background image

- 100 -

BIOS Setup

5-3-3-1-6 

Phy Configuration

Parameter

Description

Phy Configuration

PMU Training

Press [Enter] to configure PMU Training.

 

Š

DFE Read Training

 

– Perform 2D Read Training with DFE on.

 

– Options available: Auto, Enable, Disable. Default setting is 

Auto

.

 

Š

FFE Write Training

 

– Perform 2D Write Training with FFE on.

 

– Options available: Auto, Enable, Disable. Default setting is 

Auto

.

 

Š

PMU Pattern Bits Controls

 

– Options available: Auto, Manual. Default setting is 

Auto

.

Содержание S472-Z30

Страница 1: ...S472 Z30 4U 50 Bay Single Processors Storage Server User Manual Rev 1 0...

Страница 2: ...and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short...

Страница 3: ...uide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any da...

Страница 4: ...y from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades dur...

Страница 5: ...charge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some...

Страница 6: ...3 1 Removing Chassis Cover 26 3 2 Removing and Installing the Fan Duct 27 3 3 Removing the Heat Sink 28 3 4 Installing the CPU 29 3 5 Installing the Memory 30 3 5 1 Eight Channel Memory Configuration...

Страница 7: ...SATA Configuration 70 5 2 13 Graphic Output Configuration 71 5 2 14 AMD Mem Configuration Status 72 5 2 15 Tls Auth Configuration 73 5 2 16 iSCSI Configuration 74 5 2 17 Intel R i350 Ethernet Controll...

Страница 8: ...iguration 129 5 6 4 IPv6 BMC Network Configuration 130 5 7 Security Menu 131 5 7 1 Secure Boot 132 5 8 Boot Menu 134 5 9 Save Exit Menu 136 5 10 BIOS Recovery 137 5 11 BIOS POST Beep code AMI standard...

Страница 9: ...dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before...

Страница 10: ...Supported NOTE The system will take extra time to boot as it goes through RoT authentication Socket Socket Security Security Memory Total 16 x DIMM slots DDR4 memory supported only 8 Channel memory a...

Страница 11: ...e drive bays Recommended SAS cards Broadcom 9500 16i Tri Mode Storage Adapter Broadcom 9560 8i Tri Mode Storage Adapter Socket Socket Security Security RAID Depends on SAS add on Card Socket Socket Se...

Страница 12: ...ecurity Front I O 2 x USB 3 0 1 x Power button with LED 1 x ID button with LED 1 x Reset button 1 x System status LED 2 x LAN activity LEDs 1 x HDD activity LED Socket Socket Security Security Rear I...

Страница 13: ...rd HTML5 KVM Sensor Monitor Voltage RPM Temperature CPU Status etc Sensor Reading History Data FRU Information SEL Log in Linear Storage Circular Storage Policy Hardware Inventory Fan Profile System F...

Страница 14: ...14 Hardware Installation 1 3 System Block Diagram...

Страница 15: ...Chapter 2 System Appearance 2 1 System Overview No Description 1 Front Panel Buttons and LEDs 2 Front 2 5 Hard Drives 3 Side 3 5 Hard Drives Cover 4 System Cover 5 Power Supply Units 6 Rear 2 5 Hard D...

Страница 16: ...6 Rear System LAN LEDs and Button for a detailed description of the function of the LEDs 2 2 Front View No Description 1 Front Panel LEDs and Buttons 2 USB 3 0 Port x 2 3 2 5 HDD Bays HDD 0 HDD 1 HDD...

Страница 17: ...e No Description 1 3 5 HDD Bays Right Side No Description 1 3 5 HDD Bays HDD 24 HDD 25 HDD 26 HDD 27 HDD 28 HDD 29 HDD 30 HDD 31 HDD 32 HDD 33 HDD 34 HDD 35 1 HDD 36 HDD 37 HDD 38 HDD 39 HDD 40 HDD 41...

Страница 18: ...not powered on or in ACPI S5 state power off System is in ACPI S4 state hibernate mode 4 HDD Status LED Amber On Indicates locating the HDD Blink Indicates accessing the HDD N A On Indicates HDD error...

Страница 19: ...Recovering BIOS Active Flash Blinks Blue 4 times per second Blinks Green 4 times per second Authentication AUTH Pass Recovering BIOS Active Flash OFF OFF BMC AUTH pass after doing recovery BIOS AUTH p...

Страница 20: ...ken or not exited result in Microchip CEC1702 cannot load EC FW for authentication 2 1 Authentication fail include below scenarios Configuration table is missing or modified Public key is missing or m...

Страница 21: ...tivate system identification 2 1GbE Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 3 1GbE Link Activity LED Green On Link between system and network or no a...

Страница 22: ...Hz Green Blinking Power supply firmware updating mode Amber AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Power supply critical event causing shut...

Страница 23: ...Removed HDD Slot LED on Back Panel Disk LED Removed HDD Slot RAID SKU No RAID configuration via HBA RAID configuration via HW RAID Card or SW RAID Card HDD Access HDD Present No Access BLINK 2 BLINK 2...

Страница 24: ...1 Green LED1 Red LED2 Blue Indicator Drive activity Drive locate fault rebuild Drive present Behavior BLINK Drives is active ON or OFF Idle depend on drive ON Fault BLINK 4Hz Locate BLINK 1Hz Rebuild...

Страница 25: ...u are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal s...

Страница 26: ...urned on or connected to AC power Follow these instructions to remove the chassis cover 1 Press the button to unlock the handle 2 Pull the grip handle to open the panel cover 3 Slide the cover towards...

Страница 27: ...and Installing the Fan Duct Follow these instructions to remove install the fan duct 1 Lift up to remove the fan duct 2 To install the fan duct align the fan duct with the guiding groove Push down th...

Страница 28: ...f the server before you start installing components may cause serious damage Do not attempt the procedures described in the following sections unless you are a qualified service technician Follow thes...

Страница 29: ...ician Follow these instructions to install the CPU 1 Loosen the three captive screws securing the CPU cover in sequential order 1 g 2 g 3 2 Flip open the CPU cover 3 Remove the CPU carrier from the CP...

Страница 30: ...M_P0_D1 DIMM_P0_F0 DIMM_P0_F1 DIMM_P0_G0 DIMM_P0_G1 DIMM_P0_H0 DIMM_P0_H1 DIMM_P0_E0 DIMM_P0_E1 Read the following guidelines before you begin to install the memory Make sure that the motherboard supp...

Страница 31: ...c clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 3 5 3 Processor and Memory Module Matrix Table Processor a...

Страница 32: ...Population Two DIMM per Channel DIMM Type DIMM Population Max EPYC 7003 DDR Frequency MHz DIMM 0 DIMM 1 RDIMM 1R 3200 1R 1R 2933 2R or 2DR 3200 1R 2R or 2DR 2933 2R or 2DR 2R or 2DR 2933 LRDIMM 4DR 32...

Страница 33: ...n disconnected from the server prior to installing a PCIe card Failure to observe these warnings could result in personal injury or damage to equipment Follow these instructions to install PCI Expansi...

Страница 34: ...ctor on the backplane Follow these instructions to install a 3 5 hard disk drive 1 Loosen the thumbscrew securing the left right side chassis cover 2 Open the left right side cover 3 Press the release...

Страница 35: ...ing stud on the HDD tray 5 Slide the hard disk drive into the HDD tray 6 Reinsert the HDD tray into the slot and close the locking lever 1 2 3 4 5 Rear Side 1 Press the release button 2 Extend the loc...

Страница 36: ...uring the system fan cage 2 Remove the system fan cage 3 Reverse the previous steps to install the replacement fan assembly Voltages can be present within the server whenever an AC power source is con...

Страница 37: ...upply 1 Press the retaining clip on the right side of the power supply along the direction of the arrow 2 Pull out the power supply handle at the same time and pull out the power supply 3 Insert the r...

Страница 38: ...38 System Hardware Installation 3 10 Cable Routing HDD Backplane Board Signal Cable Power Cable PSU 2x SATA Cable P1 SATA0 P2 SATA1 SATA0...

Страница 39: ...to SATA cable Reserved SAS Card SL_CN1 SL_CN2 SL_SAS1 SL_SAS3 SL_SAS2 SL_SAS0 SlimLine to SATA cable RAID CARD SL_SAS0 SL_SAS1 SL_SAS2 SL_SAS2 SL_SAS1 SL_SAS0 Reserved SlimLine to NVMe Cable 12 15 U2...

Страница 40: ...ystem Hardware Installation SlimLine to NVMe Cable 16 19 CNV3134 CNV3134 U2_16 U2_17 U2_18 U2_19 U2 A U2 B U2 C U2 D SlimLine to NVMe Cable 20 23 U2_20 U2_21 U2_22 U2_23 CNV3134 CNV3134 U2 A U2 B U2 C...

Страница 41: ...18 17 19 20 21 24 22 7 8 12 23 Item Description 1 BMC Firmware Readiness LED 2 OCP Mezzanine Connectors 3 2 x 12 Pin Main Power Connector 4 Battery Socket 5 2 x 4 Pin Power Connector for CPU 6 2 x 4...

Страница 42: ...le Connector 16 PCIe x16 Slot Gen3 x16 x8 17 PCIe x8 Slot Gen3 x0 x8 18 PCIe x16 Slot Gen4 x16 19 PCIe x16 Slot Gen4 x16 20 PCIe x16 Slot Gen4 x8 21 PCIe x16 Slot Gen4 x16 22 PCIe x16 Slot Gen4 x16 23...

Страница 43: ..._P0_C1 DIMM_P0_D0 DIMM_P0_D1 DIMM_P0_F0 DIMM_P0_F1 DIMM_P0_G0 DIMM_P0_G1 DIMM_P0_H0 DIMM_P0_H1 DIMM_P0_E0 DIMM_P0_E1 HSMB_SEL PMBUS_SEL ON BIOS Recovery Mode Normal Default Normal Default BIOS Defined...

Страница 44: ...Connector U_2_9 11 Slimline SAS Connector U_2_10 12 Slimline SAS Connector U_2_11 13 Slimline SAS Connector U_2_12 14 Slimline SAS Connector U_2_13 15 Slimline SAS Connector U_2_14 16 Slimline SAS Co...

Страница 45: ...2 SATA 6Gb s Signal 4 3 3 Right Side CBPD2C1 Item Description 1 Slimline SAS 4i Connector SL_SAS0 SATA 6Gb s Signal 2 Slimline SAS 4i Connector SL_SAS1 SATA 6Gb s Signal 3 Slimline SAS 4i Connector SL...

Страница 46: ...with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected re...

Страница 47: ...f the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to...

Страница 48: ...displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen H...

Страница 49: ...rmation CPU Brand String CPU Speed Processor Core Microcode Patch Displays the technical specifications for the installed processor s Total Memory Note2 Displays the total memory size of the installed...

Страница 50: ...dress Note Displays LAN MAC address information System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format Note The...

Страница 51: ...u options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Select is set to UEFI Default When Boot...

Страница 52: ...le BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable SPI TPM Suppo...

Страница 53: ...53 BIOS Setup 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable...

Страница 54: ...54 BIOS Setup 5 2 3 Legacy Video Select Parameter Description OnBrd Ext VGA Select Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard...

Страница 55: ...4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 2 Configuration Press Enter for configuration...

Страница 56: ...56 BIOS Setup 5 2 4 1 Serial Port 1 2 Configuration...

Страница 57: ...Settings Note2 Select an optimal settings for Super IO Device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5...

Страница 58: ...Settings Parameter Description Wake System from S5 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time is selected system will wake on the hr min sec speci...

Страница 59: ...Serial Over LAN COM2 Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN COM2 Console Redirection is set to Enable...

Страница 60: ...ailable 1 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flo...

Страница 61: ...S Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default se...

Страница 62: ...a loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the fl...

Страница 63: ...onfiguration Parameter Description SVM Mode Enable Disable the CPU Virtualization Options available Enabled Disabled Default setting is Enabled CPU 0 1 Information Press Enter to view the memory infor...

Страница 64: ...64 BIOS Setup 5 2 8 PCI Subsystem Settings...

Страница 65: ...setting is Enabled MEZZ Max Link Speed Options available Auto Maximum Gen1 Gen2 Gen3 Default setting is Auto Onboard LAN Controller Note2 Enable Disable the onboard LAN devices Options available Enabl...

Страница 66: ...t Enable Disable the Legacy USB support function AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications Options av...

Страница 67: ...t value during a USB mass storage device reset Options available 10 sec 20 sec 30 sec 40 sec Default setting is 20 sec Device power up delay Maximum time the device will take before it properly report...

Страница 68: ...he Ipv4 HTTP feature Options available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enab...

Страница 69: ...ration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system NVMe LED Control Enable Disable the NVMe LED Control Options available System Default Disabled Enabled...

Страница 70: ...70 BIOS Setup 5 2 12 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type...

Страница 71: ...13 Graphic Output Configuration Parameter Description Output Device Type Selects output device type Options available First loaded Device Onboard Device External Device Specific Device Default setting...

Страница 72: ...72 BIOS Setup 5 2 14 AMD Mem Configuration Status Parameter Description CPU 0 Press Enter to view the memory configuration status related to CPU 0...

