39
3.5.1 Change SMBIOS Event Log Settings
SMBIOS Event Log
Change this item to enable or disable all features of the SMBIOS Event Logging during system
boot. The options are Enabled and Disabled.
Erase Event Log
If this feature is set to Yes, all logged events will be erased. The options are No, Yes, Next
reset and Yes, Every reset.
When Log is Full
Select Erase Immediately for all messages to be automatically erased from the event log
when the event log memory is full. The options are Do Nothing and Erase Immediately.
Log System Boot Event
This option toggles the System Boot Event logging to enabled or disabled. The options are
Disabled and Enabled.
MECI
The Multiple Event Count Increment (MECI) counter counts the number of
occurences. A duplicate event must happen before the MECI counter is incremented. This is a
numeric value. The default value is 1.
METW
Use the Multiple Event Time Window (METW) to define the length of time (in minute) it
must pass before a duplicate log event entry is generated. Enter a number from 0 to 99. The
default value is 60 (minutes).
Содержание N21M-MV