background image

- 66 -

BIOS Setup

5-6  Save & Exit Menu

The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit 
options then press <Enter>

.

 

Parameter

Description

Save Options

Save Changes and Reset

Saves changes made and closes the BIOS setup. 
Options available: Yes, No.

Discard Changes and Reset

Discards changes made and exits the BIOS setup.
Options available: Yes, No.

Restore Defaults

Loads the default settings for all BIOS setup parameters. Setup Defaults 
are quite demanding in terms of resources consumption. If you are using 
low-speed memory chips or other kinds of low-performance components 
and you choose to load these settings, the system might not function 
properly.
Options available: Yes, No.

Boot Override

Press [Enter] to configure the device as the boot-up drive.

Содержание W332-Z00

Страница 1: ...W332 Z00 AMD Ryzen Tower Entry Workstation User Manual Rev 1 0 ...

Страница 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Страница 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Страница 4: ...e power cord where it can be walked on or pinched by items placed against it Pay particular attention to the plug electrical outlet and the point where the cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION Do not operate the system for long periods with the access pan...

Страница 5: ...charge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully They...

Страница 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Страница 7: ...t back to your local or regional waste collection administration for recycling Restriction of Hazardous Substances RoHS Directive Statement GIGABYTE products have not intended to add and safe from hazardous substances Cd Pb Hg Cr 6 PBDE and PBB The parts and components have been carefully selected to meet RoHS requirement More over we at GIGABYTE are continuing our efforts to develop products that...

Страница 8: ...0 non condensing 20 95 non condensing 伺服器相關警告與注意事項 警告 為了避免電擊危險或損壞設備請注意 不要切斷電源線的接地端子 接地端子是一個很重要的安全防護 將電源線接到有接地功能的插座 此插座需位於使用者容易使用的範圍 電源線的配線要避免被踩到 被絆到或被過度彎折 重壓 警告 本設備關機後內部仍存在電源 須拔掉電源線才能完全切掉設備內部的電源 更換零件前請確定電源已經完全切斷 電源線 電話線 網路線可能帶電 維修前除了移除電源線外也請移除所有連接線 避 免電擊傷害或是設備損壞 維修非支援熱插拔的零件時須將伺服器從機櫃取下才能維修 警告 避免人員燙傷 觸摸磁碟機或是內部零件前請確保該零件已經冷卻 警告 伺服器中有高速風扇 維修時請遠離風扇避免受傷 警告 本設備不能用在有兒童出現的區域 ...

Страница 9: ... Ǻӵ ඤᒱᇤႝԣ ౢғᛈࣆ ፎа ӕ ӕࠠႝԣ ඤ Ҕ 注意 伺服器開機時不要長時間移除蓋子 長時間移除蓋子會造成散熱功能失效造成損壞 注意 靜電會損害電子產品 建議您在符合靜電防護的工作環境操作伺服器 如果無法確定 環境的靜電防護 請穿上靜電手環並且將手環接到有接地的金屬表面如機櫃或機殼 拿取電路板時僅觸碰板子的邊緣 不要觸碰連接器 板子從防靜電包裝取出後只能放 置在無靜電的桌面 零件面朝上 如果可以 請使用防靜電泡棉 避免使用靜電袋 避免 電路板與任何表面摩擦產生靜電 ...

Страница 10: ...俪 嵬 ZW 嵬 ZW ᾩ 昷䔏䉐峑Ḳ䙥 㮻 憶嵬 䙥 㮻 憶 㹽 1RWH ƝĄ FHHGLQJ ZW ą DQG ĄH FHHGLQJ ZW ą LQGLFDWH WKDW WKH SHUFHQWDJH FRQWHQW RI WKH UHVWULFWHG VXEVWDQFH H FHHGV WKH UHIHUHQFH SHUFHQWDJH YDOXH RI SUHVHQFH FRQGLWLRQ 俪 ĉ ᾩ 婙柬昷䔏䉐峑Ḳ䙥 㮻 憶㜑嵬 䙥 㮻 憶 㹽 1RWH ƝĄĉą LQGLFDWHV WKDW WKH SHUFHQWDJH FRQWHQW RI WKH UHVWULFWHG VXEVWDQFH GRHV QRW H FHHG WKH SHUFHQWDJH RI UHIHUHQFH YDOXH RI SUHVHQFH 俪 Ɛ ᾩ 婙柬昷䔏䉐峑䂡 晋柬䛕 1RWH Ɲ7KH Ą ą ...

Страница 11: ... 3 2 Installing the Memory 25 3 4 Installing the PCI Expansion Card 26 3 5 Installing the Hard Disk Drive 27 3 6 Installing and Removing the M 2 SSD Module 28 3 7 Installing and Removing the M 2 WiFi Module 28 3 8 Peripheral Devices Connection 29 Chapter 4 Motherboard Components 30 4 1 Motherboard Components 30 4 2 Jumper Setting 32 Chapter 5 BIOS Setup 33 5 1 The Main Menu 35 5 2 Advanced Menu 37...

Страница 12: ...on 55 5 2 14 Offboard SATA Controller Configuration 56 5 2 15 SATA Configuration 57 5 2 16 Realtek PCIe GBE Family Controller 58 5 3 Chipset Setup Menu 59 5 3 1 AMD PSP KVM Configuration 61 5 4 Security Menu 62 5 4 1 Secure Boot 63 5 5 Boot Menu 65 5 6 Save Exit Menu 66 5 7 BIOS POST Beep code AMI standard 67 5 7 1 PEI Beep Codes 67 5 7 2 DXE Beep Codes 67 ...

Страница 13: ... dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loca...

Страница 14: ...for 1DPC up to 3600MHz for 2DPC LAN 2 x LAN ports Realtek 2 5GbE LAN RTL8125 Realtek GbE DASH LAN RTL8111EP Video 1 x DP port supporting maximum resolution of 4096x2160 60Hz Support for DP 1 2 version 1 x HDMI port supporting maximum resolution of 4096x2160 60Hz Support for HDMI 2 1 version HDCP 2 3 HDR Audio Realtek ALC897 audio codec High Definition audio 2 4 5 1 7 1 channel 3 ports Audio Jack L...

Страница 15: ...6Gb s ports 1 x CPU fan header 3 x System fan headers 1 x Serial header COM 1 x Front panel header 1 x Front Audio header 1 x Front USB3 2 Gen1 header 1 x M 2 slot PCIe gen5 x4 M key support NGFF 2280 1 x M 2 slot PCIe gen4 x4 M key support NGFF 2280 1 x M 2 slot for Wi Fi BT module E key support NGFF 2230 Front I O 2 x USB3 2 Gen1 ports 1 x Line out port 1 x Mic in port 1 x Power Button 1 x Hard ...

Страница 16: ... settings on off restart hibernate or sleep View hardware firmware or BIOS versions Retrieve system health status USB device redirection Boot device selection View event logs Apply updates and security patches Text Console Redirection Software KVM Operating Properties Operating temperature 10 C to 35 C Operating humidity 8 80 non condensing Non operating temperature 40 C to 60 C Non operating humi...

Страница 17: ... 17 Hardware Installation 1 3 System Block Diagram ...

Страница 18: ...apter 2 System Appearance 2 1 Front View 2 5 6 7 1 3 4 No Description No Description 1 USB 3 2 Ports 5 Power Button 2 The function of 1394 Port is disabled 6 Hard Drives Status LED 3 Line Out Port 7 Reset Button 4 Mic In Port ...

Страница 19: ... 5 USB 3 2 Ports Type C 11 Line Out Port Green 6 USB 3 2 Ports 12 Mic In Port Pink 13 PCIe Card Bay The HDMI port is HDCP 2 3 compliant and supports Dolby TrueHD and DTS HD Master Audio formats It also supports up to 192KHz 24bit 7 1 channel LPCM audio output You can use this port to connect your HDMI supported monitor The maximum supported resolution is 4096x2160 60Hz but the actual resolutions s...

Страница 20: ... 1GbE Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or reception is occurring N A Off No data transmission or reception is occurring 1 2 1 2 ...

Страница 21: ...ou are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal system of the computer case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to d...

Страница 22: ...ve install the chassis side cover and front bezel 1 Remove the screw securing the chassis side cover 2 Slide the cover towards the rear of the system and then remove the cover in the direction indicated by the arrow 3 Remove the front bezel 4 Remove the dummy cover 5 Remove the EMI shielding 6 Reinstall the front bezel 7 Follow steps 1 2 in reverse order to re install the chassis side cover 1 1 2 ...

Страница 23: ...ace the system unit on a flat and stable surface Open the system according to the instructions WARNING Failure to properly turn off the server before you start installing components may cause serious damage Do not attempt the procedures described in the following sections unless you are a qualified service technician Follow these instructions to Install the CPU 1 Lift up the CPU socket locking lev...

Страница 24: ...uidelines before you begin to install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same capacity brand speed and chips be used Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage Memory modules have a foolproof design A memory module can be installed in only one di...

Страница 25: ...the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 Note DIMM must be populated in sequential alphabetic order starting with DIMM2 DDR4_A2 When only one DIMM is used it must be populated in memory slot DIMM2 DDR4_B2 Memory...