Страница 73: ...iguration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit...

Страница 74: ...Configuration Parameter Description iSCSI Initiator Name Add an Attempt Press Enter to configure advanced items Delete Attempts Press Enter to configure advanced items Change Attempt Order Press Enter...

Страница 75: ...75 BIOS Setup 5 2 17 Intel R i350 Ethernet Controller...

Страница 76: ...e numeric keys to adjust desired values up to 15 seconds UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for th...

Страница 77: ...g VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrea...

Страница 78: ...nabled Disabled Default setting is Disabled Enable DHCP Note Options available Enabled Disabled Default setting is Disabled Local IP Address Note Press Enter to configure local IP address Local NetMas...

Страница 79: ...for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consecutive Neighbor solicitation messages sent while performing Duplicate Address Detection on a...

Страница 80: ...tup 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related sub...

Страница 81: ...81 BIOS Setup 5 3 1 CPU Common Options...

Страница 82: ...Auto 253 ASIDs 509 ASIDs Default setting is Auto SEV ES ASID Space Limit Control Space limit control for SEV ES ASIDs Options available Auto Manual Default setting is Auto Streaming Stores Control Ena...

Страница 83: ...to zero for analysis purpose as long as OS supports it Options available Disabled Enabled Auto Default setting is Auto REP MOV STOS Streaming Allows REP MOVS STOS to use non caching streaming stores f...

Страница 84: ...ted you can control the number of CCDs to be used and the number of cores to be used CCD Control Options available Auto 2 CCDs 3 CCDs 4 CCDs 6 CCDs Default setting is Auto Core Control Options availab...

Страница 85: ...le Default setting is Auto L1 Region Prefetcher Use memory access history to fetch additional lines when the data access for a given instruction tends to be followed by other data accesses Enable Disa...

Страница 86: ...86 BIOS Setup 5 3 1 3 Core Watchdog Parameter Description Core Watchdog Core Watchdog Timer Enable Enable Disable CPU Watchdog Timer Options available Auto Enabled Disabled Default setting is Auto...

Страница 87: ...Disable DF Sync Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Freeze DF module queues on error Options available Auto Enabled Disabled Default...

Страница 88: ...Poison scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber control Enable Disable the Redirect scrubber control feature Options available Auto E...

Страница 89: ...ions available Auto 256Bytes 512Bytes 1KB 2KB Default setting is Auto 1TB remap Enable Disable to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configura...

Страница 90: ...Options available Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLI...

Страница 91: ...CAKE CRC perf bounds Control Options available Auto Manual Default setting is Auto 4 link xGMI max speed Specifies the max speed of 4 link xGMI Default setting is Auto 3 link xGMI max speed Specifies...

Страница 92: ...Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced...

Страница 93: ...Settings Options available Auto Enabled Default setting is Auto DRAM Controller Configuration Press Enter to configure DRAM Controller Configuration CAD Bus Configuration Press Enter to configure CAD...

Страница 94: ...ue 6 1 UrgRefLimit Specifies the value Valid value 6 1 DRAM Maximum Activate Count Options available Untested MAC 700K 600K 500K 400K 300K 200K Unlimited MAC Auto Default setting is Auto DRAM Refresh...

Страница 95: ...guration CAD Bus Timing User Controls Setup time on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto CAD Bus Drive Strength User Controls Drive Strength on CAD b...

Страница 96: ...1 3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Controls Specifies the mode for drive strength to Auto or Manual Options available Auto Manual Defa...

Страница 97: ...tion Options available Auto Enabled Disabled Default setting is Auto Max Parity Error Replay Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurab...

Страница 98: ...ems DRAM ECC Symbol Size Configures the DRAM ECC Symbol Size Options available Auto x4 x8 x16 Default setting is Auto DRAM ECC Enable Enable Disable DRAM ECC When set to Auto it will set ECC to enable...

Страница 99: ...cription Security TSME Enable Disable transparent secure memory encryption Options available Auto Enabled Disabled Default setting is Auto Data Scramble Enable Disable Data Scrambling Options availabl...

Страница 100: ...Training DFE Read Training Perform 2D Read Training with DFE on Options available Auto Enable Disable Default setting is Auto FFE Write Training Perform 2D Write Training with FFE on Options availabl...

Страница 101: ...No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address...

Страница 102: ...DIMM Parameter Description NVDIMM Displays the information of the devices controllers if installed Disable NVDIMM N Feature Enable Disable NVDIMM N feature for memory margin tool Options available No...

