background image

TROUBLESHOOTING  TIPS

Before calling for service, review the chart below first yourself.

Problem

What to check

Unit does not start

Make sure the dehumidifier s plug is pushed completely into the

outlet.

Check the house fuse/circuit breaker box.

Dehumidifier has reached its preset level or bucket is full.

Water bucket is not in the proper position.

Dehumidifier does not

dry the air as it should

Did not allow enough time to remove the moisture.

Make sure there are no curtains, blinds or furniture blocking the

front or back of the dehumidifier.

The humidity control may not be set low enough.

Check that all doors, windows and other openings are securely

closed.

O

O

Room temperature is too low, below 5 C(41 F).

There is a kerosene heater or something giving off water vapor

in the room.

,

The unit makes a loud

noise when operating

The air filter is clogged.

The unit is tilted instead of upright as it should be.

The floor surface is not level.

Frost appears on the 

coils

This is normal. The dehumidifier has Auto defrost feature.

Water on floor

Hose to connector or hose connection may be loose.

Intend to use the bucket to collect water, but the back 

drain plug is removed.

ES, AS,P2,EC ,Eb and 

E3 appear in the display

These are error codes and protection code. See the 

CONTROL 

PADS ON THE DEHUMIDIFIER

 section. 

10

The pump operation

on light blinks at 1Hz

Clean the filter of the pump.

Check the pump hose does not link or block.

Empty the water of the bucket.

3. Clean the air filter

Remove the filter every two weeks based on normal 

operating conditions.

To remove the filter, pull filter outwards (See Fig.14).

Wash the filter with clean water then dry.

Re-install the filter,replace Bucket.

CAUTION:

DO NOT operate the dehumidifier without a filter

because dirt and lint will clog it and reduce

performance.

After turning off the unit, wait one day before emptying 

the bucket.

Clean the main unit, water bucket and air filter.

Cover the unit with a plastic bag.

Store the unit upright in a dry, well-ventilated place.

 

Wrap the cord with the power cord buckle.

4. When not using the unit for long time periods

Care and cleaning of the dehumidifier

Turn the dehumidifier off and remove the plug 
from the wall outlet before cleaning.

1. Clean the Grille and Case

Use water and a mild detergent. Do not use bleach 

or abrasives.

Do not splash water directly onto the main unit. Doing

so may cause an electrical shock, cause the insulation

to deteriorate, or cause the unit to rust.

The air intake and outlet grilles get soiled easily, so use

a vacuum attachment or brush to clean.

2. Clean the bucket

Every few weeks, clean the bucket to prevent growth of mold,

mildew and bacteria. Partially fill the bucket with clean water 

and add a little mild detergent. Swish it around in the bucket,

empty and rinse.

NOTE:

 Do not use a dishwasher to clean the bucket.

After clean, the bucket must be in place and securely 

seated for the dehumidifier to operate.

Fig. 14

CARE  AND  MAINTENANCE

11

Содержание GIADB40X6PW

Страница 1: ...OWNER S MANUAL DEHUMIDIFIER X6WE GIADB40X6PW GIADB50X6PW ENGLSIH Thanks for choossing our product Please read carefully this manual before using the product...

Страница 2: ...user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the use...

Страница 3: ...ck of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play the applianc...

Страница 4: ...d Do not place the unit near a heat source Before cleaning turn off the power and unplug the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc CAUTION...

Страница 5: ...echnician Do not place flower vases or other water container on top of the unit The manufactures nameplate is located on the rear panel of the unit and contains electrical and other technical data spe...

Страница 6: ...e bucket is full the pump starts to work Refer to the next pages for removing the collected water Do not use this operation when the outdoor temperature O O is equel to or less than 0 C 32 F 2 COMFORT...

Страница 7: ...re The system starts to count the time once the fan motor operates The check filter feature can be only activated when the accumulated operation time achieves 250 hours or more The Reset light Clean f...

Страница 8: ...anation purposes only The actual shape of the unit you purchased may be slightly different but the operations and functions are the same Accessories placed in the water bucket of the unit pump drain h...

Страница 9: ...ater in the bucket The unit may tip over and spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there...

Страница 10: ...reinstall the pump hose properly to the unit before replace the bucket into the unit see Fig 8 When you remove the bucket if there is some water in the unit you must dry it When the unit is on if the...

Страница 11: ...wn to let the water flow smoothly Do never let it up Select the desired humidity setting and fan speed on the unit for pump draining to start Pump drain hose Pump drain hose outlet NOTE The pump opera...

Страница 12: ...and cleaning of the dehumidifier Turn the dehumidifier off and remove the plug from the wall outlet before cleaning 1 Clean the Grille and Case Use water and a mild detergent Do not use bleach or abr...

Страница 13: ...other openings are securely closed O O Room temperature is too low below 5 C 41 F There is a kerosene heater or something giving off water vapor in the room The unit makes a loud noise when operating...

Страница 14: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...

Отзывы: