background image

4 - 2

12VDC Power supply

12VDC Power supply

Wiring Diagram

ML-210 Voltage Input: 12 or 24VDC

Lock bolt sensor status output

For 12VDC operation, the solenoid input wires 

should be connected in parallel as shown.

Black

Red

Black

Red

Varistor

Access Control Device

N.C. contact

(Power input is polarity free)

Yellow

Green

Blue

“Fail-Safe”

(Power to Lock)

“Fail-Secure”

(Power to Open)

Yellow

Green

Blue

Access Control Device

N.O. contact

Varistor

Black

Red

Black

Red

(Power input is polarity free)

For 24VDC operation, the solenoid input wires
should be connected in series as shown.

12VDC Power supply

Black

Red

Black

Red

Varistor

(Power input is polarity free)

24VDC Power supply

“Fail-Safe”

(Power to Lock)

Yellow

Green

Blue

Copyright © All Rights Reserved.   P-MU-ML-210  Ver. C  Publish: 2010.12.02

Access Control Device

N.O. contact

Black

Red

Black

Red

Varistor

(Power input is polarity free)

24VDC Power supply

Yellow

Green

Blue

“Fail-Secure”

(Power to Open)

Access Control Device

N.O. contact

4 - 3

Wiring Diagram

ML-210-SW Voltage Input: 12~24VDC/AC

Lock bolt sensor status output

For the 12~24VDC/AC operation only

NOTE: 

The varistor (or diode) must be connected across the terminals as shown. This protects the electromechanical lock

from spikes and surges.

Copyright © All Rights Reserved.   P-MU-ML-210  Ver. C  Publish: 2010.12.02

12~24VDC/AC Power supply

“Fail-Safe”

(Power to Lock)

Red

Red

Varistor

(Power input is polarity free)

Yellow

Green

Blue

Access Control Device

N.O. contact

Red

Red

Varistor

12~24VDC/AC Power supply

(Power input is polarity free)

“Fail-Secure”

(Power to Open)

Yellow

Green

Blue

Access Control Device

N.O. contact