1.0 INTRODUCTION
This booklet describes the operating procedures for ACB 531 series el/pump.
These pumps are usually used for marine application, to pump sea and fresh water, diesel oil, not
inflammables liquids and liquids without suspended parts.
Most common uses are: Bilge, Diesel and Oil Transfer, Fire-Fighting, plant supply or where
required a pump with a good flow rate.
Standard construction is with bronze body pump and impeller.
The use of these machines must be made by qualified and experienced personnel, in full
compliance with local legislation.
These instructions should be carefully read before installation of any ACB 531 series pump.
The manufacturer declines all responsibility in case of accident or damage due to
negligence or lack of observance of instructions given in this booklet, or application in
conditions not conforming to detail on the motor plate. All responsibility is also declined for
damage caused by improper use of the pump
1.1 CONDITION OF USE
These el/pumps must be used with clean liquids in this conditions:
-
Max pressure admitted in the pump casing
8 Bar
-
Max suction depth
8m
-
Temperature of the liquid from
-5°C to +60°C
-
Acustic level
<85 dB
-
Pump abrasive liquids
Not admitted
1.2 PRELIMINARY INSPECTION
Unpack the pump and check its integrity. Furthermore check that the data on the plate corresponds
to the data required and that the shaft turns freely. If there is any irregularity, contact the
GIANNESCHI Pumps and Blowers immediately, signalling the nature of the discrepancy.
CAUTION: If there is any doubt about safety of the pump, do not use it.
1.3 STORAGE INSTRUCTION
After receipt and inspection the unit, if not immediately installed, the unit must be repackaged and
stored in the best way.
For a proper storage proceed as follows:
-
Store the pump in a location witch is closed, clean, dry and free of vibrations.
-
Do not store in areas with less than 5°C temperature (for lower temperature
it’s
necessary to completely the drain the pump of any liquids which are subject to
freezing)
-
Fill the pump with a rust-preventative liquid that is compatible with the pump gaskets
and elastomers. Rotate the shaft by hand to impregnate all internal surface. Drain
the excessive liquid from the pump and months.
-
Cover the pump with plastic sheet or similar protective material.
-