Technical data of the drive unit 

 

Explosion protection 

II 2G  Ex db eb ib h IIC T3 Gb 

II 2D  Ex tb h IIIC 190°C Db 

Output torque 

400 

Nm 

Output speed 

15 

rpm 

Output / hollow shaft 

40,00 

mm 

Locking torque 

760 

Nm 

Safety brake (testing centre / approval number) 

14-003612-PR03 

 

Supply voltage 

3~ 400 

Operating current 

2,70 

Operating frequency 

50 

Hz 

Power factor cos 

φ

 

0,76 

 

Maximum movements per hour 

20 

h

-1

 

Manual force, emergency manual operation 

136 

Protection class 

IP 65 

 

Limit switch range 

(maximum revolutions of the output / hollow shaft) 

20 

 

Temperature range 

-10 / +40 

°C 

Installation height 

< 1000 

 

 
Components used 

 

Gearbox 

SG 85F 92.T3 

Motor 

F80-2GD CTV C4 

Terminal box 

8146/1041 

Limit switch / emergency manual operation switch 

07-2511 

 

 

 

Содержание 10002592 00013

Страница 1: ...f Installation Instructions ELEKTROMAT SI 40 15 40 00 Ex Model 10002592 00013 en Status 22 11 2019...

Страница 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Страница 3: ...tion of the motor 17 11 Limit switch connection 17 12 Emergency manual operation emergency hand crank 18 13 Completion of commissioning testing operation 20 14 Declaration of conformity Motor 24 15 De...

Страница 4: ...sks are to be performed by skilled personnel only Only trained electrical craftsmen are permitted to work on electrical equipment They must assess the tasks assigned to them recognise potential danger...

Страница 5: ...PR03 Supply voltage 3 400 V Operating current 2 70 A Operating frequency 50 Hz Power factor cos 0 76 Maximum movements per hour 20 h 1 Manual force emergency manual operation 136 N Protection class IP...

Страница 6: ...85F 92 T3 Manufacturer GfA Explosion protection II 2G Ex h IIC T3 Gb II 2D Ex h IIIC 190 C Db Max output torque 400 Nm Max output speed 19 rpm Shaft centre distance 85 mm Transmission ratio 1 92 Tempe...

Страница 7: ...IP65 T 125 C Certificate of verification TUV IT 14ATEX021X Supply voltage 230 400 10 V Operating current 4 68 2 70 A Operating frequency 50 Hz Power 1 1 kW Power factor cos 0 76 Motor speed 1430 rpm M...

Страница 8: ...6 20 40 T5 20 55 C Protection class IP 66 6 Technical data of limit switch emergency manual operation switch Type 07 2511 113061G Manufacturer Bartec Explosion protection II 2G Ex d IIC T6 II 2D Ex tD...

Страница 9: ...walls mountings connection and transmission elements must not be exceeded even for maximum holding or locking torque observe technical data Connection elements Use self locking connection elements wi...

Страница 10: ...10 Permissible mounting positions BAGAC03005_Z001 Mounting 2 elongated holes are provided for mounting BAGAD03001_Z003...

Страница 11: ...her defined The door manufacturer s specifications must also be observed Warning Injury or danger to life possible Use a lifting device with sufficient load carrying capacity for installation tasks Co...

Страница 12: ...ve unit BAGAE3007_Z001 Tighten all connection elements M12 with a torque of 75 Nm Install all further connection elements according to the specifications of the door manufacturer BAGAE03012_Z001 75 Nm...

Страница 13: ...ect the cables mains OFF and check that the supply is off Observe the applicable regulations and standards Ensure proper electrical connection Use suitable tools Carrying out the electrical installati...

Страница 14: ...uit protection is also required Excess current must be set on the basis of the IA IN ratio Completing the electrical installation Install cable entries and or cable glands In order to achieve the requ...

Страница 15: ...by pressing the OPEN push button of the control If the door closes L1 and L2 must be swapped in a de energised state Setting of OPEN final limit position Open to the desired OPEN final limit position...

Страница 16: ...1 EMERGENCY OPEN limit switch is preset by the setting of the OPEN final limit position The door must stop without posing any risks should the rotating direction be incorrect or should there be a faul...

Страница 17: ...M1 Motor 11 Limit switch connection S10 Manual operation X12 Terminal rail S1 Safety open limit switch S2 Safety close limit switch S3 Open limit switch S4 Close limit switch S5 Additional limit swit...

Страница 18: ...the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604...

Страница 19: ...19 Plug in the crank and turn until it engages Open or close by turning the crank After use the crank may be attached to the drive unit Attach as illustrated...

Страница 20: ...ires no maintenance or inspection Warning Danger of the door dropping In the case of a gearbox damage the internal safety brake is triggered to prevent the door from dropping The gearbox stalls Releas...

Страница 21: ...y out functional test only between final limit positions Limit switches Check the final limit positions by opening and closing the door completely The safety zone must not be reached Entire drive unit...

Страница 22: ...ove directive and that no new hazards arise from their assembly The assembled modules are intended only for installation in a door system Drive unit SI 40 15 40 00 Ex Part no 10002592 00013 Consisting...

Страница 23: ...he product according to Directive II 2G Ex h IIC T3 Gb II 2D Ex h IIIC 190 C Db Notified body pursuant to Directive T V Nord Anlagetechnik GmbH Am T V 1 30519 Hannover Deutschland Registration number...

Страница 24: ...24 14 Declaration of conformity Motor...

Страница 25: ...25 15 Declaration of conformity Accessories...

Страница 26: ...26...

Страница 27: ...d complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The...

Страница 28: ...28...

Отзывы: