22
23
BE24
BE24
UK
UK
14 - GATE TRAVEL LEARNING
The procedure has two phases, completely automatic: the first one of OPENING and CLOSING SPACES
learning and the second one of motors’ amperometric values learning.
If using only one motor, it must be connected to the terminals
M1.
Intervention of START, PED, PHOTO1, PHOTO2, SAFETY inputs during learning procedure will abort the
procedure and it will be necessary to repeat it from the beginning.
During learning procedure FLASHING LIGHT / WARNING LIGHT will be on.
Travel learning movement is slowed down (50%).
Learning procedure cannot be executed while running on battery.
Learning procedure:
Ÿ
Release the operators and move the gates to halfway their travel.
Ÿ
Lock the operators.
Ÿ
Check that the mechanical opening and closing stops are present on the ground (KUDA-AGO) or on the
operator (SERRA320-SNAPPER).
Ÿ
Remove any obstacles in the range of action of the automated device.
Ÿ
Check that leds L3, L4, L5 and L8 are on.
Ÿ
Press and release MEMO button.
Ÿ
Led L7 will come on, after 30 seconds of no user interaction the control board will quit learning procedure.
Ÿ
Within 30 seconds press again MEMO button in order to choose operator type. At the first stroke L7 will blink
once every 4 seconds and that means KUDA-AGO424E-AGO624E is the installed operator; at the second stroke
L7 will blink twice every 4 seconds and that means SERRA320-SNAPPER-AGO424E/S-AGO624E/S is the
installed operator. The operator selection sequence is cyclic.
Ÿ
Press button 1 of the radio control or give a START pulse from the terminal board.
Ÿ
Check that motors’ movement is in the correct direction (at the beginning in opening). On the contrary, block
the learning cycle with any safety device, invert the motor cables and repeat the procedure.
Movements during learning with 2 motors:
• Motor 1 opens until meeting the mechanical end-stops.
• Motor 2 opens until meeting the mechanical end-stops .
• 5 seconds pause.
• Motor 2 closes until meeting the mechanical end-stops.
• Motor 1 closes until meeting the mechanical end-stops.
• Full open-close cycle.
• End of learning; L7 will goes off.
Movements during learning with 1 motor:
• Motor 1 opens until meeting the mechanical end-stops.
• 5 seconds pause .
• Motor 1 closes until meeting the mechanical end-stops.
• It makes a complete manoeuvre, opening, 5 sec. pause and closing.
• End of learning; L7 goes off.
In case the learning procedure cannot be completed, please check LED L7 status (chapter 8).
13 - ONBOARD RADIO RECEIVER CONTROL
Storing a new transmitter in memory:
1 - Press and release
Learn
button.
2 - Led L6 will come on.
3 - Press button 1 of the transmitter to be stored for 2 seconds.
4 - The new transmitter is stored.
5 - Led L6 will stay on for another 5 seconds; during this period, you can store other transmitters, restarting from
step 3.
It ispossible to store up to 200 transmitters.
Clearing the memory:
1 - Press and hold down
Learn
button for 12 seconds.
2 - Led L6 will initially come on and then go off after 12 seconds.
3 - All the transmitters have now been deleted.
Assigning START and PED commands to the transmitter buttons:
Refer to
Figure 17-18
and DIP3 configuration.
The gate does not move after a START
command.
Ÿ
Check that L3, L4 and L5 are off; if not, check the devices connected to
terminals 19-20-21.
Ÿ
Check fuses.
Ÿ
Check that the battery voltage is not below 22VDC.
Ÿ
If L7 is blinking fast, learning procedure must be executed.
Transmitter range is short.
Check terminals 26-27 screws are tight.
Check and replace transmitter battery.
The gate does not fully open/close.
Check the motor and encoder connections.
The gate moves slowly.
Check the control board is not running on battery.
The gate moves slowly during opening.
The first maneuvre after a power failer is slowed and with automatic logic.
Meaning
Signal
Effect
Photo 2 intercepted in stand-by
in presence of START command
Edge intercepted in stand-by
in presence of START command
Edge intercepted in pause in presence of
START command or at the closing beginning
Low Battery before closing (21V).
Low Battery before opening or closing(16V).
5 fast flashings
3 slow flashings
3 slow flashings
4 slow flashing
4 slow flashing
When released it opens
Blocked closed door
Blocked open door
Blocked door
Blocked open door
Opening
Closing
0,8s ON, 0,8s OFF continuous
0,4s ON, 0,4s OFF continuous
The gate is opening