P-MU-DG-200      Ver. A    Publish: 2009.11.30                                                                                                                        Page: - 1 -/ 5                                                                                                                                                                         

DG-200 Digital Keypad   

Operation Manual 

Unit: (mm) 

I. Features:

 

1. 

Allows up to 200+10 PINs.

 

2. 

29-digit-code password protected design.

 

3. 

Lockout for 60 seconds after entering 5 times invalid PINs (The keypad without 

beep sound during the period time).

 

4. 

3 LED indicators & buzzer for status indication. Keypad with beep sound.

 

5. 

Metal case & stainless steel panel designed with mechanical key lock designed 

for easy wiring & maintenance, enhanced safety and durability.

 

6. 

Weather

 

resistance for outdoor applications.

 

7. 

Additional input for anti-tailgating function to ensure high security access control.

 

8. 

Non-volatile memory stores all code settings for a long time, even in the event of 

total power failure.

 

9. 

Dual relays to control door lock and other security devices.

 

10. 

Built-in tamper switch.

 

Содержание DG-200

Страница 1: ... indicators buzzer for status indication Keypad with beep sound 5 Metal case stainless steel panel designed with mechanical key lock designed for easy wiring maintenance enhanced safety and durability 6 Weather resistance for outdoor applications 7 Additional input for anti tailgating function to ensure high security access control 8 Non volatile memory stores all code settings for a long time eve...

Страница 2: ...1 99 seconds Toggle mode 00 LED Status Indication 3 LED indicators display Red Yellow Green Ambient Humidity 5 95 Non condensing Operating Temperature 20 C 70 C III Status Indication Default Setting Parameters Mode Status Green First relay active Red Second relay active LED Yellow Normal Power On 1 Short Beep Key in 1 Long Beep Valid PINs 2 Beeps Enter exit programming mode 3 Beeps Incorrect input...

Страница 3: ...tting the Relay Strike Time The relay strike time determines the amount of time that the door remains unlocked after a valid PIN is entered NOTE Enter 00 will set the relay strike time to 0 second relay set to toggle mode 1 Enter programming mode 2 Press 300 for Relay 1 rapid green LED flash Enter 00 99 1 beep green LED stay on Press 400 for Relay 2 rapid red LED flash Enter 00 99 1 beep red LED s...

Страница 4: ...g PINs to Relay 2 a 1 Enter programming mode to select slot position 201 210 rapid red LED flash to indicate the slot position is available 2 Enter new PIN 1 beep red LED stay on 3 Press 1 beep back to programming mode 4 Press again 1 beep back to standby mode slow yellow LED flash b 1 Enter programming mode to select slot position 201 210 red LED stay on to indicate the slot position is unavailab...

Страница 5: ...inals to suppress the back EMF of the strike failure to do so will damage the relay contacts and electronic components or even burns the controller Warranty The product is warranted against defects in material and workmanship while used in normal service for a period of 1 year from the date of sale to the original customer The GEM policy is one of continual development and improvement therefore GE...

Отзывы: