02
B
0d
Write to Parameter Table Address : 12 h
Get Power Mode : Real Control
02
A
0d
EXAMPLE
12
00
A1
8. GET REGISTER :
STX
B
CR
STX
A
CR
REGSTER
REGSTER
PARAM
CHKSUM
PARAM
Register Address . 2 Bytes Width ( 00h ~ FFh )
Set Parameters of Register
8-1. GET POWER MODE :
STX
B
CR
STX
A
CR
12
MODE
CHKSUM
Same 7-1. SET POWER MODE
Communication Protocol
8-2. GET AUTO POWER OFF TIME (LOW BYTE) :
STX
B
CR
STX
A
CR
10
SECL
CHKSUM
02
B
0d
02
A
0d
EXAMPLE
10
0A
B2
Get Parameter From Parameter Table Address : 10 h
Auto Power Off Time Period (Low Byte) : 5 Seconds
Same 7-2. SET AUTO POWER OFF TIME (LOW BYTE )
- 19 -