NOTE:
1. When the program crashes, simply close the program and
re-start it.
2. When there is an error within the settings, it will cause a
boot-up failure to the hardware, normally caused by over-
voltage or under-voltage protection. Therefore, to protect
the hardware, the system will not boot up. Please follow the
steps below to recover the system.
a. Remove the AC power cord.
b. Disconnect all the power connectors from the power
supply to motherboard, and the peripheral devices such
as the case fan, hard drives, and floppy drives, etc.
c. Use the USB converter kit to connect the Power supply
to another computer, and install Power Tuner.
d. Short the connector as in the image below, or use
ODIN GT PSU jump start kit to start ODIN GT power
supply.
e. Use the USB converter to connect the Odin GT power
supply to another computer.
f. Install Power Tuner in the computer, which the USB
cable connects to.
g. Connect the power cord into the Odin GT power
supply.
h. Now the Odin GT should automatically start.
i. Use Power Tuner to re-adjust the ODIN GT power
supply.
j. Now revise the steps, and ODIN GT should be able to
boot the system.
En