background image

22

ST

ANDARD 

BASIC 

LIMITED 

W

ARRANTY

ON 

RESIDENTIAL

 GAS 

W

A

TER 

HEA

TERS

GENERAL

The 

manufacturer 

warrants 

that, 

subject 

to 

verification 

of 

warranty

claim 

within 

the 

warranty 

period 

as 

described 

below

it 

will 

take 

the

necessary 

corrective 

action 

to 

either 

repair 

or 

replace 

water 

heater

or 

component 

part 

which 

is 

determined 

to 

be 

defective 

in 

material 

or

workmanship 

subject 

to 

the 

terms 

and 

conditions 

outlined 

in 

this

document. 

Further

, any 

replacement 

water 

heater 

or 

component 

part

supplied 

under 

warranty 

will 

carry 

only 

the 

unexpired 

portion 

of 

the

original 

water 

heater

’s 

warranty

The 

number 

of 

replacement 

water

heaters 

is 

limited 

to 

one 

(1) 

per 

original 

unit 

purchased. 

If 

due 

to

some 

extremely 

unusual 

circumstance, 

replacement 

water 

heater

or 

component 

part 

is 

found 

by 

our 

inspection 

testing 

department 

to

be 

defective, 

another 

heater 

or 

component 

part 

will 

be 

supplied 

to

fulfill 

the 

obligation 

of 

the 

warranty 

of 

the 

original 

heater

.

THE 

INNER 

TANK

If 

the 

inner 

tank 

fails 

within 

*SIX 

(6) 

years 

after 

the 

date 

of 

the 

origi-

nal 

installation, 

replacement 

water 

heater 

will 

be 

provided 

to 

the

party 

from 

whom 

the 

unit 

was 

originally 

purchased. 

If 

the 

water

heater 

is 

installed 

in 

other 

than 

single 

family 

dwelling, 

the 

tank 

war-

ranty 

is 

limited 

to 

ONE 

(1) 

year

If 

an 

exact 

replacement 

is 

not 

avail-

able, 

the 

manufacturer 

reserves 

the 

right 

to 

furnish 

comparable

model 

water 

heater; 

however

surcharge 

will 

be 

applied 

for 

any

additional 

component(s) 

incorporated 

in 

the 

replacement 

water

heater

. The 

warranty 

reply 

card 

must 

be 

completed 

and 

sent 

back 

to

the 

manufacturer 

within 

forty-five 

(45) 

days 

of 

the 

installation 

date. 

If

said 

warranty 

card 

is 

not 

returned, 

the 

date 

indicated 

on 

the 

model

serial 

plate 

will 

prevail. 

COMPONENT 

P

ARTS

If 

any 

component 

part 

is 

found 

to 

be 

defective 

within 

ONE 

(1) 

year

from 

the 

date 

of 

original 

installation, 

provided 

said 

defective 

part 

is

an 

in-house 

factory 

made 

piece 

or 

an 

original 

factory 

approved 

OEM

piece, 

the 

manufacturer 

will 

furnish 

replacement 

part 

after 

the

receipt 

and 

testing 

of 

the 

part 

claimed 

to 

be 

defective. 

THIS 

W

ARRANTY

 WILL

 NOT 

APPL

Y

1)

To 

defects 

or 

malfunctions 

resulting 

from 

failure 

to 

properly

install, 

operate, 

or 

maintain 

the 

unit 

in 

accordance 

with 

the 

print-

ed 

instructions.

2)

If 

the 

installation 

does 

not 

conform 

to 

CSA

 &/or 

ETL

 Standards

as 

well 

as 

any 

applicable 

national 

or 

local 

building 

codes.

3)

To 

any 

damage 

or 

failure 

caused 

by 

abuse, 

accident, 

fire, 

floods,

freezing, 

or 

other 

acts 

of 

God.

4)

To 

any 

damage 

or 

failure 

caused 

by 

operating 

the 

heater 

without

an 

approved 

pressure 

temperature 

relief 

valve 

having 

been

installed.

5)

To 

any 

damage 

or 

failure 

caused 

by 

operating 

the 

heater 

with 

an

empty 

or 

partially 

empty 

inner 

tank 

or 

sediment 

build-up 

result-

ing 

in 

dry 

firing 

of 

the 

heating 

elements.

6)

To 

any 

damage 

or 

failure 

caused 

by 

utilizing 

the 

heater 

in 

con-

junction 

with 

any 

other 

energy 

saving 

device 

or 

other 

source(s)

of 

energy 

not 

approved 

by 

the 

manufacturer; 

or 

for 

other 

than

use 

with 

potable 

water 

without 

any 

additives 

such 

as 

salt, 

chlo-

rine, 

or 

chemicals 

other 

than 

those 

added 

for 

the 

purpose 

of 

ren-

dering 

the 

water 

fit 

to 

drink.