Страница 103: ...te Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note Enable Disable to report 2D data eye results in ABL log fo...

Страница 104: ...ult setting is Vendor Tests Enabled PMU Mem BIST Test Select Note1 Selects the algorithms to use with PMU Mem BIST Default setting is Algorithm 1 2 3 4 5 Mem BIST Post Package Repair Type Note1 Select...

Страница 105: ...l function Options available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggr...

Страница 106: ...Worst Case Margin Granularity Configures Worst Case Margin Granularity Options available Per Chip Select Per Nibble Default setting is Per Chip Select Read Voltage Sweep Step Size Configures the step...

Страница 107: ...Enumeration ARI Forwarding Enable for each downstream port Options available Auto Enable Disable Default setting is Auto PCIe Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported device...

Страница 108: ...Data Link Feature Cap Enable Disable the data link feature capability Options available Auto Enabled Disabled Default setting is Auto CV test Enable Disable the running PCIECV tool support Options ava...

Страница 109: ...nly Options available Auto Manual Default setting is Auto EfficiencyModeEn Options available Auto Enabled Default setting is Auto Package Power Limit Control Selects use the fused PPT or set customize...

Страница 110: ...ed Default setting is Auto BoostFmaxEn Options available Auto Enabled Default setting is Auto EDC Current Tracking Options available Enable Disable Default setting is Disable LCLK Frequency Control Pr...

Страница 111: ...it of 0 indicates LOW severity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Auto Enabled Disabled Default setting is Auto NBIO SyncFlo...

Страница 112: ...d Default setting is Disabled SLINK Read Response Error Handling Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default setting is Log Errors in MCA Log Poison Data from SLINK Enabl...

Страница 113: ...rameter Description FCH Common Options AC Power Loss Options Press Enter for configuration of advanced items FCH RAS Options Press Enter for configuration of advanced items Miscellaneous Options Press...

Страница 114: ...Setup 5 3 5 1 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is L...

Страница 115: ...ALink RAS Support Enable Disable the ALink RAS Support Options available Auto Enabled Disabled Default setting is Auto Reset after sync flood Enables AB to forward downstream sync flood message to sys...

Страница 116: ...116 BIOS Setup 5 3 5 3 Miscellaneous Options Parameter Description Miscellaneous Options Boot Timer Enable Enable Disbale Boot Timer Options available Auto Enabled Disabled Default setting is Auto...

Страница 117: ...UART0 SOC UART1 Auto Default setting is Auto ABL Basic Console Out Control Note Enable Disable the Basic ConsoleOut function for ABL Options available Auto Enabled Disabled Default setting is Auto ABL...

Страница 118: ...ter Description Workload Tuning Workload Profile Select the profile for different workloads Default setting is Auto Performance Tracing Enable to allow capturing performance traces Options available A...

Страница 119: ...guration of advanced items iLA TraceMemoryEn Reserved 1M bytes MMIO space on 1M boundary when iLA TraceMemoryEn enabled Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn...

Страница 120: ...Period GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for unc...

Страница 121: ...Notify Type Selects the Notification type for CCIX deferred error Options available Polled SCI Default setting is Polled CCIX GHES Corrected Err Notify Type Selects the Notification type for CCIX cor...

Страница 122: ...er to access the related submenu screen Parameter Description PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enable Disable program all VR on MB Options available...

Страница 123: ...Setup 5 5 1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU 0 Information Press Enter to view information relate...

Страница 124: ...124 BIOS Setup 5 5 2 Fabric Resource Parameter Description Fabric Resource CPU 0 NBIO_ PCIe Bus Number Change CPU 0 NBIO_ PCIe Bus Number...

Страница 125: ...nable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Note Configures OS Watchdog Timer Options available 5 minutes 10 minutes 15...

Страница 126: ...vent Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configu...

Страница 127: ...se SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do N...

Страница 128: ...Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends...

Страница 129: ...IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays...

Страница 130: ...network during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by...

Страница 131: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user...

Страница 132: ...ll the applications that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login scre...

Страница 133: ...e Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Update Append...

Страница 134: ...lues Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is Off Quiet Boot Enable Disable showing the logo during POST Options available Enabled Di...

Страница 135: ...Option 1 2 3 4 5 Press Enter to configure the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI...

Страница 136: ...e so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of r...

Страница 137: ...corrupt the boot block can be used to restore the BIOS to a working state To restore your BIOS please follow the instructions listed below Recovery Instruction 1 Copy the XXX rom to USB diskette 2 Se...

Страница 138: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 11 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the A...