Learning Keypad From Working Remote
Step Button(s) Sequence to Press
LED/Alarm After
Pressing
Description
5
Press and Release
This tells the keypad that you have
completed entering the special code
to enable this feature.
6
Press and Release SEND
Completes the programming
sequence for this feature and
exits the keypad back to normal
operation.
If you need to change your Master Pin that allows access to all programming features, follow the process below.
GHOST CONTROLS
®
recommends that you keep this master pin secure from children or guests.
Change Master Pin
Step Button(s) Sequence to Press
LED/Alarm After
Pressing
Description
1
Press and Release
This tells the keypad that you are
going into programming mode.
2
Enter
Old (Current)
Master Pin
Completing this step actually
allows you into programming mode.
Without the correct Master Pin,
then you will not be able to proceed
further.
3
Press and Release
This tells the keypad that you are
going to do program a special feature
into the keypad.
4
Enter 01
Code 01 tells the keypad that you
want it to change the master pin.
5
Press and Release
This tells the keypad that you have
completed entering the special code
to enable this feature.
6
Enter
New (Desired)
Master Pin
This is the new 4 digit Master
Pin that you will use for all future
programming of the keypad.
7
Press and Release SEND
Completes the programming
sequence for this feature and
exits the keypad back to normal
operation.
Adding a Permanent Access PIN allows unlimited access to your property. This PIN is not the same as the
Master PIN because it will not allow the keypad to be programmed or special features to be enabled or disabled.
GHOST CONTROLS
®
recommends that all family members use a Permanent Access PIN instead of the
Master PIN for normal operation.
Add a New Permanent Access Pin (Access Pin allows user to control gate opener system by using keypad.)
Step Button(s) Sequence to Press
LED/Alarm After
Pressing
Description
1
Press and Release
Puts the Keypad into Programming Mode.
Add a New Permanent Access Pin (Access Pin allows user to control gate opener system by using keypad.)
Step Button(s) Sequence to Press
LED/Alarm After
Pressing
Description
2
Enter
Master Pin
Completing this step actually allows you
into programming mode. Without the
correct Master Pin, then you will not be
able to proceed further.
3
Press and Release
This tells the keypad that you are going
to do program a special feature into the
keypad.
4
Enter 02
Code 02 tells the keypad that you want
it to learn a new Four Digit Permanent
Access Pin to allow access to your
property.
5
Press and Release
This tells the keypad that you have
completed entering the special code to
enable this feature.
6
Enter
New (Desired)
Permanent Access
Pin (4 digits)
This New Four Digit Permanent Access
Pin is now programmed into the keypad.
7
Press and Release
This confirms that the four previous
numbers you entered into keypad are your
Permanent Access Pin.
8
Press and Release SEND
Completes the programming sequence for
this feature and exits the keypad back to
normal operation.
If you would like to allow access to your property a limited number of times, you can program a temporary
access pin that will automatically be erased after the number of uses has been reached. The following procedure
will allow you to program your keypad to enable this feature.
Add a New Temporary Access Pin-Number of Uses Based (Pin has limited number of uses.)
Step Button(s) Sequence to Press
LED/Alarm After
Pressing
Description
1
Press and Release
Puts the Keypad into Programming
Mode.
2
Enter
Master Pin
,
Completing this step actually allows
you into programming mode. Without
the correct Master Pin, then you will
not be able to proceed further.
3
Press and Release
This tells the keypad that you are going
to do program a special feature into the
keypad.
4
Enter 70
Code 70 tells the keypad that you are
going to be adding a New Temporary
Access Pin that has a limited number
of uses.