17
UK
BE24
Description
DIP
Status
Function
9 - DIP SWITCH DIP1
OFF
STEP-BY-STEP
WITH STOP
ON
AUTOMATIC
Operation in response to the START command:
Ÿ
Gate closed
OPENS
→
Ÿ
During opening
STOPS
→
Ÿ
Gate open
CLOSES
→
Ÿ
During closing
STOPS
→
Ÿ
After a STOP
inverts the motion
→
Operation in response to the START command:
Ÿ
Gate closed
OPENS
→
Ÿ
During opening
UNINFLUENTIAL
→
Ÿ
Gate open
Reloads the automatic closing time if automatic closing
→
is enabled, otherwise it closes.
OFF
ON
TERMINAL 21 AS
8K2 EDGE
Operation :
Ÿ
Gate closed
UNINFLUENTIAL
→
Ÿ
During opening
STOP
→
Ÿ
Gate open
UNINFLUENTIAL
→
Ÿ
During closing
STOP
→
Operation
Ÿ
Ÿ
During opening
Immediate motion inversion for 2s at low speed, when
→
contact is freed, the gate will continue with inverted movement at low speed.
Ÿ
Gate open
UNINFLUENTIAL
→
Ÿ
During closing
Immediate motion inversion for 2s at low speed, when
→
contact is freed, the gate will continue with inverted movement at low speed.
:
Gate closed
UNINFLUENTIAL
→
1_1
1_2
TERMINAL 21 AS
8K2 STOP
1_3
1_4
ANTI CRUSHING
SENSITIVITY
Very High sensitivity.
OFF
OFF
High sensitivity.
OFF
ON
Medium sensitivity.
ON
OFF
Low sensitivity.
ON
ON
1_5
1_6
PAUSE TIME
Automatic closing disabled.
OFF
OFF
30 seconds.
OFF
ON
60 seconds.
ON
OFF
120 seconds.
ON
ON
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.