background image

Copyright    All Rights Reserved.  P-MU-ML-400   Published: 2021.11.29

5-1

5-2

5-3

5-4

5-5

Surface Mount Model Dimensions

ø5.2mm

25

ø5.2mm

23.5

210

28

ø5.2mm

210

23.5

ø5.2mm

Mortise Mount Installation

Unti:mm

210

25

23.5

210

23.5

28

ø5.2mm

ø5.2mm

ø5.2mm

ø5.2mm

Do

or l

eaf

Do

or 

Fra

me

Attention! Please ensure that the
template is the correct way up. 

Alignment CL

Align the center line (CL) of the lock 

body template with the CL of the door 
leaf. Ensure the CL of the strike plate 

template matches the lock body CL as 

closely as possible.

Cut out mortise holes for the lock 

body and strike plate and drill  

holes according to the templates.

Tighten the fixing lugs with

screws.

Connect power cable to the lock

and test before screwing to the 

door leaf.

Affix the strike plate.

Unti:mm

ML-400MSMB

32.5

200

50

180

Doo

r Le

af

Fra

me

Door

 Lea

f

Doo

r Le

af

Doo

r Le

af

Fra

me

Door Loop

(Optional)

The door loop protects the wiring 

from damage at the door hinge.

32.5

200

50

180

4-2

Содержание ML-400M

Страница 1: ... strength Mortise Mount Model Dimensions Unti mm ML 400 Series Models ML 400M Mortise mount ML 400MSMB Surface mount ML 400MVGL Surface mount Installation Instruction for frameless glass doors walls Wiring Diagram Door Status Output 12 24VDC AC 1A 125VAC Red Black Blue N O Green COM Yellow N C Using crimper or pliers and pressing the header of connector down to even position Butt Splice IDC Connec...

Страница 2: ...ter line CL of the lock bodytemplatewiththeCLofthedoor leaf Ensure the CLof the strike plate templatematchesthelockbodyCLas closely as possible Cut out mortise holes for the lock body and strike plate and drill holes according to the templates Tighten the fixing lugs with screws Connect power cable to the lock and test before screwing to the door leaf Affix the strike plate Unti mm ML 400MSMB 32 5...

Страница 3: ...ed P MU ML 400 Published 2021 11 29 Surface Mount Installation Glass Mount Model Dimensions 53 5 56 212 56 53 5 212 Unti mm M6 x 25 Screw M6 x 25 Screw ML 400MVGL Door Leaf Door Freme Blind Nut Blind Nut Interior Secured Side 4 3 ...

Страница 4: ...hickness should be 10 13 mm The bracket can be adjusted to properly align the position of strike plate and lock body depending on the door gap ranging from 6 to 10 mm 1 Confirm the installation location and clean the surface of the glasses 2 Take off the sticker on the back side of the spacer and attach the space to the glass Add more spacers if needed per glass thickness Use silicone sealant or o...

Отзывы: