PN ?????? Rev A
DirectCommand
TM
Spreader
PN 2006314 Rev B
2
Fan Speed Calibration
pulses/revolution of spinner
PWM Gain
decrease to slow response time
PWM Frequency
frequency valve is pulsed at, settings come from valve
manufacturer, typical range = 100-125 Hz
Zero RPM Offset
duty cycle used to start rotating the spinner, if setting is
too high spinner will not stop rotating, default = 30
Automatic Control
select to control the spinner speed
Spinner Tab
PWM Frequency
frequency valve is pulsed at, settings come from
manufacturer, typical range: 100-125 Hz
PWM Gain
decrease to slow response time
Zero Flow Offset
duty cycle used to start moving conveyor, if setting is
too high conveyor will not turn off, default = 30
Allowable Error
error allowed before making rate control adjustments
Shaft Speed Calibration
pulses/revolution of metering shaft
Max Speed
maximum RPM of product conveyor
PWM Valve