18
9
Limit switch setting
The limit switch setting defines the final limit positions OPEN and CLOSE.
Requirement
The door should open by pressing the OPEN
push-button of the control. If the door closes,
L1 and L2 must be swapped in a de-
energised state.
Setting of OPEN final limit position
Open to the desired OPEN final limit position
using the OPEN push-button.
Turn the cam of the S3 OPEN limit switch to
the centre of the switch plunger ①.
Tighten the screw of the cam ②.