Страница 26: ...ed from the server prior to installing a PCIe card Failure to observe these warnings could result in personal injury or damage to equipment Follow these instructions to install the PCI Expansion card 1 Use a screw driver to push the slot cover 2 Remove the slot cover from the PCIe bracket 3 Align the PCIe card onto the slot and push in the direction of the arrow until the PCIe card sits in the PCI...

Страница 27: ... the hard disk drive connector on the backplane Follow these instructions to install 3 5 hard disk drives 1 Remove both side covers 2 Slide the first hard disk drive into the slot 3 Mount it with two screws on each side 4 Slide the second hard disk drive into the dedicated HDD tray Note Connect your GIGABYTE sales representative with any order requests 5 Screw the hard disk drive with four screws ...

Страница 28: ...module into the slot Step2 Secure it with the screw tightening as necessary to fasten the M 2 SSD module in place 1 2 Follow the steps below to install a M 2 WiFi module on your motherboard Step1 Carefully Insert the M 2 WiFi module into the slot Step2 Secure it with the screw tightening as necessary to fasten the M 2 WiFi module in place 3 7 Installing and Removing the M 2 WiFi Module ...

Страница 29: ... 29 System Hardware Installation 3 8 Peripheral Devices Connection 1 2 ...

Страница 30: ...0 Motherboard Components Chapter 4 Motherboard Components 4 1 Motherboard Components CPU DIMM_P0_A0 DIMM_P0_A1 DIMM_P0_B0 DIMM_P0_B1 3 4 5 1 2 6 7 8 11 9 10 12 14 18 19 16 13 15 17 20 21 22 23 24 25 26 27 ...

Страница 31: ...nector 2 11 2x12 Pin Main Power Connector 12 Battery Socket 13 SATA III 6Gb s Connector 0 1 14 SATA III 6Gb s Connector 2 3 15 Front Panel Header 16 Front Panel USB 3 2 Connector 2 17 M 2 Slot PCIe Gen3 x2 Support NGFF 2280 18 M 2 Slot PCIe Gen4 x4 Support NGFF 2280 19 Front Panel USB 3 2 Connector 1 20 COM1 21 PCIe x4 Slot Gen3 x4 22 PCIe x1 Slot Gen3 x1 23 PCIe x16 Slot Gen5 x16 24 M 2 Slot WiFi...

Страница 32: ...ard Components 4 2 Jumper Setting Clear CMOS CLR_CMOS1 Clear CMOS data Normal Opera on Default CPU DIMM_P0_A0 DIMM_P0_A1 DIMM_P0_B0 DIMM_P0_B1 3 4 5 1 2 6 7 8 11 9 10 12 14 18 19 16 13 15 17 20 21 22 23 24 25 26 27 ...

Страница 33: ... with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this cha...

Страница 34: ...ser password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make changes Boot This setup page provides items for configuration of the boot sequence Save Exit Save all the changes made in the BIOS Setup program to the CMOS ...

Страница 35: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Страница 36: ...C Address Note1 Displays LAN MAC address information Total Memory Note2 Displays the total memory size of the installed memory System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format Note1 The number of LAN ports listed will depend on the motherboard system model Note2 This section will display capacity and freq...

Страница 37: ...IOS Setup 5 2 Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen ...

Страница 38: ...ormation RealManage Implementation Guide version Displays the utility version RealMange Firmware Control Note Enable Disable RealMange Firmware Control Options available Enabled Disabled Default setting is Disabled DASH Support Enable Disable DASH Support Options available Enabled Disabled Default setting is Disabled Note Advanced items prompt when this item is defined ...

Страница 39: ...MBIOS Enable Disable PLDM Support for SMBios Options available Enabled Disabled Default setting is Enabled PLDM for BIOS Control and Configuration Enable Disable PLDM Support for BIOS Control Options available Enabled Disabled Default setting is Enabled PLDM for Platform Monitoring Enable Disable PLDM for Platform Monitoring Options available Enabled Disabled Default setting is Enabled Note Advanc...

Страница 40: ...IOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable Active PCR banks Displays active Platform Configuration Register PCR banks Available PCR banks Displays available PCR banks SHA 1 PCR Bank Enable Disable SHA 1 PCR bank Options available Enabled Disabled Default setti...

Страница 41: ...rchy Enable Disable storage hierarchy Options available Enabled Disabled Default setting is Enabled Endorsement Hierarchy Enable Disable endorsement hierarchy Options available Enabled Disabled Default setting is Enabled TPM2 0 UEFI Spec Version Selects the TCG2 spec version support Options available TCG_1_2 TCG_2 Default setting is TCG2 Physical Presence Spec Version Selects the physical presence...

Страница 42: ...rameter Description Alert Standard Format ASF Configuration ASF BIOS Mode Options available OFF On Alert Only Default setting is On ASF WatchDog Timer Enable Disable WatchDog Timer Options available Enabled Disabled Default setting is Disabled ...

