background image

GENERAL WARNINGS

These warnings constitute an integral and essential part of the product and must be issued to the user. 
Carefully read the warnings in this paragraph since they supply important information concerning 
safety of installation, use and maintenance. Safely keep this handbook for any further consultation.

INSTALLATION WARNINGS

Installation, electrical connections and adjustments must be carried out  by qualified technicians in 
observance of Good Techniques and in compliance with the regulations in force, in accordance with the 
instructions below. Carefully read the instructions in this handbook before starting installation of the 
product. Incorrect installation may cause damage to persons, animals or things, for which Gi.Bi.Di. 
cannot be held responsible. Before connecting the instrument, ensure that the rating indicated on the 
plate corresponds to that of the mains. Do not install the product in an explosive environment; the 
presence of inflammable gas or fumes constitute a serious danger. The packaging materials must not be 
littered and must be kept away from children since they are potential sources of danger. Before starting 
installation, check that the product is undamaged. Before installing the automation, make the necessary 
structural modifications relative to safety clearances and protection and/or segregation of the shearing, 
entrainment and crushing zones, and danger zones in general. Check that the existing structure has the 
necessary requirementsof robustness and stability Gi.Bi.Di. is not liable for inobservance of Good 
Techniques in the construction of the doors and gates to be motorized, or in the event of deformations 
occurring during use. The safety devices (photocell, sensitive frames, emergency stop, etc.) must be 
installed in consideration of the regulations in force, the installation environment, the functioning logic 
of the system, and the forces developed by the automatic door or gate. The safety devices must comply 
with current regulations, and allow protecting any crushing and entrainment zones, and danger zones in 
general. Each system must visibly be identified (sign, label, etc.) by the product identification data and 
any automatic remote control commands present. At the time of installation, an omnipolar switch must 
be fitted with a contact opening distance equal to or greater than 3 mm. Check that upstream of the 
electrical system a differential switch with a threshold of 0.03A is installed. Connect the automation to 
an efficient earthing system as provided by the safety regulations in force. Gi.Bi.Di. declinesall
responsibility for the safety and good functioning of the automation in case the components used in the 
system are not those specified by the manufacturer.

UTILIZATION WARNINGS This product is intended only for such use for which it was 
expressly designed. Any other use is to be considered improper and therefore dangerous.
Gi.Bi.Di. cannot be held responsible for any damage caused by improper, incorrect and 
unreasonable use.

The installer must supply all the information relative to manual functioning of the system in case of 
emergency, and supply the user with the instruction manual. Avoid working near the hinges or moving 
mechanical devices, which may generate conditions of danger, since the body or garments are easily 
caught up and difficult to release. Do not enter the range of action of the automatic door or gate while 
in movement. Wait until it has completely stopped. Do not oppose the motion of the automatic door or 
gate since this may create dangerous conditions. Do not allow children to play or stand in the vicinity of 
the automatic door or gate. Keep the radio controls and/ or any other control device out of the reach of 
children to prevent involuntary activation of the automation.

MAINTENANCE AND REPAIR WARNINGS

In case of breakage and/or bad functioning of the product, switch it off, abstaining from any attempt at 
repair or direct intervention and contact qualified technicians only. Inobservance of the above may 
create dangerous conditions. Before carrying out any cleaning, maintenance or repair operations, 
disconnect the automation from the mains and any emergency batteries. To guarantee efficiency of the 
system and its proper functioning it is indispensable to follow the instructions of the manufacturer, 
having the periodical maintenance of the automation carried out by professionally qualified technicians. 
In particular, it is recommended to periodically check proper functioning of all the safety devices. For 
any product repairs or replacements, exclusively original spare parts as specified by the manufacturer 
must be used. Modifications or additions to an existing system must be made following the instructions 
of the manufacturer and using original parts as specified by the manufacturer. Installation, maintenance 
and repair operations must be noted on a maintenance card and the card kept by the user. 

Содержание MODO 110

Страница 1: ...HYDRAULIC OPERATOR MODO 110 110 L FOR SINGLE OR DOUBLE WING SWING GATES INSTRUCTIONS FOR INSTALLATION...

Страница 2: ...eam of the electrical system a differential switch with a threshold of 0 03A is installed Connect the automation to an efficient earthing system as provided by the safety regulations in force Gi Bi Di...

Страница 3: ...line to equipment 220 230V 50 60Hz cable with 3 conductors of min 1 5 mm follow regulations in force 8 220 230 V flashing light cable with 2 conductors of 1 5 mm 9 Shunt boxes 10 Photocell transmitte...

Страница 4: ...MOUNTING DIMENSIONS FOR THE SWING TO OPEN HOW TO WALL BRACKETS IN PILLARS OR TO WELD THEM ON A METAL STRUCTURE...

Страница 5: ...VELOCITY TIME TO OPEN UP TO 95 MAX FORCE MAX WORKING PRESSURE WORKING TEMPERATURE CYCLES HOUR FULL OPEN CLOSE CYCLES PER DAY GUARANTEED HYDRAULIC LOCK FOR SWING OF MAX LONG HYDRAULIC OIL 220 230V 50H...

Страница 6: ...the force by rotating counterclockwise the opening valve 1 and the closing valve 2 located under the operator WARNING When adjusting the force smoothly and radually rotate the valves without screwing...

Страница 7: ...MOUNTING THE ELECTROLOCK 1 Electrolock 2 electrolock fixing plate 3 Bolt hooker 4 Bolt hooking rabbet 5 Bolt 6 Key cylinder on request 7 Gate...

Страница 8: ...the provisions as per this Directive are in conformity with the regulations of the following other EEC Directives Directive 73 23 EEC Directive 93 68 EEC Low voltage Directive 89 336 EEC Directive 92...