background image

www.ghibliwirbel.com 

Professional Cleaning Machines Since 1968

ENGLISH 

- 1

Technical feaTures

Tension .................................. See data plate

Motor power .......................................800 W

Noise level...................................... 62 dB(A)

Depression ................................210 mmH

2

O

Paper bag capacity .................................12 l

Dimensions ............... 390 x 340 x 290H mm

Weight .................................................4.6 kg

Accessories ....................................Ø 32 mm

TYPe Of use

This unit must solely be used to vacuum 

dust, crumbs, etc. as it is designed solely for 

this purpose.

 haZarD:

The manufacturer cannot be held liable 

for any damage caused by improper or 

incorrect use.

any other use relieves the Manufacturer 

from all responsibility of damage caused 

to persons and/or things and renders the 

warranty null and void.

 incOrrecT use

Do not use the unit to:

-  vacuum any type of liquid;

-  vacuum flammable,  explosive,  corrosive 

and toxic substances.

-  vacuum hot substances.

Do not use the unit in explosive atmos-

pheres.

PreParinG The uniT

Checking the filter systems

-   Release the levers (1 Fig.1) and remove

  the cover (2 Fig.2) complete with the mo-

tor unit and cartridge filter (3 Fig.2).

-   Check that the paper filter bag (4 Fig.3) is 

in place inside the device.

-   If the paper filter bag (4 Fig.3) is not 

present, insert it by putting the square 

cardboard stiffener into the slot in the 

drum.

-   Replace the cover and lock it using the 

levers (1 Fig.1).

assembling the pipes

-   Insert the sleeve with bayonet connection 

(5 Fig.4) into the hole (6 Fig.4) in the con-

tainer, aligning the connections present 

in the sleeve with the slots (7 Fig.4) in 

the hole in the container, then rotate the 

sleeve clockwise to lock it.

-  Hook the rigid extensions (8 Fig.5) to the 

ergonomic handle (9 Fig.5) of the flexible 

pipe.

-   Attach the desired accessory (floor tool,

  dusting brush, crevice tool, multi-purpose 

brush etc.) to the suction tube (9 Fig.5)

using the telescopic tube

-  The length of the telescopic tube (20 Fig. 

16) can be adjusted as follows:

-  To lengthen the tube, press down on the 

ring nut (21 Fig. 16) and simultaneously 

extract the top part (22 Fig. 16) of the 

tube. Once the required length has been 

obtained, release the ring nut (21 Fig. 16) 

the tube will lock into the nearest locking 

position;

-  To shorten the telescopic tube, use one 

hand to push the ring nut (21 Fig. 16) 

down and the other to reinsert the top 

tube (22 Fig. 16) into the lower sleeve (23 

Fig. 16).

Multi-purpose brush

The multi-purpose brush should be used as 

follows:

-   To clean hard floors, parquet etc. press 

the lever back (10 Fig.6) to remove the 

bristles from the brush.

-   To vacuum on carpets, rugs etc. press 

the lever forward (10 Fig.6) to retract the 

brush bristles.

Manuale AS2-8050826_1ed_04-2017.indd   1

20/07/17   14:24

Содержание AS 2 MIKROS

Страница 1: ...www ghibliwirbel com Professional Cleaning Machines Since 1968 MIKROS EN Use and Maintenance 80 50 826 ed 10 2018...

Страница 2: ...www ghibliwirbel com Professional Cleaning Machines Since 1968 2 Mod Art Cap ty Vac mba Air flow l s Nr 3 4 5 6 7 8 1 2...

Страница 3: ...erkapasitet Sugekapasitet Luftmengde Matrikkelnr Elektriske egenskaper DK Fabrikant Model Artikel Beholdervolumen Sugeeffekt Luftm ngde Matrikelnummer El specifikationer SV Tillverkare Modell Artikel...

Страница 4: ...www ghibliwirbel com Professional Cleaning Machines Since 1968 4...

Страница 5: ...www ghibliwirbel com Professional Cleaning Machines Since 1968 5...

Страница 6: ......

Страница 7: ...www ghibliwirbel com Professional Cleaning Machines Since 1968 7 EN English ENGLISH 1 Translation of original instructions...

Страница 8: ...www ghibliwirbel com Professional Cleaning Machines Since 1968 8...

Страница 9: ...d stiffener into the slot in the drum Replace the cover and lock it using the levers 1 Fig 1 Assembling the pipes Insert the sleeve with bayonet connection 5 Fig 4 into the hole 6 Fig 4 in the con tai...

Страница 10: ...ag Release the levers 1 Fig 1 and remove the cover 2 Fig 2 complete with the mo tor and the cartridge filter 3 Fig 2 Remove the paper filter bag 4 Fig 3 and replace as indicated above Reassemble every...

Страница 11: ...ch is not pressed Plug is not inserted Power cut Press the switch Insert the plug into the socket Check the power line Unsatisfactory suction Paper bag is full Filter components are clogged Clogged ac...