Страница 43: ... Setup 5 2 5 Super IO Configuration Parameter Description Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Configuration Press Enter for configuration of advanced items ...

Страница 44: ...able Enabled Disabled Default setting is Enabled Devices Settings Note2 Displays the Serial Port 1 device settings Change Settings Note2 Select an optimal settings for Super IO Device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Note1...

Страница 45: ... Default setting is Enabled SYS FAN1 2 3 Fail Warning Options available Enabled Disabled Default setting is Disabled CPU FAN Speed Control Options available Full Speed Standard Mode Default setting is Standard Mode SYS FAN1 2 3 Speed Control Options available Full Speed Standard Mode Default setting is Standard Mode ...

Страница 46: ...ption Wake System from S5 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time is selected system will wake on the hr min sec specified Default setting is Disabled 5 2 7 S5 RTC Wake Settings ...

Страница 47: ...abled COM Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM Console Redi rection is set to Enabled Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is ANSI Bits per second Selects the transfer rate for console redirection Options available 9600 1...

Страница 48: ... Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Default setting is None VT UTF8 Combo Key Support Enable...

Страница 49: ...nsole Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled Serial Port for Out of Band EMS Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when Serial Port for Out of Band Managemen...

Страница 50: ...data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Software Xon Xoff Default setting is None ...

Страница 51: ...abled PPC Adjustment Options available PState 0 PState 1 PState 2 Default setting is PState 0 NX Mode Enable Disable No execute page protection Function Options available Enabled Disabled Default setting is Enabled SVM Mode Enable Disable the CPU Virtualization Options available Enabled Disabled Default setting is Enabled C state Controls IO based C state generation and DF C states Options availab...

Страница 52: ... the Ipv4 HTTP feature Options available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Note Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled PXE boot wait time Note Wait time in seconds to press ESC key to abort ...

Страница 53: ...ssages Sets display mode for Option ROM Options available Force BIOS Keep Current Default setting is Force BIOS INT19 Trap Response Options available Immediate Postponed Default setting is Immediate HDD Connection Order Options available Adjust Keep Default setting is Adjust Boot option filter Controls Legacy UEFI ROMs priority Options available UEFI and Legacy Legacy only UEFI only Default settin...

Страница 54: ...6 7 8 9 10 Until Press ESC Default setting is 5 Error Message Report Info Error Message Enable Disable Info Error Message support Options available Enabled Disabled Default setting is Enabled Summary Screen Note Enable Disable Summary Screen support Options available Enabled Disabled Default setting is Disabled Delay Time Sets the POST Report wait time Options available 0 1 2 3 4 5 6 7 8 9 10 Unti...

Страница 55: ... 55 BIOS Setup 5 2 13 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system ...

Страница 56: ... 56 BIOS Setup 5 2 14 Offboard SATA Controller Configuration Parameter Description Offboard SATA Controller Configuration Displays the information on your PCIe SATA controllers PCIe SSD if installed ...

Страница 57: ... 57 BIOS Setup 5 2 15 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type ...

Страница 58: ... 58 BIOS Setup 5 2 16 Realtek PCIe GBE Family Controller Parameter Description Realtek PCIe GBE Family Controller Press Enter to view the Network Interface Controller information ...

Страница 59: ...phics IFD Ext Graphics PEG Default setting is Ext Graphics PEG Onboard LAN1 2 Enable Disable Onboard LAN Options available Disabled Enabled Default setting is Enabled Onboard Audio Enable Disable Onboard audio Options available Disabled Enabled Default setting is Enabled Restore AC Power Loss Selects AC power state when power is re applied after a power failure Options available Power Off Power On...

Страница 60: ...Mode Options available AHCI RAID Default setting is AHCI CPU Performance Changes CPU performance mode Options available Standard Mode Performance Mode Default setting is Standard Mode AMD PSP KVM Configuration Press Enter to configure advanced items ...

Страница 61: ...able AMD PSP KVM feature Options available Disabled Enabled Clear Default setting is Disabled Resolution select for AMD PSP KVM feature Options available 1280 x 1024 1024 x 768 Default setting is 1024 x 768 IPv4 IP Assignment Options available Dynamic Static Default setting is Dynamic Note Advanced items prompt when this item is defined ...

Страница 62: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Страница 63: ...tions that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually load its keys f...

Страница 64: ...te Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Update Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Update Append ...

Страница 65: ...ber of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is On Full Screen LOGO Show Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled BOOT Option Priorities B...

Страница 66: ...ard Changes and Reset Discards changes made and exits the BIOS setup Options available Yes No Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these settings the system might not function properly O...

Страница 67: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 7 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource re...

Отзывы: