Page 12
Important Notice
!
After the Mains supply has been connected by inserting the CEE plug in the
appropriate socket or turning on the main switch, confirm that the phase rotation
is correct by checking that the door opens when the OPEN push button is
operated.
If the door closes when operating the OPEN push button reverse two phases
at the terminal X1.
PHASE ROTATION
DANGER! To the life and health through electric shock.
Before changing phase rotation the mains supply must be switched OFF.
Three-phase 3 x400 V AC, N, PE
Star connection
Three-phase 3 x230 V AC, PE
Delta connection
Single-phase 1x230 V AC, N, PE
symmetrical winding
Single-phase 1x230 V AC, N, PE
asymmetrical winding
Important note!
For 3x400V AC PE no
neutral, the brake
rectifier must be
connected between
terminal V and star-
point terminal.
brown
brown
supply for
brake
rectifier
blue
supply for
brake
rectifier
MOTOR CONNECTION (internal wiring)
blue
On several ELEKTROMATEN
®
the connection U1 und V1 on the motor-plug are
interchanged.