 GS705N-30 Shear Lock Installation Instruction

 

Specifications 

 

 Connecting Diagram

Caution:

Make sure that the "+" and "-" 
wires are connected correctly. 
Failure to observe polarity will 
result  in  a  short  circuit  and  is 
n o t   c o v e r e d   b y   p r o d u c t  
warranty.

  Dimensions

 
 

Unit: mm

3

0

3

0

3

2

6

25

1

26

7

Push-off button

Armature vertical 
adjustment screws

Lock Bolt

Keep Hole

Keep Hole

Magnet Assembly

Armature Assembly

GS705N-30

Lock Bolt

+

-

Power

supply

Magnet bond sensor output
 SPDT rated: 
0.5A/125VAC, 1A/24VDC

+

-

N.O.

COM.

N.C.

P

o

w

e

In

p

u

t

M

a

g

n

e

b

o

n

d

 

s

e

n

s

o

o

u

tp

u

t

Vo l t a g e  S e l e c t i o n  j u m p e r s 
Check  jumper  settings  before 
connecting the lock to 24 VDC 
input  power.  Damage  to  the 
lock  may  result  from  incorrect 
jumper settings.

 

12Vdc

24Vdc

Holding Force                           

Power Input

Door Gap

Operating Temper.

Current Draw

Monitoring Output
             

Finish

Up to 1200 lbs (545 Kg) in shear.

12/24  VDC  selectable  via  jumpers  +10% 
over  voltage  is  acceptable  ,  under  voltage 
will reduce holding force.

420mA/12  VDC;  210mA/24  VDC    The  unit 
does not require initial voltage increase to 
operate.

M a g n e t  a n d  A r m a t u r e :  Z i n c  p l a t e d
Housing: Black powder coated

  SPDT  rating 

0.5A/125VAC, 1A/24VDC

2mm 

-30°C to +50°C

Magnet  bond  sensor  output, 

    Make sure that the door and frame is wide and deep enough to install the shear lock and run the wires. Make sure the central lines 
on the door frame and door leaf align. Install the magnet assembly in the door frame before installing the armature assembly in the 
door leaf.
Before  installation,  make  sure  the  door,  especially  double-action  doors,  always  return  to  the  dead  center  after  it  is  opened.  Use 
door hinges if necessary.

Control Device
N.C. contact or Access Relay

        Install  the  magnet  assembly  into  the  door 
frame  before  installation  the  armature  assembly 
into the door leaf. The magnet assembly requires 
space  to  run  wires,  as  wall  as  space  for  the 
recesses  portion  of  the  unit.  Make  sure  that  the 
position selected for the magnet assembly leaves 
enough  room  on  the  door  to  install  the  armature 
assembly. 