7)

To 

any 

damage 

or 

failure 

caused 

by 

the 

removal 

of 

the 

anode

&/or 

by 

not 

assuring 

that 

there 

is 

working 

anode 

in 

the 

tank 

at

all 

times. 

All 

anodes 

must 

be 

checked 

at 

least 

once 

every 

two

years 

replaced 

if 

necessary

8)

To 

any 

damages 

or 

failure 

caused 

by 

having 

af

fixed 

to 

the 

heater

any 

non-factory 

made 

or 

factory 

approved 

replacement 

part(s)

such 

as 

elements, 

controls, 

dip-tubes, 

relief 

valves, 

etc...

9)

To 

any 

damage 

caused 

by 

not 

having 

the 

water 

heater 

installed

adjacent 

to 

free 

flowing 

drain 

in 

the 

event 

of 

water 

leakage. 

10)

If 

the 

heater 

is 

operated 

at 

water 

temperatures 

exceeding 

the

maximum 

setting 

of 

the 

operating 

&/or 

high 

limit 

control 

or 

the

heater 

is 

not 

supplied 

with 

potable 

water

free 

to 

circulate 

at 

all

times.

11)

If 

the 

heater 

has 

experienced 

the 

ef

fect 

of 

thermal 

expansion

due 

to 

excessive 

pressure 

(exceeding 

300PSI). 

The 

result 

of

excessive 

pressure 

usually 

reverses 

the 

bottom 

of 

the 

inner 

tank

and 

can 

occur 

with 

the 

addition 

of 

pressure 

reducing 

valve 

&/or

check 

valve 

in 

the 

municipal 

water 

supply 

system 

in 

single

family 

dwelling.

12)

If 

the 

heater 

is 

installed 

outside 

of 

Canada 

or 

the 

United 

States.

SER

VICE 

LABOUR 

RESPONSIBILITY

This 

warranty 

does 

not 

cover 

any 

labour 

expense 

for 

service,

removal, 

or 

re-installation 

of 

replacement 

heater

. All 

such 

expens-

es 

are 

your 

responsibility

.

SHIPPING 

COSTS

If 

water 

heater 

or 

component 

part 

is 

deemed 

to 

be 

replaced, 

the

manufacturer 

will 

pay 

the 

transportation 

costs 

of 

the 

replacement

unit 

to 

convenient 

authorized 

distributor 

or 

retailer 

as 

selected 

by

us. 

Y

ou 

must 

pay 

any 

local 

cartage 

including 

the 

cost 

of 

returning 

the

replaced 

item 

to 

the 

authorized 

distributor 

or 

retailer 

from 

whom 

the

replacement 

is 

coming 

from.

HOW 

T

MAKE 

A

 CLAIM

Any 

claim 

for 

warranty 

service 

should 

be 

made 

to 

your 

contractor

,

wholesaler

or 

retailer 

from 

whom 

the 

water 

heater 

was 

purchased.

In 

turn, 

said 

contractor

wholesaler

or 

retailer 

will 

contact 

the 

manu-

facturer 

from 

whom 

they 

purchased 

the 

heater

. If 

this 

procedure 

can-

not 

be 

followed, 

contact 

any 

other 

local 

contractor

wholesaler

or

retailer 

handling 

our 

water 

heaters. 

Also, 

for 

warranty 

information

you 

may 

call 

the 

manufacturer

’s 

customer 

service 

department 

at

(514) 

645-8893 

or 

1-800-363-9354, 

option 

1. 

W

suggest 

that 

prior

to 

calling 

the 

factory

that 

you 

make 

sure 

to 

have 

the 

model 

number

serial 

number 

that 

is 

to 

be 

found 

on 

the 

outside 

casing 

of 

the

heater

Proof 

of 

purchase 

showing 

the 

date, 

name, 

and 

place 

of 

the

business 

from 

whom 

the 

water 

heater 

was 

purchased 

is 

essential 

to

settle 

any 

warranty 

claim 

dispute 

over 

the 

length 

of 

the 

period 

of

installation.

If 

an 

exact 

replacement 

is 

not 

available, 

current 

model 

water

heater 

or 

component 

part 

with 

comparable 

operating 

features 

will 

be

provided 

by 

the 

manufacturer

If 

government 

regulations 

or 

industry

standards 

require 

the 

replacement 

model 

water 

heater 

or 

compo-

nent 

part 

to 

have 

features 

not 

found 

on 

the 

defective 

model 

water

heater 

or 

component 

part, 

you 

will 

be 

charged 

the 

dif

ference 

in 

price

associated 

with 

these 

required 

features. 

If 

you 

pay 

the 

dif

ference 

in

price 

for 

these 

required 

features, 

you 

will 

receive 

complete 

new

Standard 

Basic 

Limited 

W

arranty 

for 

the 

replacement 

water 

heater

.

MISCELLANEOUS

No 

one 

is 

authorized 

to 

make 

any 

other 

warranties 

on 

the 

manufac-

turer

’s 

behalf. 

Any 

implied 

warranties 

of 

any 

nature 

of

fered 

by 

third

party 

other 

than 

what 

is 

stated 

in 

this 

Standard 

Basic 

Limited

W

arranty 

will 

not 

be 

honoured. 

No 

claims 

for 

incidental 

or 

conse-

quential 

damages 

(including 

damages 

from 

leakage) 

will 

be 

accept-

ed. 

 If 

you 

do 

not 

return 

the 

warranty 

card, 

proof 

of 

purchase 

show-

ing 

the 

name, 

date, 

and 

location 

of 

the 

original 

source 

of 

purchase

is 

necessity 

to 

process 

warranty 

claim. 

Failure 

to 

produce 

this

documentation 

will 

result 

in 

the 

lesser 

or 

the 

warranty 

periods 

being

of

fered. 

In 

order 

to 

avoid 

any 

confusion 

&/or 

disputes, 

we 

suggest

that 

the 

warranty 

card 

be 

completed 

and 

mailed 

back 

no 

later 

than

forty-five 

(45) 

days 

after 

installation.

EXTENDED 

W

ARRANTIES

For 

information 

on 

some 

premium 

quality 

residential 

gas 

electric

water 

heaters, 

contact 

your 

local 

licensed 

plumber

or 

look 

for 

them

at 

selected 

retailers.

Содержание RESIDENTIAL DIRECT VENT GAS-FIRED WATER HEATERS

Страница 1: ... explosion may result causing property damage personal injury or death DO NOT store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your building From a neighbour s phone immediately call your gas supplier Follow the gas supp...

Страница 2: ...ts 18 Troubleshooting Guide 19 Warranty 22 This water heater meets the FVIR requirements in the standard for water heater It is equiped with a sealed combustion chamber and air intake system so it will not use any surounding air for combustion it will use combustion air from outside the building where the vent terminal is located thus it will prevent combustuble vapours from igniting outsite the w...

Страница 3: ...heater Many safety related messages have been provided in this manual and on your water heater Always read and obey all safety messages These messages will point out the potential hazard tell you how to reduce the risk of injury and tell you what will happen if the instructions are not followed This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you an...

Страница 4: ...Installation Code in Canada and or the National Fuel Gas Code ANSI Z223 1 NFPA54 in the United States Never operate the water heater unless it is properly ventilated to the outdoors and has adequate air supply for proper operation Failure to properly install the venting system could result in property damage personal injury or death This water heater is a direct vent gas water heater that draws al...

Страница 5: ...ns detail the installation of the co axial flexible vent pipe kit supplied with every water heater 1 Place the water heater in it s final position refer to the Location and Minimum Clearances sections for correct positioning requirements and verify if you are able to install the vent kit in accordance with the specifications illustrated in Figure 3 Note a The vent kit of this water heater can be i...

Страница 6: ...cm 3 feet 0 91 m F Clearance to each side of center line extended above 3 feet 91 cm within a 3 feet 91 cm within a m 7 5 4 t e e f 5 1 t h g i e h m 7 5 4 t e e f 5 1 t h g i e h y l b m e s s a r o t a l u g e r r e t e m above the meter regulator above the meter regulator assembly assembly G Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other applia...

Страница 7: ... the free reducer Insert the 6 inch 15 2 cm end of the reducer into the end of the flexible pipe that does not already have a reducer installed and secure them together with a six 6 inch 15 2 cm hose clamp Pull the 3 inch 7 6 cm flexible pipe over the 3 inch 7 6 cm pipe of the termination kit Secure them together with a three 3 inch 7 6 cm hose clamp Insert the 5 inch 12 7 cm end of the free reduc...

Страница 8: ...ert the five 5 inch 12 7 cm end of the reducer over the five 5 inch 7 6 cm air boot extrusion Secure them together with three 3 1 2 thread cut ting screws see Figure 7 7 Use metal hangers to keep the horizontal runs of flexible pipe with a minimum rise of 1 4 inch foot 21 mm m from the water heater to the termination kit see Figure 8 When the installation is complete visually inspect the venting s...

Страница 9: ...r Supply Systems CSA 4 4 in Canada and ANSI Z21 22 in the United States This relief valve has a maximum set pressure that does not exceed the hydrostatic working pressure of the water heater 150 psi 1 035 kPa and a BTU h rating equal to or greater than the input rating as shown on the water heater rating plate It should never be plugged or removed from the opening marked for it on the water heater...

Страница 10: ...If the relief valve discharges water on a continual basis it may indicate a malfunction of the relief valve and a qualified service technician must be called to have the system checked and the problem corrected Filling the Water Heater NEVER operate the water heater unless it is completely filled with water Failure to follow this instruction can result in premature failure of the water heater that...

Страница 11: ...taken at test pressures in excess of 1 2 psi 3 5 kPa the water heater and its gas supply manual shut off valve must be disconnected from the gas supply piping system and the end of the pipe sealed with a female cap If the testing is to be undertaken at a test pressure less than 1 2 psi 3 5 kPa the gas supply manual shut off valve must be closed A high altitude orifice MUST BE installed for water h...

Страница 12: ...eating and potable water supply and that the application will meet all local codes and public utility requirements Note It is good practice to oversize the water heater to ensure that all of the potential hot water require ments are available Check valve Cold to water heater Air handler Water heater Hot to house Circulation Pump Outlet to the space heating circuit Inlet from the space heating circ...

Страница 13: ...n installed with a minimum rise of 1 4 inch per foot 21 mm m of run L Have all of the vent air intake joints been sealed with high temperature silicone sealant L Has the venting been supported at the proper intervals with metal hangers L Water Piping Is the dip tube installed in the cold water inlet L Has a temperature and pressure relief valve been installed L Does this valve have a discharge lin...

Страница 14: ...staller service agency or the gas supplier DO NOT light this water heater if It is not full of water The gas supplied does not match the type listed on the rating plate The sight glass or burner access door gasket has been damaged or broken Gasoline or other flammable vapours and liquids have been stored in the vicinity of the water heater Failure to follow these instructions can result in propert...

Страница 15: ...g is created Stacking is the result of increased cycling of the burner and can produce very hot water temperatures at the hot water outlet Always remember to check the hot water coming out of any faucet with your hand before use This will reduce the risk of scalding related injury The gas control valve is equipped with an energy cut off E C O Should the temperature of the water exceed 194 F 90 C t...

Страница 16: ...move the inner access door at any time If the combustion chamber must be accessed to clean the burner assembly a quali fied service technician must be called Failure to follow these instructions can result in property damage personal injury or death Water Heater Tank Drain a pail of water through the drain valve at least once a year This will remove excess sediment from the bottom of the tank This...

Страница 17: ...the water heater drain valve and put the other next to a free flowing drain 6 Open the drain valve by inserting a flat head screwdriver into the slot on the head of the drain valve and turning the knob counterclockwise 7 Open a hot water faucet to allow air into the system Vacation If you are planning a vacation or other prolonged absence it is highly recommended to shut off the gas supply and the...

Страница 18: ... assembly 4 Burner assembly 5 Inner access door kit 6 Outer access door 7 Brass dain valve 8 Overflow tube 9 Dip tube 10 Magnesium anode rod 11 Temperature pressure relief valve 12 Outlet nipple 13 Flue baffle 14 Flue reducer 15 Complete vent kit 16 Flexible vent pipe 17 Wind tamer exterior vent cap REPLACEMENT PARTS ...

Страница 19: ... not blocked Orifice too large Replace with correct orifice Defective gas control valve Replace with new gas control valve The flame burns at Low gas pressure Check with gas utility company the orifice Defective gas control valve Replace with new gas control valve The pilot will not light No gas Check with gas utility company or remain lit Dirt in gas line Notify utility Install dirt leg in gas li...

Страница 20: ...erature Improper calibration Replace gas control valve Flue clogged Clean Check for source of trouble and correct Water heater is undersized Install size of water heater that meets demand Wrong piping connection Correct piping dip tube must be in cold inlet Wasted hot water Advise consumer Leaking water Poorly sealed hot or cold water connections Tighten threaded connections gas control valve thre...

Страница 21: ...ke terminal is not blocked Flue clogged Clean Check for source of trouble and correct Smoking and carbon Insufficient secondary air Check that the vent air intake terminal is not blocked formation sooting Low gas pressure Check with gas utility company Burner flame yellow lazy Refer to The burner flame is yellow and lazy Flue clogged Clean Check for source of trouble and correct Defective gas cont...

Страница 22: ...mage caused by not having the water heater installed adjacent to a free flowing drain in the event of water leakage 10 If the heater is operated at water temperatures exceeding the maximum setting of the operating or high limit control or the heater is not supplied with potable water free to circulate at all times 11 If the heater has experienced the effect of thermal expansion due to excessive pr...