5.  Adding PINs to Relay 1 

a: 

1. Enter programming mode to select slot position 

001~

200 (rapid green LED 

flash to indicate the slot position is available) 

2. Enter new PIN (1 beep, green LED stay on) 

3. Press # (1 beep) back to programming mode 

4. Press # again (1 beep) back to standby mode (slow yellow LED flash) 

b: 

 

1. Enter programming mode to select slot position 

001~

200 (green LED stay 

on to indicate the slot position is unavailable) 

  2.  Press  00000  (1  beep)  delete  the  data  from  the  slot  position  (rapid  green  LED 

flash) 

3. Repeat the steps of

 

5-a

 

to add new PINs. 

6.  Adding PINs to Relay 2 

a: 

1.  Enter  programming  mode  to  select  slot  position 

201~

210  (rapid  red  LED 

flash to indicate the slot position is available) 

2. Enter new PIN (1 beep, red LED stay on) 

3. Press # (1 beep) back to programming mode 

4. Press # again (1 beep) back to standby mode (slow yellow LED flash) 

b: 
 

1. Enter programming mode to select slot position 

201~

210 (red LED stay on 

to indicate the slot position is unavailable) 

  2. Press 00000 (1 beep) delete the data from the slot position (rapid red LED flash) 

  3. Repeat the steps of

 

6-a

 

to add new PINs. 

 

7.  Change Master Code 

1. Enter programming mode. 

2. Press 

000 + XXXXX (5-digit master code), 1 beep, yellow LED stay on. 

3. Press # (1 beep) back to programming mode. 

4. Press # again (1 beep) back to standby mode, slow yellow LED flash. 

8.  Change PIN length 

1. Enter programming mode 
2. Press 

555 + 5~8-digit code, then press # to exit programming mode. 

 

 

Содержание DG-200

Страница 1: ... indicators buzzer for status indication Keypad with beep sound 5 Metal case stainless steel panel designed with mechanical key lock designed for easy wiring maintenance enhanced safety and durability 6 Weather resistance for outdoor applications 7 Additional input for anti tailgating function to ensure high security access control 8 Non volatile memory stores all code settings for a long time eve...

Страница 2: ...1 99 seconds Toggle mode 00 LED Status Indication 3 LED indicators display Red Yellow Green Ambient Humidity 5 95 Non condensing Operating Temperature 20 C 70 C III Status Indication Default Setting Parameters Mode Status Green First relay active Red Second relay active LED Yellow Normal Power On 1 Short Beep Key in 1 Long Beep Valid PINs 2 Beeps Enter exit programming mode 3 Beeps Incorrect input...

Страница 3: ...tting the Relay Strike Time The relay strike time determines the amount of time that the door remains unlocked after a valid PIN is entered NOTE Enter 00 will set the relay strike time to 0 second relay set to toggle mode 1 Enter programming mode 2 Press 300 for Relay 1 rapid green LED flash Enter 00 99 1 beep green LED stay on Press 400 for Relay 2 rapid red LED flash Enter 00 99 1 beep red LED s...

Страница 4: ...g PINs to Relay 2 a 1 Enter programming mode to select slot position 201 210 rapid red LED flash to indicate the slot position is available 2 Enter new PIN 1 beep red LED stay on 3 Press 1 beep back to programming mode 4 Press again 1 beep back to standby mode slow yellow LED flash b 1 Enter programming mode to select slot position 201 210 red LED stay on to indicate the slot position is unavailab...

Страница 5: ...inals to suppress the back EMF of the strike failure to do so will damage the relay contacts and electronic components or even burns the controller Warranty The product is warranted against defects in material and workmanship while used in normal service for a period of 1 year from the date of sale to the original customer The GEM policy is one of continual development and improvement therefore GE...

Отзывы: