background image

www.hafele.com

Model PP8100

Digital door lock

* The contents of this user manual are subject to change without prior notice 
   to the user in order to enhance performance of the products.

PP8100

User manual

Содержание PP8100

Страница 1: ...www hafele com Model PP8100 Digital door lock The contents of this user manual are subject to change without prior notice to the user in order to enhance performance of the products PP8100 User manual ...

Страница 2: ... button 14 Replace batteries 14 Network module 14 How to change master PIN code 5 How to add user PIN code 5 How to add fingerprint 5 How to add key card 6 How to delete user PIN code 6 How to delete fingerprint 7 How to delete key card 7 Opening mode setting 8 Voice guide setting 8 Language setting 8 System query serial number 8 Network module Optionally available 9 Bluetooth setting 9 Defense mo...

Страница 3: ...is suspended with alarm When the double lock function is activated the door cannot be opened from outside with user PIN code key card or fingerprint except with master PIN code Privacy function Random security coding function The random number can be added before or after the real user PIN code but the maximum length is 32 digits This feature will prevent the real user PIN code from being exposed ...

Страница 4: ...re is a low battery alert please replace all the batteries in time and make sure they are properly installed 1 You can follow the voice guide by multi language English Chinese 2 Master PIN code 6 12 digits Default master PIN code is 12345678 please modify it after installation 3 User PIN code 6 12 digits Maximum capacity is 10 with user number 00 09 4 Fingerprint Maximum capacity is 100 with user ...

Страница 5: ...ser PIN code Input number 00 99 Input number 00 09 Enter card Touch the screen to activate lock Settings Master PIN code Opening mode setting Important First step is to set your own master PIN code Speaker Wrong code entry limit Shutdown time Voice guide language Factory defaults 12345678 Normal mode Enabled 5 times 2 mins English ...

Страница 6: ...me you can return to the previous menu by pressing the key How to add fingerprints 1 When registering user fingerprint the fingerprint must be entered within 10 seconds 2 At any time you can return to the previous menu by pressing the key User Number User Type Notes 00 04 Normal User Permanent 05 08 Temporary User Invalid after using one time or in safety mode 09 Reserved Only used in combination ...

Страница 7: ... time you can return to the previous menu by pressing the key Delete access data How to delete user PIN code Delete one user PIN code 6 12 digits Delete all user PIN code Unusable in safe mode 6 12 digits 1 When deleting user PIN codes the user number must be entered within 10 seconds 2 At any time you can return to the previous menu by pressing the key ...

Страница 8: ...card 1 When deleting user card the card or user number must be entered within 10 seconds 2 At any time you can return to the previous menu by pressing the key 6 12 digits 6 12 digits 6 12 digits 6 12 digits Fingerprint to be deleted or Key card to be deleted or 1 When deleting user fingerprint the fingerprint or user number must be entered within 10 seconds 2 At any time you can return to the prev...

Страница 9: ... serial number Turn off voice guide Excluding alarm and menu operation Additional lock features 6 12 digits Chinese English Normal mode Single verification means opening by PIN code fingerprint or card Safe mode Double verification means opening by PIN code fingerprint PIN code card or fingerprint card or Opening mode setting Turn on voice guide ...

Страница 10: ... door is opened properly from outside the defense mode will be disabled Network module Optionally available Log off network 6 12 digits 6 12 digits Join network Bluetooth settings Manage Bluetooth under Bluetooth turned on Enable Bluetooth 6 12 digits 6 12 digits or or Connect Bluetooth Disconnect Bluetooth Disable Bluetooth 1 The default setting for Bluetooth is disabled 2 Please enabling the Blu...

Страница 11: ...itch to display green mark The indoor handle can be pushed or pulled freely Auto Manual mode 1 Remove battery cover to find the A M switch 2 A means auto mode when door is closed the deadbolt will drive out automatically the door will be in locked status 3 M means manual mode when door is closed the deadbolt will not drive out then the door will be in unlocked status 2 In manual mode when the door...

Страница 12: ...s voice mode will be disabled automatically 1 User setting 2 System setting 3 System query 4 Function extension 5 Bluetooth setting Press 1 1 Enroll user PIN code 2 Enroll fingerprint 3 Enroll card 4 Delete user PIN code 5 Delete fingerprint 6 Delete card 7 Opening mode Setting 9 Change master PIN code 1 Voice guide setting 2 Language setting 1 System query serial number 1 Join network 2 Log off n...

Страница 13: ...ull handle to open the door 1 Place the enrolled card properly on the card icon area until one beep sounds Voice prompt Verification Succeeded 2 Push or Pull handle to open the door Insert the key into key hole and rotate it with proper angles Then push or pull handle to open the door Random security coding function The random number can be added before or after the real user PIN code but the maxi...

Страница 14: ... door Auto locking In auto mode door will be locked automatically in 1 5 seconds after closing Manual locking In manual mode press CLOSE button to lock the door from inside or verify user fingerprint PIN code card to lock the door from outside Restore to factory default settings Reset button Operation instructions 1 Open the upper cover and find the reset button 2 Double click RES button then voic...

Страница 15: ...oups One group works for power supply two groups is used for longer operation time Do not mix old and new batteries together in replacement Network module Please contact Hafele customer service center for more details Access master mode and press 4 for function extension which is reserved for wireless communication and other smart home interfaces Network module interface Network module optionally ...

Отзывы: