9 - DIP SWITCH DIP1
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
1_7
Enables pre-flashing of 3 seconds before motor activation during opening and closing.
Disables gate phase shift time.
ON
OFF
PRE-FLASHING
1_8
1_9
GATE PHASE
SHIFT TIME
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 3 seconds.
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Disables pre-flashing.
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 6 seconds.
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 9 seconds.
1_10
WATER HAMMER
Disables the water hammer function.
Enables the water hammer function during opening to help electric lock release.
Operation:
at the START command, the following will occur in sequence:
- electric lock activation;
- closing pulse of
1 sec
;
- opening;
- electric lock release after
2 sec
.
ON
OFF
10 - DIP SWITCH DIP2
Deceleration speed equal to
50%
of the maximum speed.
2_1
Deceleration speed equal to
30%
of the maximum speed.
ON
DECELERATION
SPEED
OFF
Speed during normal movement equal to
100%
of the maximum speed.
2_2
Speed during normal movement equal to
80%
of the maximum speed.
ON
MOVEMENT SPEED
OFF
Enables fast closing function.
Operation: Reduces the stand-by time to 3 seconds following interception and
subsequent freeing of the photocells. Active only on photocell 1.
2_3
Fast closing disabled.
ON
FAST CLOSING
OFF
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
Description
DIP
Status
Function
Description
DIP
Status
Function
changing this setting will
reset the control board and
a new learning cycle will be
required.