ELECTRICAL CONNECTIONS 

LPPYRA03

LPPYRA03AC

  and 

LPPYRA03AV

  have  a  4-pole  connector  and  use  the 

CPM12AA4...

 

optional

  cables,  with  4-pole  connector  on  one  side  and  open  wires  on 

the other side. 

LPPYRA03S

 and 

LPPYRA03S12

 have a 8-pole connector and use the 

CPM12-8D...

 

optional

 cables, with 8-pole connector on one side and open wires on the other side. 

The  metallic  housing  of  the  pyranometer  should  preferably  be 
grounded ( ) locally. In this case, do not connect the wire of the 
cable corresponding to the housing to prevent ground loops. 

Only if it is not possible to ground locally the metallic case of the 
pyranometer, connect the wire of the cable corresponding to the 
housing  to  ground  ( ). 

Note: in LPPYRA03AV the housing is not con-

nected to the connector. 

Inside the housing there is a surge protector connected between the 
housing itself and the electronic circuit (powered models) or the ca-
ble shield (passive model). Grounding the housing allows the correct 
protection function (in particular against lightning) of the surge pro-
tector. 

4.1

 

LPPYRA03

 CONNECTIONS

 

The pyranometer LPPYRA03 is passive and does not require power supply. It  is to be 
connected either to a millivoltmeter or to a data acquisition system. Typically, the py-
ranometer output signal does not exceed 20 mV. In order to better exploit the pyra-
nometer features, the readout instrument should have 1 

µ

V resolution. 

Connector 

Function 

Color 

+Vout 

Red 

-Vout 

Blue 

Housing (C) 

White 

Cable shield (SH) 

Black 

1

2

3

4

+Vout

-Vout

SH

C

 

Fig. 4.1: LPPYRA03 connections 

 

CPM12AA4… cable 

Pyranometer M12 

male connector 

Datalogger or 

converter/amplifier 

with 

V

 or 

mA

 output 

Connect to ground only if it is not possible to 
ground locally the housing of the pyranometer 

To circuit 

Housing 

Surge 
protector 

Содержание Delta OHM LPPYRA03

Страница 1: ...Operating manual Pyranometer LPPYRA03 www deltaohm com English Keep for future reference...

Страница 2: ...ECTIONS 10 4 5 LPPYRA03S12 CONNECTIONS 11 4 6 LPPYRA03ACS CONNECTIONS 12 5 MEASUREMENT IN THE MODELS WITH ANALOG OUTPUT 13 5 1 LPPYRA03 13 5 2 LPPYRA03AC S 13 5 3 LPPYRA03AV 13 6 RS485 MODBUS RTU OUTP...

Страница 3: ...ts D09847 and HD31 by using VP 472 SICRAM module LPPYRA03AC ACTIVE with 4 20 mA CURRENT output 0 2000 W m2 LPPYRA03ACS ACTIVE with 4 20 mA CURRENT output 0 2000 W m2 and RS485 Modbus RTU output LPPYRA...

Страница 4: ...o the Seebeck effect the difference of temperature between hot and cold junction is converted into a Difference of Potential In order to grant the thermopile a proper thermal insulation from the wind...

Страница 5: ...is used without the optional shade disk it must be positioned so that its connector is pointed to the North Pole if the instrument is used in the Northern Hemisphere and to the South Pole if used in...

Страница 6: ...A03 AC S LPPYRA03S12 LPS2 LPPYRA03 LPS2 LPPYRA03 HD2003 77 40 LPSP2 500 mm 16 mm 40 mm LPPYRA03AC LPPYRA03AV LPPYRA03 AC S LPPYRA03S12 HD2003 77 40 D HD9007 HD9007T29 1 C A B TP32MTT 03 C 80 MAX int M...

Страница 7: ...LPPYRA03 7 V2 8 Fig 3 3 fixing accessories...

Страница 8: ...g there is a surge protector connected between the housing itself and the electronic circuit powered models or the ca ble shield passive model Grounding the housing allows the correct protection funct...

Страница 9: ...ordered output and requires external power supply 10 30 Vdc for 0 1 V and 0 5 V outputs 15 30 Vdc for 0 10 V output It is to be connected to a power sup ply and an instrument with voltage input as sh...

Страница 10: ...S485 A Brown 5 RS485 B White 6 Housing Cable shield SH Black 7 Not connected 8 Not connected Shield Shield Lmax 1200m B A 1 2 3 4 5 6 7 8 B A SGND Vdc GND GND Vdc A B SH R 220 T R 220 T Fig 4 4 LPPYRA...

Страница 11: ...7 8 GND Vdc SDI 12 SDI 12 BUS Vdc GND SH Fig 4 5 LPPYRA03S12 connections More SDI 12 sensors can be connected in parallel The distance between a sensor and the acquisition system data logger should n...

Страница 12: ...1 Power supply negative GND Blue 2 Power supply positive Vdc Red 3 Digital and analog ground SGND Black 4 RS485 A Brown 5 RS485 B White 6 Housing Cable shield SH Black thick wire 7 Analog output posit...

Страница 13: ...tivity of the pyranometer expressed in V Wm 2 5 2 LPPYRA03AC S The 4 20 mA output signal corresponds to the 0 2000 W m2 irradiance range The irradiance Ee is obtained by measuring with a multimeter th...

Страница 14: ...y to install the related USB drivers in the PC NOTES ON THE INSTALLATION OF UNSIGNED USB DRIVER before installing unsigned USB driver into operating systems starting from Windows 7 it is necessary to...

Страница 15: ...ta bits no parity 2 stop bits n 2 8 E 1 8 data bits even parity 1 stop bit n 3 8 E 2 8 data bits even parity 2 stop bits n 4 8 O 1 8 data bits odd parity 1 stop bit n 5 8 O 2 8 data bits odd parity 2...

Страница 16: ...4 3 Status register bit0 1 solar radiation measurement error bit2 1 configuration data error bit3 1 program memory error 16 bit Integer 5 4 Average values of the last 4 measurements 16 bit Integer 6...

Страница 17: ...ing table The following table reports the SDI 12 commands available For consistency with SDI 12 standard documentation the instrument address is indicated in the table with the letter a SDI 12 Command...

Страница 18: ...al temperature in the set unit of measurement default C Example of response 0 0 228 7 3 294 25 0 probe address 0 content of the status register 0 irradiance 228 7 W m2 signal internal level 3 294 mV i...

Страница 19: ...execute the measurement aD0 a v v CR LF with v v signal internal level in mV Example of response 0 3 294 probe address 0 signal internal level 3 294 mV Reads the measurement In addition to the above m...

Страница 20: ...end the command aXSCAL USER ON note a instrument address 2 Send the command aXSCFD to set C or aXSCFE to set F 3 Send the command aXSCAL END For more information about the SDI 12 protocol visit the we...

Страница 21: ...tly the more the dome will be kept clean the more measure ments will be accurate You can wash it using water and standard papers for lens If necessary use pure ETHYL alcohol After using alcohol clean...

Страница 22: ...0 A for the version LPPYRA03S12 Connection 4 or 8 pole M12 connector depending on the model Dimensions Fig 3 1 Weight 270 g approx passive version 400 g approx active versions Weights without optional...

Страница 23: ...well as the specific measures described in this manual are followed The instrument proper operation and operating safety can be ensured only in the cli matic conditions specified in this manual Do not...

Страница 24: ...AA4 5 or 10 m CPM12AA4 10 For LPPYRA03 LPPYRA03AC and LPPYRA03AV CPM12 8D Cable with 8 pole M12 connector on one end open wires on the other end Length 2 m CPM12 8D 2 5 m CPM12 8D 5 or 10 m CPM12 8D 1...

Страница 25: ...LPPYRA03 25 V2 8 NOTES...

Страница 26: ...LPPYRA03 26 V2 8 NOTES...

Страница 27: ......

Страница 28: ...anty included in the manual of the product For any dispute the competent court is the Court of Padua The Italian law and the Convention on Contracts for the International Sales of Goods apply TECHNICA...

Отзывы: