background image

Removing the collected water

1. Pull out the bucket  a little.

2. Hold both sides of the bucket

    with even strength, and pull it 

    out from the unit.

There are three ways to remove collected water.

1. Use the bucket

    

When the unit is off,if the bucket is full, the Full indicator

     light will light.

     When the unit is on,if the bucket is full, the compressor

     and the fan turn off, and the Full indicator light will light, 

     the digital display shows P2.

     Slowly pull out the bucket. Grip the left and right 

     handles securely, and carefully pull out straight so 

     water does not spill. Do not put the bucket on the floor 

     because the bottom of the bucket is uneven. Otherwise 

     the bucket will fall and cause the water to spill.

     Throw away the water and replace the bucket. The 

     bucket must  be in right place and securely seated  for the 

     dehumidifier to operate.

     The machine will re-start when the bucket is restored

     in its correct position.

Fig.5

Fig.6

OPERATING  THE  UNIT

3. Pour the water out.

NOTES:

    When you remove the bucket, do not touch any parts 

     inside of the unit. Doing so may damage the product.

     Be sure to push the bucket gently all the way into the 

     unit. Banging the bucket against anything or failing to 

     push it in securely may cause the unit not to operate.

     If the pump hose drops when you remove the bucket 

     (see Fig.7),you must reinstall the pump hose properly 

     to the unit before replace the bucket into the unit 

     (see Fig.8).     

     When you remove the bucket,if there is some water in

     the unit you must dry it.

     When the unit is on, if the bucket is removed, the 

     compressor and the fan turn off, then the unit will beep

     8 times and the digital display shows Eb. 

     When the unit is off, if the bucket is removed, the unit 

     will beep 8 times and the digital display shows Eb.

2. Continuous draining

Water can be automatically emptied into a floor 

drain by attaching the unit with a water hose

(Id

   5/16 , not included) with a female threaded

end (ID:M=1  , not included)

NOTE: On some models, the female threaded

end is included

8

    

 

    Remove the plastic cover from the back drain outlet of 

    the unit and set aside, then insert the drain hose through 

    the drain outlet of the unit and lead the drain hose to

    the floor drain or a suitable drainage facility. (See.Fig.9

    and Fig.10)

    When you remove the plastic cover, if there is some 

    water in the back drain outlet of the unit you must dry it.

    Make sure the hose is secure so there are no leaks and

    the end of the hose is level or down to let the water flow

    smoothly.

    Direct the hose toward the drain,making sure that

    there are no kinks that will stop the warter flowing.

    

Fig.9

NOTE: When the continuous draining feature is not being used,remove the drain hose from the outlet,

and dry the water in the continuous drain hose outlet.

Fig.7

Fig.8

Pump hose

drops

Reinstall pump 

hose properly

Fig.10

Remove the

plastic cover

by couter-clockwise

rotation.

    

    

    Select the desired humidity setting and fan speed on the 

    unit for continuous draining to start.

Drain hose

Removing the collected water

3. Pump draining (on some models)

Water can be automatically emptied into a floor 

drain or a suitable drainage facility by attaching 

the pump drain out with a pump drain hose 

(   od=1/4  , supplied).

    Remove the continuous drain hose from the unit and install 

    the plastic cover to the continuous drain hose outlet of the 

    unit by clockwise rotation.(See Fig.11)  

    Resert the pump drain hose into the pump drain hose

    outlet for depth of 15mm at least (See Fig.11), then lead 

    the water hose to the floor drain or a suitable drainage facility.    

    Press the pump pad of the unit to activated the pump

    operation. When the bucket is full the pump starts to work.

    NOTE: The pump may cause big noise when it starts to 

                work for 3~5 minutes. It is a normal phenomenon.

    Make sure the hose is secure so there are no leaks.

    Direct the hose toward the drain,making sure that there 

    are no kinks that will stop the warter flowing.

    Place the end of the hose into the drain and make sure

    the end of the hose is level or down to let the water flow

    smoothly.Do never let it up.

    Select the desired humidity setting and fan speed on the 

    unit for pump draining to start. 

Pump drain

hose

Pump drain

hose outlet

NOTE: The pump operation on light blinks at 1Hz when the 

pump is operational failure. Please turn off the unit and plug 

the power cord out. Check the following things:

    Cleaning the filter of the pump.

    -Remove the bucket from the unit, take down the pump 

     and clean the filter of the pump (See Fig.12). 

    

Filter of the pump

    Check that the pump drain hose does not link or block.  

        

Fig.12

    Empty the water of the bucket.

    Reinstall the pump hose if it drops and reinstall the bucket 

    properly. Turn on the unit. If the error repeats, call for service. 

    

    

    

    

    

OPERATING  THE  UNIT

NOTE: Do not use this operation when the outdoor temperature

O

O

is equal to or less than 0 C (32 F), otherwise water is become

ice that will cause the water hose blocked up and the unit failure. 

Make sure to empty the bucket once a week when using

the pump draining feature. When the pump draining feature is 

not being used, remove the pump drain hose from the outlet.

2,Take the pump 

drain hose out

1,Press the pump drain

hose outlet in

   Press the pump drain hose outlet in and take the pump drain hose 

   out from it (See Fig.13). Make sure do not let the water in the pump 

   hose drip to the floor.   

        

Fig.11

Reinstall the

plastic cover

Fig.13

9

Female threaded

end

Содержание GIADB40X6PW

Страница 1: ...OWNER S MANUAL DEHUMIDIFIER X6WE GIADB40X6PW GIADB50X6PW ENGLSIH Thanks for choossing our product Please read carefully this manual before using the product...

Страница 2: ...user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the use...

Страница 3: ...ck of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play the applianc...

Страница 4: ...d Do not place the unit near a heat source Before cleaning turn off the power and unplug the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc CAUTION...

Страница 5: ...echnician Do not place flower vases or other water container on top of the unit The manufactures nameplate is located on the rear panel of the unit and contains electrical and other technical data spe...

Страница 6: ...e bucket is full the pump starts to work Refer to the next pages for removing the collected water Do not use this operation when the outdoor temperature O O is equel to or less than 0 C 32 F 2 COMFORT...

Страница 7: ...re The system starts to count the time once the fan motor operates The check filter feature can be only activated when the accumulated operation time achieves 250 hours or more The Reset light Clean f...

Страница 8: ...anation purposes only The actual shape of the unit you purchased may be slightly different but the operations and functions are the same Accessories placed in the water bucket of the unit pump drain h...

Страница 9: ...ater in the bucket The unit may tip over and spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there...

Страница 10: ...reinstall the pump hose properly to the unit before replace the bucket into the unit see Fig 8 When you remove the bucket if there is some water in the unit you must dry it When the unit is on if the...

Страница 11: ...wn to let the water flow smoothly Do never let it up Select the desired humidity setting and fan speed on the unit for pump draining to start Pump drain hose Pump drain hose outlet NOTE The pump opera...

Страница 12: ...and cleaning of the dehumidifier Turn the dehumidifier off and remove the plug from the wall outlet before cleaning 1 Clean the Grille and Case Use water and a mild detergent Do not use bleach or abr...

Страница 13: ...other openings are securely closed O O Room temperature is too low below 5 C 41 F There is a kerosene heater or something giving off water vapor in the room The unit makes a loud noise when operating...

Страница 14: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...

Отзывы: