21
FT-M1211A
2.2 INSTALLATION
The floor must be level and capable of supporting the weight of the machine.
The machine must be put by level with regard to the ground
- Connect the compressed air to the main air supply, which must be equipped with a shut off
valve.
- Connect the electricity to the differential circuit breaker corresponding to the machine,
previously installed.
- Check that the voltage of the machine and the factory are compatible.
- Check the pressure for the compressed air.(6 bars recommended)
- Remove the links which maintain the flaps of the stacker.
2.3 CONNECTING TO THE ELECTRIC AND AIR SUPPLIES.
Connecting to the air supply:
The machine is equipped with a central compressed air system with a manometer, a reduc-
tion valve and an air filter.
The machine is equipped with an air treatment assembly:
Filter / Regulator / Lubricator (See chapter 5 Maintenance procedures).
The client is responsible to bring the air supply up to the shut off valve.
Additionally, this air must be dry and free of dust.
To supply the machine, it is necessary to use a hose with a minimum diameter of
1 5 / 2 1
(1/2 pouce).
The air supply must have a constant pressure of 6 bars minimum, in order to obtain, a
decent regulation and to avoid malfunctioning due to drops in pressure.
In the case where the air supply is below the suply point for the machine, foresee the
appropriate connectors.
NOTE : Not respecting these conditions will lead to the poor functioning of the
material.
Содержание FT-MAXI
Страница 2: ...Modele Series FT MAX I FromPLP243...
Страница 6: ...FT M1211A 6 CE DECLARATION OF CONFORMITY...
Страница 12: ...FT M1211A 12 IM03019 C...
Страница 13: ...13 FT M1211A IM03064 C...
Страница 14: ...FT M1211A 14 IM03065 C...
Страница 15: ...15 FT M1211A IM03066 C...
Страница 16: ...FT M1211A 16 IM03151 C...
Страница 17: ...17 FT M1211A IM03152 C...
Страница 18: ...FT M1211A 18 IM03153 C...
Страница 19: ...19 FT M1211A IM03154 C...
Страница 28: ...FT M1211A 28 Put the main switch into the OFF position Close the compressed air supply valve...
Страница 40: ...FT M 1211A 40...
Страница 41: ...41 FT M1211A 8 EXPLODED VIEWS...
Страница 42: ...FT M 1211A 42...
Страница 44: ...FT M 1211A 44...
Страница 46: ...FT M 1211A 46...
Страница 47: ...47 FT M1211A KIT 09 0031 PART 1 ID Ref Qty Description 1 14 0967 1 Distributor 2 14 0968 1 Silencer U 3 8 B...
Страница 48: ...FT M 1211A 48...
Страница 50: ...FT M 1211A 50...
Страница 52: ...FT M 1211A 52...
Страница 54: ...FT M 1211A 54...
Страница 56: ...FT M 1211A 56...
Страница 58: ...FT M 1211A 58...
Страница 60: ...FT M 1211A 60...
Страница 62: ...FT M 1211A 62...
Страница 64: ...FT M 1211A 64...
Страница 66: ...FT M 1211A 66...
Страница 68: ...FT M 1211A 68...
Страница 70: ...FT M 1211A 70...
Страница 72: ...FT M 1211A 72...
Страница 74: ...FT M 1211A 74 1 8 2 5 4 6 3 8...
Страница 76: ...FT M 1211A 76...
Страница 78: ...FT M 1211A 78 4 6 5...
Страница 80: ...FT M 1211A 80 1 3 4 2 5 1 14 0184...
Страница 82: ...FT M 1211A 82...
Страница 84: ...FT M 1211A 84...
Страница 86: ...FT M 1211A 86...
Страница 88: ...FT M 1211A 88...
Страница 90: ...FT M 1211A 90...
Страница 92: ...FT M 1211A 92...
Страница 94: ...FT M 1211A 94 1 2 3...
Страница 96: ...FT M 1211A 96...