1  General information 

1.1  Marking concept for hazards and hints 

 

Hazard 

Hazardous situation which will cause serious injury or even death if it is not prevented. 

 

Caution 

Hazardous situation which could cause slight to moderate injury if it is not prevented. 

 

Hint

 

Indicates information which does not concern personal injury, e.g. hints in respect of material damage. 

 

Protective measures 

Increase safety by applying a protective measure. 

1.2  Responsibilities of the operator 

-

 

Make sure that this document is always kept in a safe place in a legible form together with the product. 

-

 

Read these instructions carefully before first start-up of the product. 

-

 

This product has been developed and produced exclusively for the use indicated in these documents. 
Every other use, which is not mentioned explicitly, could affect the intactness of the product and/or 
could constitute a source of danger. 

-

 

The manufacturer rejects any liability for damage which has been caused by incorrect or non-intended 
use of the product. 

-

 

In countries, which do not belong to the European Community, the national legal reference regulations 
as well as the standards and regulations applicable in these countries have to be observed for warranty 
of a corresponding safety level. 

-

 

The installation has to be carried out according to the applicable regulations. 

-

 

The manufacturer assumes no liability for inexpert  execution of installation as  well  as deformations 
which may occur during operation. 

-

 

The electric power supply has to be switched off before executing any action on the installation. 

-

 

Exclusively original parts of the manufacturer shall be used for maintenance. Maintenance work may 
be carried out by qualified staff only. 

-

 

All procedures which are not explicitly mentioned by the manufacturer in the instructions are not per-
mitted. 

-

 

The packing material must not be stored within the reach of children as it could be a potential source 
of danger. 

 

Содержание 1970W

Страница 1: ...H Modified 08 07 2020 roen Object ID 1144626 Floor socket outlets FONTO Manual VERSION MODIFICATIONS 1 0 Creation of the document 1 1 More detailed information in chapter 3 and 4 1 2 Complement chapter 4 07 02 2020 roen 1 3 Complement FONTO 8000 08 07 2020 roen ...

Страница 2: ...n conditions 5 3 Installation examples FONTO 6 3 1 FONTO 2290 6 3 2 FONTO 2295 6 3 3 FONTO 3290 7 3 4 FONTO 3295 7 3 5 FONTO 3301 8 3 6 FONTO 3308 8 3 7 FONTO series 4000 9 3 8 FONTO 8000 10 3 9 FONTO 1970D 11 3 10 FONTO 1970W 11 3 11 FONTO 3970W 12 3 12 FONTO 1975 12 3 13 Please note 12 4 Installation examples FONTO levelable 13 5 Connection Handling floor sockets FONTO 14 5 1 FONTO 1970W 15 5 2 ...

Страница 3: ...ffect the intactness of the product and or could constitute a source of danger The manufacturer rejects any liability for damage which has been caused by incorrect or non intended use of the product In countries which do not belong to the European Community the national legal reference regulations as well as the standards and regulations applicable in these countries have to be observed for warran...

Страница 4: ... 2 5 kV Temperature range 25 C to 40 C Max relative humidity 100 at 25 C decreasing linearly to 50 at 40 C Max Altitude 2000m above sea level by using above 2000m consult the producer Pollution degree 3 Transport and Storage Please only use grab handle or lifting eyes No special storage Be aware that the packaging is not damaged Cleaning If dirty clean with cleaning tissue or brush Do not use abra...

Страница 5: ...nction of the floor outlets following points should be noted For the assembly of the floor socket a fixed base must be present A montage of floor socket in lots soil gravel sand is not allowed The cable glands must be suitable for the particular cable diameter Before closing the floor socket remove all pollution The floor sockets must be cleaned regularly from dirt All seals should be checked for ...

Страница 6: ...8 07 2020 roen Object ID 1144626 3 Installation examples FONTO 3 1 FONTO 2290 1 Floor covering 2 Backfill 3 2x cable gland M25 across 4 Mortar bed to align 3 2 FONTO 2295 1 Floor covering 2 Backfill 3 2x cable gland M25 beside 4 Mortar bed to align 5 1x cover cable outlet ...

Страница 7: ...KHSH Modified 08 07 2020 roen Object ID 1144626 3 3 FONTO 3290 1 Floor covering 2 Backfill 3 2x cable gland M25 beside 4 Mortar bed to align 3 4 FONTO 3295 1 Floor covering 2 Backfill 3 2x cable gland M25 beside 4 Mortar bed to align 5 2x cover cable outlet ...

Страница 8: ... 2x cable gland M25 beside 4 Mortar bed to align 5 2x cover cable outlet Hint The cover is removable 3 6 FONTO 3308 1 Floor covering 2 Backfill 3 2x cable gland M25 beside 4 Mortar bed to align 5 Recessed lid for 9 mm stone 6 2x cover cable outlet Hint The customer is responsible for fixing the stone in the recess There are no special requirements ...

Страница 9: ...r covering 2 Backfill under floor 3 2x cable gland M25 4 4x levelling feet M8 FONTO 4290 FONTO 4295 FONTO 4301 FONTO 4308 5 Cover cable outlet 6 Recessed lid for floor covering Hint FONTO 4290 4295 closed IP20 FONTO 4290 4295 hinged cover FONTO 4301 4308 closed IP20 FONTO 4301 4308 Removable cover FONTO 4308 for several floor coverings Adjustable ca 6mm ...

Страница 10: ...3 8 FONTO 8000 1 Floor covering 2 Backfill under floor 3 3x cable gland M25 4 4x levelling feet M8 5 Cable outlet on cover Hint FONTO 8301 removable cover FONTO 8308 removable cover for various floor coverings level adjustable after installation approx 6mm approx 95mm approx 125 165mm 90 100mm 240mm 240mm ...

Страница 11: ...ject ID 1144626 3 9 FONTO 1970D 1 Floor covering 2 Backfill 3 2x cable gland M25 across 4 Mortar bed to align Special screwable lid 3 10 FONTO 1970W 1 Floor covering 2 Backfill 3 2x cable gland M25 underside of the housing 4 Mortar bed to align 5 Silicone joint 6 Water height maximum 20 mm ...

Страница 12: ...3 2x cable gland M25 across 4 Mortar bed to align 5 2x cable gland M32 underside of the housing 6 Levelling support alternative to mortar bed 7 Water protection pipe with 2x cable outlet 8 View without cover 3 13 Please note Ensure that the floor socket is the same level with the top edge of the floor covering The floor sockets must not be driven over with grinding machines when closed It is gener...

Страница 13: ...pipes or cables 4 Put on the protection cap part of the packaging 5 Backfill the socket with load bearing material concrete mortar 6 Remove the protection cap before the floor covering is laid 7 Use the levelling screws to make a fine adjustment to the floor level 8 Caulk the joint between the floor socket and the floor covering Hint With the inner levelling screw a difference of 6mm can be compen...

Страница 14: ...dling floor sockets FONTO Opening of floor outlet i e removal of the insert holder 1 Open the cover of the junction box 2 Unscrew the insert holder 3 Pull out insert holder 4 Connect the sockets The replacement and closing takes place in reverse order Hint The metal socket must be properly connected to the earth conductor ...

Страница 15: ...Floor socket outlets FONTO Page 15 18 Created 12 12 2016 KHSH Modified 08 07 2020 roen Object ID 1144626 5 1 FONTO 1970W 5 2 FONTO 3970W 1 to open to fix 2 ...

Страница 16: ...utlet i e removal of the insert holder 1 Unscrew the cover with an allen Key size 5 counterclockwise 2 Extract the water protection tube 3 To connect the sockets you have to remove the 4 pc screws at the insert holder allen Key size 3 4 Pull out insert holder to connect the sockets The replacement and closing takes place in reverse order ...

Страница 17: ...Floor socket outlets FONTO Page 17 18 Created 12 12 2016 KHSH Modified 08 07 2020 roen Object ID 1144626 5 3 1 Handling FONTO 175 1 4 0 ...

Страница 18: ...H 9424 Rheineck 49 2137 105 0 39 58 497 82 11 43 6225 7191 0 41 71 886 44 44 49 2137 105 230 39 58 493 99 24 43 6225 7191 561 41 71 886 44 49 www gifas de www gifas it www gifas at www gifas ch verkauf gifas de info gifas it verkauf gifas at info gifas ch 6 2 Imprint GIFAS ELECTRIC GmbH CH 9424 Rheineck www gifas ch Technical changes and errors reserved These installation instructions are the prop...

Отзывы: