Power 

UPS

Control

Device

Electromagnetic Locks

Power 

Input

Reed

2-2

  

Important Note

Problem                                           Possible Cause                                                                        Solution

Door does not lock

No power

Poor contact between electromagnet and 
armature plate

Low voltage or incorrect voltage setting

A secondary diode was installed across 

the electromagnetic lock

Misalignment between the armature

 

plate

and electromagnetic lock

Make sure the wires are connected properly

Check that the power supply is connected and works properly

Make sure the lock switch is wired correctly

Make sure the armature plate is not deformed

Make sure the contact surfaces of the electromagnet and armature plate are clean 

and free from dust and foreign material.

Make sure the armature plate and electromagnetic lock are aligned correctly

Make sure the rubber washer was used between the bracket and armature plate

Check the electromagnetic lock is set for the correct voltage.

Check the voltage at the electromagnetic lock input. If low, determine if the 

correct wire gauge is being used to prevent excessive voltage drop.

Remove any diode installed across the magnet for "spike" 

suppression. (The magnet is  fitted with a metal oxide varistor to prevent back EMF)

Low holding force

Sensor output is not functioning

 

Trouble Shooting

 

Connecting Diagram

The electromagnetic lock requires a face-to-
face  alignment  as  shown  in  the  Figure. 
O t h e r w i s e ,  t h e  h o l d i n g  f o r c e  w i l l  b e 
decreased to 25%.

Make sure the contact area of the 
electromagnetic  lock  and  the 
armature  plate  is  correct  or  the 
bond sensor output function will 
not work.

Wipe the surface of magnet lock
with anti-rust oil regularly.

+

-

N.O.

COM.

N.C.

Power 

Input

S

e

n

s

o

O

u

tp

u

t

Do not run power wires and signal 
wires in the same cable or conduit.

Remove  any  diode  installed
across  the  magnetic  lock  for
spike suppression. The magnet
is  built-in  with  a  metal  oxide
varistor to prevent back EMF.

 

 

 

 

 

 

 

 

Bond sensor output

N.C. contact output: open status
N.O. contact output: locked status
SPDT relay rated: 0.5A/125VAC
                               1A/24VDC
Models: 10000R , 10000STR 

(Polarity Free)

+

-

Power

supply

Control Device

N.C. contact or Access Relay

 

12VDC

24VDC

Voltage Selection jumpers
Check  jumper  settings  before 
connecting  the  lock  to  24  VDC 
input power. Damage to the lock 
may result from incorrect jumper 
settings.

 

Butt Splice(IDC) Connector 

Use crimper or pliers and press the header  
of connector down to even position

Dual Voltage Models:
10000,10000R,10000STR

Make  sure  the  contact  surfaces 
o f  t h e  e l e c t r o m a g n e t  a n d 
armature plate are clean and free 
from dust and foreign materials.

The  electromagnetic  locks  are
fail  safe.  Therefore  it  needs  the 
p o w e r  f r o m  U P S  t o  r e m a i n
locked during the power  failure.

Copyright © Gianni Industries, Inc. All rights reserved. 
P-MU-03M  Ver. L   Published on: 2012.03.20                                                        