background image

 

18 

 

11

 

Declaration of incorporation / Declaration of conformity 

Declaration of incorporation  

within the meaning of Machinery Directive 2006/42/EC 
for partly completed machinery, Appendix II Part B 
 

Declaration of conformity 

within the meaning of EMC Directive 2014/30/EU 
within the meaning of RoHS Directive 2011/65/EU 

We,  
GfA ELEKTROMATEN GmbH & Co. KG 
declare under our sole responsibility that the 
following product complies with the above 
directives and is only intended for installation in a 
door system. 
 
Drive unit 

SE 15.48-25,40 

Part no.: 10004112 10006 
 
 
We undertake to transmit in response to a 
reasoned request by the appropriate regulatory 
authorities the special documents on the partly 
completed machinery. 
 
This product must only be put into operation 
when it has been determined that the complete 
machine/system in which it has been installed 
complies with the provisions of the above-
mentioned directives. 
 
Authorised representative to compile the 
technical documents is the undersigned. 
 
Düsseldorf, 10.08.2018 
 
Stephan Kleine 
CEO 
 

 

Signature 
 
 

  The following requirements from Appendix I of 

the Machinery Directive 2006/42/EC are met: 
1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2, 
1.3.3, 1.3.9, 1.5.1, 1.5.2, 1.5.4, 1.5.6, 1.5.7, 
1.5.8, 1.5.9, 1.5.10, 1.5.11, 1.5.13, 1.6.1, 1.6.2, 
1.6.4, 1.7.2, 1.7.3, 1.7.4.3. 
 
Standards applied: 
EN 12453:2001 
Industrial, commercial and garage doors and 
gates - Safety in use of power operated doors - 
Requirements 
 
EN 12604:2017 
Industrial, commercial and garage doors and 
gates - Mechanical aspects - Requirements 
 
EN 60335-1:2012 
Household and similar electrical appliances - 
Safety - Part 1: General requirements 
 
EN 61000-6-2:2005 
Electromagnetic compatibility (EMC) Part 6-2 
Generic standards – Immunity standard for 
industrial environments 
 
EN 61000-6-3:2007 
Electromagnetic compatibility (EMC) Part 6-3 
Generic standards – Emission standard for 
residential, commercial and light-industrial 
environments 

 

 

 

  
 

Содержание ELEKTROMAT SE 15.48-25,40

Страница 1: ...Installation Instructions ELEKTROMAT SE 15 48 25 40 NOT DEFINED Model 10004112 10006 en Status 25 11 2019...

Страница 2: ...2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom sales gfa elektromaten co uk www gfa elektromaten co uk...

Страница 3: ...h connection 13 9 Emergency manual operation hand chain operator 14 10 Completing commissioning inspection 16 11 Declaration of incorporation Declaration of conformity 18 Symbols Warning Potential inj...

Страница 4: ...l be rendered null and void Safety information Installation and initial operation tasks are to be performed by trained skilled fitters only Only trained electrical craftsmen are permitted to work on e...

Страница 5: ...erating current 1 90 A Operating frequency 50 Hz Power factor cos 0 54 Maximum movement per hour 12 h 1 Hand forces 87 N Class of protection IP 65 Limit switch range maximum revolutions of output shaf...

Страница 6: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Страница 7: ...7 Mounting Eight threads are provided for mounting A key is used to connect to the door shaft Use a key that is at least as long as the hollow shaft BAGAD02003_Z002...

Страница 8: ...or manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Th...

Страница 9: ...BAGAE02005_Z002 Tighten all connection elements M8 to 25 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE02009_Z002 25 Nm Secure the keys versio...

Страница 10: ...energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the...

Страница 11: ...11 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel...

Страница 12: ...12 6 Motor connection G1 Rectifier EGR M1 Motor X13 Motor plug Y1 Brake 7 Alternative motor connection G1 Rectifier EGR M1 Motor X13 Motor plug Y1 Brake...

Страница 13: ...13 8 Limit switch connection F10 Thermal contact S10 Manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply network...

Страница 14: ...y manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453...

Страница 15: ...15 Switch on by pulling the red handle Open or close by pulling the chain Switch off by pulling the green handle...

Страница 16: ...unts screws locking rings etc are secure and in proper condition Electrical wiring Check the connection cables and cabling for damage or crushing Check that the screw connections and plug connections...

Страница 17: ...er to life Lifecycle brake change complete brake unit at Operation with mains supply after 250 000 cycles Operation with Inverter after 1 000 000 cycles In an environment that can affect the coefficie...

Страница 18: ...complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The fo...

Страница 19: ...19...

Страница 20: ...20...