Technical Data
Specifications
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
Minimum activation flow is 0.4 GPM (1.5 L/min).
Our products are continually being updated and improved; therefore, specifications are subject to change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose
of input adjustment.
UGT
-
180
UGT
-
199
Minimum Gas Consumption Btu/h
10,300
Maximum Gas Consumption Btu/h
180,000
199,000
Hot water capacity (Min - Max) *
0.26 - 7.5 GPM
(1.0 - 28.5 L/min)
0.26 - 9.8 GPM
(1.0 - 37.0 L/min)
Temperature Setting (no controller)
120° F (49° C) or 140° F (60° C)
Maximum Temp Setting (residential)
Selectable at 120° F (49° C) or at 140° F (60° C)
Maximum Temp Setting (MCC-91 controller)
160° F (71° C)
185° F (85° C)
Minimum Temperature Setting
98° F (37° C)
Weight
45.6 lb (20.7 kg)
46.3 lb (21.0 kg)
Energy Factor
0.82
Noise level
49 dB (excluding start up or shutdown)
Electrical Data
Normal
76 W
97 W
Standby
2 W
Anti-frost Protection
120 W
Max Current
Without recirculation pump: 4 A
With recirculation pump: 8 A (exact value depends on the pump)
Fuse
10 A
By-Pass Control
Fixed
Electronic
Gas Supply Pressure
Natural Gas
4.0 - 10.5 inch W.C.
Propane
8.0 - 13.5 inch W.C.
Type of Appliance
Direct Vent, Tankless, Temperature controlled continuous flow gas hot water system
Connections
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Ignition System
Direct Electronic Ignition
Electric Connections
Appliance: AC 120 Volts, 60Hz.
Temperature Controller: DC 12 Volts (Digital)
Water Temperature Control
Simulation Feedforward and Feedback
Water Supply Pressure
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
Maximum Water Supply Pressure
150 PSI
Temperature Control Cable
Non-Polarized Two Core Cable (Minimum 22 AWG)
Energy Star Qualified
Yes
Certified for installation in manufactured
(mobile) homes
Yes
Complies with South Coast Air Quality
Management District 14 ng/J or 20 ppm NOx
emission levels
Yes
No