9
UK
• Red warning LEDs of N.C. contacts (photo, safety dev, fcc, fca, stop).
• Green warning LEDs of N.O. contacts. (start, ped).
• Safety tests run before the opening and closing movements.
• Deceleration during opening and closing controlled by 2 supplementary magnets to be fitted in the desired position
at a minimum distance of at least 400 mm with respect to those used as limit switch (Fig.2). Deceleration is
adjustable with a trimmer (SLOW).
• Stop and motion inversion for 2 seconds after intervention of the safety devices. At the next Start pulse the motion
restarts in the obstacle freeing direction.
• Amperometric reading of motor absorption for the anti-crushing function both during normal operation and in slow
motion. (adjustable with AMP.FORCE and AMP.SLOW trimmers). The amperometric intervention determines
stopping and motion inversion for 2 seconds. At the next Start pulse the motion restarts in the obstacle freeing
direction.
• Pedestrian operation with fixed opening of 10 seconds. The condominium function and automatic closing are
always enabled.
• Provision for use with buffer batteries (accessory battery charger board).
• Test of battery charge status. During battery operation, an acoustic signal synchronised with the flashlight will be
activated. When the batteries are nearly flat and an opening command is given, the gate will open and remain thus.
Should the batteries not be sufficiently charged, the gate will not open.
SAFETY DEVICE POWER SUPPLY. Connection to this power supply allows TESTING the devices before motion.
The safety devices must be connected to this terminal and will be powered only during the operating cycle.
FEATURES / FUNCTIONS
SC24
SC24 / AS05010
230 Vdc single-phase 50/60 Hz
1
24 Vdc
24 Vdc 10W max
24 Vdc 3W max
24 Vdc 8W max including accessory power supply
Radio receiver
-20°C +60°C
Adjustable between 2 and 215 sec
240 sec. fixed
Rechargeable lead battery 24V 2Ah (2 x 12V 2Ah)
24 Vdc 8W max including safety device power supply
Electronic control unit for automation of a sliding gate
with 24 Vdc motor
Control unit
Power supply
No. of motors
Motor power supply
Flashlight
Warning light
Safety device power supply
Radio-receiver
Operating temperature
Pause time
Run time
Recommended battery type
Accessory power supply
Type