 07 AUX input to connect CD type audio equipment 08 LINE OUT external connection to local public address 09 Speaker input port 10 Speaker output port 11 Grounding column LAN IN MIC IN ...

Страница 8: ...en you will have to press the button Inquire Figure 1 to display the equipments found by iptool Figure 2 You will now have to change the IP address of your equipment to match the IP addresses of your network You need to fill every field below New terminal Figure 3 Once all the fields are filled press the button Write to apply the configuration and check with the button Ping to see if it is reachab...

Страница 9: ... shows as following picture 2 On standby mode press MENU enter into the menu the screen shows as following picture 3 In the menu interface press the number buttons on the panel of 1 to enter to view the IP address of the machine interface as belows 4 In the menu interface click on the panel keypad 2 you can view the current state of play as belows 5 In the menu interface click on the panel keypad ...

Страница 10: ...all you can achieve the call to other devices via APPEND button on the machine panel to increase the need to call apparatus for encoding use the volume up down keys to adjust the current size of the volume as belows 8 If the call encoding the current input is incorrect through REMOVE button on the machine panel to withdraw the call After the call is finished press the HANG UP button to hang up the...

Страница 11: ... LAN IN MIC IN VOL 0 10 AUX IN SPK OUT1 LINE OUT red green Short circuit output AC power supply MIC input Speaker CD MP3 player ON OFF POWER CLIP TEMP PROT SIGNAL VOLUME 5 0 1 2 3 4 6 7 8 9 10 24V Power adapter DC24V 2A GND Network switch Speaker External connect to public address equipment ...

Страница 12: ... GGM IPAW215D 12 7 BLOCK DIAGRAM Power Swi tch POWER A C IN POWER M CU 100M 3 4 i nches L M 6063DCW GPI O1 I R L I NE OUT A M P TPA 3130D2DA P A UX I NPUT 350mV M I C 5mV I NPUT A M P OUT 2 15W 8R L I NE OUT Short ci rcui t output red green ...

Страница 13: ... matrix display screen Operating mode Infrared remote control Remote control distance 10 m straight line barrier free External speaker impedance and Rated Power 8 Ω 2x15 W THD THD 1 Frequency response 80 Hz 16 kHz 3 dB 0 dB SNR 65 dB AUX IN input sensitivity 350 mV connector of industrial standard MIC input sensitivity 5 mV Operation temperature 5 C 40 C Operation humidity 20 80 relative humidity ...

Страница 14: ...www gigamedia net GIGAMEDIA User manual GGM IPAW215D 14 9 INSTALLATION METHOD Anchor screw holes Anchor screw holes ...

Отзывы: