WARRANTY

 

Delta  OHM  is  required  to  respond  to  the  "factory  warranty"  only  in  those  cases  provided  by 
Legislative Decree 6 September 2005 - n. 206. Each instrument is sold after rigorous inspections; 
if  any  manufacturing  defect  is  found,  it  is  necessary  to  contact  the  distributor  where  the 
instrument was purchased from. During the warranty period (24 months from the date of invoice) 
any  manufacturing  defects  found  will  be  repaired  free  of  charge.  Misuse,  wear,  neglect,  lack  or 
inefficient maintenance as well as theft and damage during transport are excluded. Warranty does 
not  apply  if  changes,  tampering  or  unauthorized  repairs  are  made  on  the  product.  Solutions, 
probes,  electrodes  and  microphones  are  not  guaranteed  as  the  improper  use,  even  for  a  few 
minutes, may cause irreparable damages. 
Delta  OHM  repairs  the  products  that  show  defects  of  construction  in  accordance  with  the  terms 
and conditions of warranty included in the manual of the product. For any dispute, the competent 
court is the Court of Padua. The Italian law and the “Convention on Contracts for the International 
Sales of Goods” apply. 

TECHNICAL INFORMATION

 

The quality level of our instruments is the result of the continuous product development. This may 
lead to differences between the information reported in the manual and the instrument you have 
purchased. In case of discrepancies and/or inconsistencies, please write to [email protected]
Delta  OHM  reserves  the  right  to  change  technical  specifications  and  dimensions  to  fit  the 
product requirements without prior notice. 

DISPOSAL INFORMATION

 

 

Electrical  and  electronic  equipment  marked  with  specific  symbol  in  compliance 
with 2012/19/EU Directive must be disposed of separately from household waste. 
European  users  can  hand  them  over  to  the  dealer  or  to  the  manufacturer  when 
purchasing  a  new  electrical  and  electronic  equipment,  or  to  a  WEEE  collection 
point designated by local authorities. Illegal disposal is punished by law. 

Disposing  of  electrical  and  electronic  equipment  separately  from  normal  waste  helps  to 
preserve natural resources and allows materials to be  recycled in an  environmentally friendly 
way without risks to human health. 
 
 
 
 
 
 
 
 
 

RoHS

 

 
 

V2.0 

11/2022 

 

 

Содержание DeltaOHM LPUVA02

Страница 1: ...Operating manual UVA Radiometer LPUVA02 www deltaohm com English Keep for future reference...

Страница 2: ...ON 5 4 ELECTRICAL CONNECTIONS 8 4 1 LPUVA02 CONNECTIONS 8 4 2 LPUVA02AC CONNECTIONS 9 4 3 LPUVA02AV CONNECTIONS 9 5 MEASUREMENT 10 5 1 LPUVA02 10 5 2 LPUVA02AC 10 5 3 LPUVA02AV 10 6 MAINTENANCE 11 7 T...

Страница 3: ...VOLTAGE output to be de fined when ordering 0 200 W m2 Each radiometer is individually calibrated at the factory and is distinguished by its own calibration factor The calibration is performed by com...

Страница 4: ...ined thanks to the par ticular shape of the diffuser and of the housing The deviation between the theoretical response and the measured one is shown in the Fig 2 2 Angle Fig 2 2 The excellent relation...

Страница 5: ...a coin 3 Remove the cartridge perforated cap 4 Open the sachet containing silica gel supplied with the radiometer 5 Fill the cartridge with the silica gel crystals 6 Close the cartridge with its own c...

Страница 6: ...lf For fixing use the holes on the radiometer body remove the shade disk to access the holes and reposition it after mounting or the suitable accessories see the fig ures below In order to allow an ac...

Страница 7: ...LPUVA02 7 V2 0 HD2003 79K HD2003 77C HD2003 83 HD2003 83 1 HD2003 85K Fig 3 3 fixing accessories...

Страница 8: ...to the connector 4 1 LPUVA02 CONNECTIONS The radiometer LPUVA02 is passive and does not require power supply It is to be connected either to a millivoltmeter or to a data acquisition system Typically...

Страница 9: ...rdered output and requires external power supply 10 30 Vdc for 0 1 V and 0 5 V outputs 15 30 Vdc for 0 10 V output It is to be connected to a power sup ply and an instrument with voltage input as show...

Страница 10: ...PUVA02AC The 4 20 mA output signal corresponds to 0 200 W m2 irradiance range The irradiance Ee is obtained by measuring with a multimeter the current Iout absorbed by the sensor and applying the foll...

Страница 11: ...is case the performed reading is highly over estimated To minimize the condensation the radiometer is provided with a car tridge containing dessicant material silica gel The efficiency of the silica g...

Страница 12: ...93 nm 1 10 320 nm 400 nm 1 100 Peak 365 nm Response time 0 5 s 95 Output LPUVA02 V Wm 2 LPUVA02AC 4 20 mA LPUVA02AV 0 1 0 5 0 10 V depending on the model Power supply 10 30 Vdc 15 30 Vdc only for 0 10...

Страница 13: ...safety can be ensured only if all standard safety measures as well as the specific measures described in this manual are followed Do not use the instruments in places where there are Corrosive or flam...

Страница 14: ...the radiometer on 40 mm clamping To install the radiometer on a transverse mast LPS6 Kit for the installation of the radiometer The kit includes 750 mm mast base fitting graduated support plate brack...

Страница 15: ......

Страница 16: ...rranty included in the manual of the product For any dispute the competent court is the Court of Padua The Italian law and the Convention on Contracts for the International Sales of Goods apply TECHNI...

Отзывы: