![Ghost Controls Ghost Pro LDM2 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/ghost-controls/ghost-pro-ldm2/ghost-pro-ldm2_installation-and-owners-manual_2220511055.webp)
55
P U S H - T O - O P E N
PROGRAMMING THE OPEN LIMIT: PUSH-TO-OPEN
The
OPEN
limit is when the operator is extended and the gate is in the closed position.
IMPORTANT
ONLY THE OPERATOR ARMS’ EXTENDED LIMIT IS ADJUSTABLE AND CAN BE SET WITH THE CONTROL
BOARD. THE ARMS’ RETRACTED POSITION IS FIXED AND IS NOT ELECTRONICALLY ADJUSTABLE.
THE CLOSED POSITION IS SET BY HARDWARE MOUNTING ONLY. Please refer to the hardware installation to
make sure the retracted position is properly set/installed.
Installation Type
Retracted Position
Extended Position
Push-To-Open
Gate at the fully
CLOSED
position (not
electronically adjustable)
Gate at the
OPEN
position (electroni-
cally adjustable)
TURN THE CONTROL BOX ON
STEP 18.
Setting the open limit.
A. Locate the 2nd SET limit settings on the control board and press and
hold the
JOG CLOSE
button for the second gate until the gate
reaches the
desired closed position. The gate can move only if
pressure is maintained. Releasing the
JOG
button will stop the
gate immediately. Once the 2nd set is in the desired closed position
then repeat for
the 1st gate with the
1st SET limit settings
JOG CLOSE
button.
B. Both
JOG
OPEN
or
JOG CLOSE
buttons are needed to ‘fine’ tune your
desired OPEN position.
STEP 19.
Press and hold the 1st set limit button on the control panel until it beeps, then release.
Then Press and hold the 2nd set limit button until it beeps, then release
STEP 20.
Press the transmitter button to activate the gates and let the gate close fully you should
hear a single beep.
When the gate reaches its
CLOSED position, the control board will sound a single beep, confirming the CLOSED
limit has been set.
A.
Confirm the newly programmed OPEN limit by pressing the remote transmitter button to activate the gate and confirm
the closed position has been set correctly. This limit is stored and remembered even when all of the power sources are
removed.
B. Repeat STEPS 16-18 if needed to change your desired OPEN position.
C. Test your system with the remote transmitter to make sure it opens and closes without errors.
2ND SET LIMIT SETTINGS