GIFAS-ELECTRIC GmbH
· Dietrichstrasse 2 · Postfach · CH-9424 Rheineck
5
Flash
LED
Stylus functions:
Icon
Function
Description
5
Main switch
On / Off
To switch on / switch off the lamp:
Each time you switch on the lamp, the memory function is
activated (setting which was last chosen).
6
Mode of
operation
The switching of the operating modes "long distance
beam - working lamp - high beam" happens at keypress
and the appropriate symbol in the display lights up.
Short keypress: recover of the factory setting
7
Brightness
The dimming function will be activated through keypress.
From minimum trough to maximum and back to minimum
Further functions through key sequences:
Blinking function:
The common operation of
(
5)
and
(
7)
activates the blinking function of the lamp.
The blinking frequency can be increased and decreased by pressing the main switch continually
(
5)
.
Morse function:
If the lamp is switched off, you can generate some light impulses (morse code) by a
keypress on
(
7)
. The mode "auxiliary lamp" will be activated automatically as long as the button is
pressed.
Instruction manual: battery charger
Flash
LED
The battery charger for your
Flash
LED
completes the function of this lamp. It can be used on table
as well as wall-mounted. By using a padlock (accessory), the
Flash
LED
is safe from theft whilst in the
battery charging station.
Settings for emergency light:
Emergency light
Description
ON = factory setting
If the supply voltage fails, the lamp will be switched on in the light-
ning mode "high beam" until the battery threshold reaches or the
supply voltage is available again (3.5 h light duration).
OFF
If the supply voltage fails, the lamp stays switched off. Advisable for
recharging from car battery.
Voltage range
Value
Version 230 V
220 - 240 VAC
Version low voltage
12 - 24 VDC ± 10%
Emergency light function:
The emergency light function will be activated by changing the magnetic switch to
Emergency Light ON
Содержание flashLED