8.

 

Installation notes 
 

 

The wires of a pair can be connected straight or crossed. 

 

Maximum range of the G.hn connection depends on the type of cable used, the connection type and the environment. 
Typical values for a 0.5 mm twisted pair cable: connection possible up to approx. 600/800 metres (SISO/MIMO), 
maximum bandwidth of 1500 Mbit/s - up to approx. 100/200 metres (SISO/MIMO).  

 

For longer cables (up approx. 100-150m), the bandwidth can be increased by up to 15% (SISO) resp. up to 25% (MIMO) 
by adjusting the signal level. For this purpose, the "Range optimization model" must be set to "Long" in the web 
interface of both devices resp. the "LongRangeMode" setting must be activated in the G.hn switch. 

 

The negotiated bandwidth can be queried via the web interface of the devices (see point 11). 

 

The bandwidth split of the G.hn connection is variable. It can be set between 80/20% and 20/80%. In the factory setting, 
70% of the bandwidth is reserved for download (direction master to client) and 30% for upload (direction client to 
master). The allocation can be configured via master web interface (menu G.hn DownStream / UpStream Ratio) resp. via 
the G.hn switch. 

 

 

 
 
 

9.

 

Administration 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

10.

 

IP address 
 

The devices do not require IP addresses from the local network segment during operation, because they transmit the data 
traffic via the MAC addresses. In the factory setting, they do not obtain any addresses from the local DHCP server. 

 

If desired, static IP addresses can be configured or the DHCP client can be activated ("IP" menu in the web interface). 

 
 

11.

 

Query of the negotiated bandwidth 

 
The negotiated bandwidths for both transmission directions can be queried via web interface of each modem. The values 
shown are gross data transmission rates on physical layer (PHY). Transmission rate on application layer is 15-20% lower. 

IP-Adress: 192.168.10.252 (Master), 192.168.10.253 (Client). Login passwort: paterna, Factory reset passwort: betera 

 
 

Login via Webinterface 

 

Connect your computer to the G.hn modem via the GE 
port.. 

 

Assign a fixed IP address to your computer, e.g.  
192.168.10.100 (network mask 255.255.255.0). 

 

Open a web browser and connect to 192.168.10.252 or 
192.168.10.253 

 

Login with the standard password: paterna 

 

It is possible to loop through an analogue telephone line on the same line parallel to the G.hn signal. To do this, 
connect the telephone line and the telephone to the PHONE connections on the G.hn master and G.hn client. 

Содержание G4202T

Страница 1: ...This enables the central administration of all G hn components 2 Package content G4202T Master or G4202T Client DC 12V 1A Power adapter RJ11 RJ11 telephone cable 1 5m 4 wire SISO and MIMO TAE F RJ11 plug 4 pole SISO and MIMO 3 Technical data Dimensions 103 66 27 mm Weight 0 19 kg Operating temperature 0 C 40 C Power consumption 3 Watt 4 G hn Specification G hn Wave2 2 200 MHz Connection type SISO ...

Страница 2: ...e G hn connection can be established either via one wire pair connection type SISO G hn profile PHONE 200MHz or via two wire pairs connection type MIMO G hn profile PHONE 100MHz MIMO The connection type must be configured via web interface in both modems or via the G hn switch The default setting is one wire pair connection PHONE 200MHz Wire assignment SISO Wire assignment MIMO ...

Страница 3: ...m Ratio resp via the G hn switch 9 Administration 10 IP address The devices do not require IP addresses from the local network segment during operation because they transmit the data traffic via the MAC addresses In the factory setting they do not obtain any addresses from the local DHCP server If desired static IP addresses can be configured or the DHCP client can be activated IP menu in the web ...

Страница 4: ...gs are forwarded transparently by default External Ethernet switches can be used to manage VLANs Instead of external Ethernet switches the VLAN configuration can be done by the manageable G hn switches G4200 8T 4T and G4224T Both Ethernet ports of the G4202T modem can be configured independently ...

Страница 5: ...in the network IGMP Snooping must be activated in the multicast configuration 14 Guarantee We provide a 24 month warranty on all products purchased from us You can find complete warranty conditions at https gigacopper net web en Guarantee_declaration pdf ...

Отзывы: