background image

 

  

 

 

Table of contents 
1

 

General safety information .............................................................................................. 4

 

2

 

Technical Data ................................................................................................................ 5

 

3

 

Mechanical installation .................................................................................................... 6

 

4

 

Electrical installation ..................................................................................................... 10

 

5

 

Limit switch adjustment ................................................................................................. 11

 

6

 

Motor connection .......................................................................................................... 12

 

7

 

Limit switch connection ................................................................................................. 12

 

8

 

Emergency manual operation SK (rapid hand chain operator) ...................................... 13

 

9

 

Completing commissioning / inspection ......................................................................... 14

 

10

 

Declaration of incorporation / conformance ................................................................... 15

 

 

 

 

 

  Symbols 

 

Warning - Potential injury or danger to life! 

 

Warning - Danger to life from electric current! 

 

Note - Important information! 

▶ 

Requirement - Required action! 

Schematic representations are based on product examples. Deviations from delivered 
products are possible. 

Содержание ELEKTROMAT SE 7.32 WS-25,40

Страница 1: ...Installation Instructions ELEKTROMAT SE 7 32 WS 25 40 RP07 32WRD Model 10002245 10006 en Status 05 07 2016...

Страница 2: ...2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom sales gfa elektromaten co uk www gfa elektromaten co uk...

Страница 3: ...2 8 Emergency manual operation SK rapid hand chain operator 13 9 Completing commissioning inspection 14 10 Declaration of incorporation conformance 15 Symbols Warning Potential injury or danger to lif...

Страница 4: ...l be rendered null and void Safety information Installation and initial operation tasks are to be performed by trained skilled fitters only Only trained electrical craftsmen are permitted to work on e...

Страница 5: ...eight 4000 N Supply voltage 1N 230 V Operating current 3 90 A Operating frequency 50 Hz Power factor cos 0 99 Maximum movement per hour 12 h 1 Class of protection IP 65 Limit switch range maximum revo...

Страница 6: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Страница 7: ...7 Mounting Eight threads are provided for mounting Use at least 2 of these Keys are used to connect to the door shaft Use a key that is at least as long as the hollow shaft 8 x M8x16 BAGAD01001_Z002...

Страница 8: ...manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thor...

Страница 9: ...BAGAE01003_Z003 Tighten all connection elements M8 to 25 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE01006_Z002 25 Nm Secure the keys versio...

Страница 10: ...are de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Inse...

Страница 11: ...11 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel...

Страница 12: ...n C1 Capacitor M1 Motor X13 Motor plug 7 Limit switch connection F10 Thermal contact S10 Manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circ...

Страница 13: ...ltage Electrical operation is no longer possible Warning Injury through improper operation Disconnect the voltage Adopt a secure position For drives that have a brake emergency manual operation should...

Страница 14: ...on cables and cabling for damage or crushing Check that the screw connections and plug connections are fitted properly with a good electric contact Emergency manual operation Check the function with t...

Страница 15: ...ronments Electromagnetic compatibility EMC Part 6 3 Generic standard Emission standard for residential commercial and light industrial environments We undertake to transmit in response to a reasoned r...

Страница 16: ...16...

Отзывы: