![Ghibli & Wirbel 16801210001 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/ghibli-and-wirbel/16801210001/16801210001_use-and-maintenance_2220292013.webp)
www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
ENGLISH
- 5
Periodic cleaning
Draining and rinsing the system
- Unhook the levers (8 Fig. 5) and remove
the head (9 Fig. 6).
- Fill the tank with about 3 litres of deminer
-
alised water.
- Reassemble the head (6 Fig. 6) and lock
it in with the levers (8 Fig. 5).
- Switch on the device as indicated in the
relevant paragraph.
- To rinse the system, keep the lever (16
Fig. 11) on the nozzle pressed for about
2 minutes.
- At the end, switch off the device as indi
-
cated in the relevant paragraph.
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
The sanitiser isn’t working.
Switch not pressed.
Press the switch to “ON”.
Plug not inserted.
Insert the plug into the sock
-
et.
No current.
Check the power supply
line.
The sanitiser is on but does
not dispense the sanitising
solution.
The system circuit is empty.
Press the lever and wait for
the internal machine circuit
to fill up to be available for
use with the dispensing
nozzle.
The tank is empty.
Fill the tank.
Pump fault.
Contact an authorised ser
-
vice centre.
Manuale SaniPro_8050862_2ed_09-2020.indd 5
Manuale SaniPro_8050862_2ed_09-2020.indd 5
15/09/2020 13:11:33
15/09/2020 13:11:33