background image

 

  

 

 

Installation 
 

 

WARNING

 

 

Danger due to uncontrolled door movement. 

  Carry out the following work only when the power supply is switched off. 

  Lock the door to through traffic while working. 

 

Installation on the door 

 

Remove the cover from the door leaf box. 

 

Screw the door leaf box onto the door 

leaf. 

 

145

4

0

mi

n

.

 60

 

NOTICE 

 

Observe the following notes for selecting the place of installation: 

  Mount the WSD door-module as close to 

the door control as possible. 

  The WSD door-module should not be 

obscured by obstacles at stop and 
during movement (holes in the ground, 
crane runways, concrete or steel pillars, 
shelves, etc.) 

 

 

  Radio systems may be affected by other 

radio systems or EMC radiation. In case 
of frequent interferences, changing the 
channel may help. Should interferences 
occur more frequently despite the 
channel change, the system must be 
replaced by a wired system. 

 

 

 

 

Содержание 30005154

Страница 1: ...f Installation Instructions WSD door module 2 4 GHz Model 30005154 en 51171746_00002_a Status 11 2019...

Страница 2: ...ical experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Intended use T...

Страница 3: ...ollowing notes for selecting the place of installation Mount the WSD door module as close to the door control as possible The WSD door module should not be obscured by obstacles at stop and during mov...

Страница 4: ...itch Q1 Q2 2 switches with cross fault monitoring One switch with cross fault monitoring on on One switch without cross fault monitoring on off Without switch on off 2 switches without cross fault mon...

Страница 5: ...capacity and the battery service life is reduced Route excess cable over the battery Avoid excess cable length in the door leaf boxes by laying a loop in the profile System overview The available conn...

Страница 6: ...5 cable glands M16 x 1 5 i NOTE Please note that only switches with performance level c PLc comply with the current DIN EN 12453 standard Connection diagram System 1 OSE ST3 ST1 2 1 X2 X1 2 1 2 1 Sla...

Страница 7: ...nection diagram System 1 1k2 and 8k2 2 1 X2 2 1 KL1 X1 2 1 Slack rope switch Pass door switch Connection diagram System 2 OSE X1 2 1 ST3 ST2 ST1 ST3 ST2 ST1 2 1 2 1 X2 X1 Slack rope switch Pass door s...

Страница 8: ...an 1 year Replace the batteries during the annual maintenance of the door system DANGER Do not attempt to charge the battery Do not short circuit the battery Do not disassemble or deform the battery D...

Страница 9: ...trol Also follow the instructions for the door control Assign a different radio channel to each door Note the channels in the door control housing to facilitate maintenance Also observe the notes for...

Страница 10: ...s on the door control TS 971 SW 1 8 39 channels TS 971 SW 1 8 20 channels Also note the following frequency table min 75m Ch5 Ch5 m in 75 m Channel Frequency MHz Channel Frequency MHz Channel Frequenc...

Страница 11: ...enough postage to the package and mark it as old devices i NOTE Lithium metal battery The product contains an individually packed lithium metal battery According to the safety data sheet the lithium c...

Страница 12: ...in a door system WSD door module Part no 30005154 D sseldorf 04 11 2019 Stephan Kleine CEO Signature Standards applied EN 60335 2 103 2015 Household and similar electrical appliances Safety Part 2 10...